2.10 Cooling unit<br />

The arrangement of the cooling unit for<br />

the ZF 10 M, ZF 12 M, ZF 15 M, ZF 15<br />

MA, ZF 15 MIV, ZF 25 M <strong>and</strong> 25 MA (no<br />

cooling is required for ZF 3 M <strong>and</strong> 5 M)<br />

can be seen from Fig.15.<br />

The table below shows the maximum<br />

power output in continuous operation (lever<br />

position A <strong>and</strong> B) usable without cooling.<br />

When these values are exceeded,<br />

a cooling unit is required.<br />

The cooling unit should be connected to<br />

the fresh-water pressure line (external<br />

circuit) of the engine in accordance with<br />

Fig.16. The minimum volume of flow is<br />

10 ltr/min. Retrofitting of the cooling unit<br />

involves no problems (see item 6.15).<br />

2.11 Engine-gearbox compartment<br />

Care should be taken that the engine<br />

gearbox compartment is properly ventilated.<br />

32<br />

Manual <strong>and</strong> Spare Parts List ZF M line<br />

Fig. 15<br />

Max. engine power usable without cooling<br />

Lever position ZF 3 M ZF 10 M ZF 12 M ZF 15 MIV ZF 25 M<br />

ZF 5 M ZF 15 M ZF 25 MA<br />

ZF 15 MA<br />

A no cooling no cooling 40 kW 25 kW 40 kW<br />

54 hp 34 hp 54 hp<br />

B no cooling 25 kW 25 kW 20 kW always with<br />

34 hp 34 hp 34 hp cooling unit<br />

Fig. 16<br />

10 liters/min<br />

2.6 gal/min