Conditioning: <strong>pCO</strong> <strong>Standard</strong> chiller + heat pump User Guide ver. 2.9 02/11/99Use guideStatus of the systemThe system can be ON, OFF or in the MANUAL functioning mode.To turn ON the chiller or heat pump and consequently start the regulation process, follow theseindications:• press the ON button (led indicator ON);• be sure that the daily or weekly time-zones control action has been enabled;• for remote on/off be sure that digital input no. 1 is closed;• be sure that - in case of network connection to a supervisory unit - the two units are correclyconnected;• the unit must not be in the manual functioning mode;• there must be NO alarm conditions (eg. flowmeter alarm).If all these conditions occur, the green led will light up.When the system is ON, compressors and fans will be operated on the basis of the valuesmeasured by the temperature and pressure transducers.If one of the above conditions does not occur, the unit will remain in the OFF status.The display and the ON led indicator will inform the User of the status of the entire system: inparticular, the last row of the main mask (which can be accessed by pressing the 'MENU'button) will show one of the following messages:- Unit OnWhen the unit is On, all devices can be operated.The ON/OFF led indicator is On.NOTE: On the MHP unit are available the terminals for connected a remote digital signal forcontrol Summer/Winter: when tehe digital input number 2 is ON the unit is controlledSUMMER, when the digital input number 2 is OFF the unit is controlled WINTER.To verify the distance of the remote digital contacts: the remote digital contacts are connectedon the circuit 24 Vac and the power transformer installed is 50VA. The installation of auxiliaryrelay is the best solution.It is raccomanded, however, to execute the following operations:1) to stop the unit and to attend the stop of motor pump evaporator electrical relay2) to change the function3) to start the unit.- Unit OffWhen the unit is Off, it is not possible to operate the connected devices.The ON/OFF led indicator is Off.- Off status via supervisory unitPag.21/61

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!