Conditioning: <strong>pCO</strong> <strong>Standard</strong> chiller + heat pump User Guide ver. 2.9 02/11/99Configuration GuideNumber of compressorsThe factory-set number of compressors to be controlled is one (default value). Should your unitcomprise two compressors, enter the protected mask (via manufacturer password, see sectionabout masks below) and change the default parameter.The system can control up to 2 compressors (max.) plus their relative capacity-controlledroutines.The capacity-controlled routine can be operated according to two different modes:- DWM COPELAND logic: the capacity-controlled routine occurs when the output is closed;- FEDDERS logic: the capacity-controlled routine occurs when the output is open.Number of fans<strong>pCO</strong> manages 2 fans, one per circuit. The fans will be operated on the basis of the controller'sfunctioning mode, that is Winter or Summer:Summer functioning mode:Fans are operated according to the HIGH PRESSURE values measured by thepressuretransducers. If there are no pressure probes, the fans' activation will depend on the relativecompressors (fan on when compressor on and vice versa).Winter functioning mode:Fans and compressors will be activated and stopped at the same time.During a defrosting cycle the fan of the circuit undergoing defrosting will be stopped.In the event of circuit breakers (fan/flowmeter circuit breaker, etc.) the fans will be stoppedimmediately.Optional devicesYou can enhance the functions of the <strong>pCO</strong> controller by adding a series of optional devices(RS422 serial card, printer cable, clock card) that can be enabled by simply acting on thededicated masks.The RS422 card interfaces <strong>pCO</strong> to a supervisory network that can receive all data and alarmsfrom <strong>pCO</strong>.A dedicated cable will allow you to connect <strong>pCO</strong> to an external printer.Depending on the option selected, you will have to set in the dedicated masks time and date (toenable the clock card) or <strong>pCO</strong>'s identification number (so as to address messages correctlywhen the controller is network-connected into a supervisory/telemaintenance system by meansof the RS422 card).You can get periodic or immediate printouts of the values measured by the probes; in the eventof off-normal conditions, the relative alarm will be immediately printed.Pag.20/61

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!