Cooling & Heating - Andrews Sykes

Cooling & Heating - Andrews Sykes

Cooling & Heating - Andrews Sykes

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Low temperature chillersWhen the need for a low temperature application arises, the <strong>Andrews</strong> <strong>Sykes</strong>range of fast chill units have been developed to provide temperatures below-10ºC. The range comprises of 3 models which can be used in a similarconfiguration to the water cooled PAC units.Each of the models comprises of 2 parts - a room unit, which must beplaced within or ducted into the area that requires cooling, and an externalheat exchanger. The room unit which contains the compressor andevaporator is linked via 2 x 32mm diameter flexible hoses to the external heatexchanger. In their standard configuration these flexible lines are suppliedin lengths of 15 metres and can be extended up to a maximum of up to 30metres.Although larger in size than most PAC units the fast chill units are stillportable and can be put to work quickly and with the minimum amount ofinstallation. Each model incorporates a programmable controller which canoperate within ±0.5ºC.Applications for portable chillers■■ Cold stores■■ Beer cellars■■ Vegetable storage■■ Fresh meat cold room■■ Frozen meat holding room■■ Large volume airconditioning■■ Temporary body storage■■■■■■■■Archive document storageLow temperature productionfacilitiesFood storage for temporaryeventsStandby/emergency backupfor cold storesCalculating the cooling capacity required and choosing thecorrect modelDue to the many factors that must be considered when selecting a unit forlow temperature close control applications, we recommend that a full sitesurvey is carried out by an <strong>Andrews</strong> <strong>Sykes</strong> specialist. We can advise not onlythe best unit for the application but also the best method of installation.Selection and installation of your portable chillerThe units are portable and can be delivered and installed within a very shortperiod of time. The larger units require a 3 phase 415 volt electrical supplyand due to the physical size and weight of the units special considerationshould be made for the positioning of both the room units and the heatexchanger. The connection pipes between the room unit and the heator Call Us Free 0800 211 61139

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!