2.3 Application developmentThis section explains about the application development.• Parameter settingsTo ensure normal operation of the system, you must set parameters to the appropriate valuesby using the engineering function.• Scan PeriodA safety application runs at intervals of a defined scan period.Determine a scan period to meet the requirements for the process safety time.• Input value for a fault and failsafe valueDefine the value input to the application logic when a fault is detected in an input module (inputvalue for a fault) and the value output from an output module when a fault is detected inthe CPU module or in the <strong>com</strong>munication between the CPU module and output module (failsafevalue). These can be individually defined on each channel.These values, that determine the safety state, should be cautiously defined depending on theapplication. In general, 0 for De-energize to trip system and 1 for Energize to trip system isused. If different values are used, the immediate repair after a failure occurs should be considered.• Activation of output shutoff switchThe Output Shutoff Switch in the output module is a <strong>com</strong>mon switch to all channels and normallyclosed (ON). The switch is activated to shut off all channels of the output module whena stuck-at-ON fault that the channel cannot output OFF (0) for a digital output module (24 VDC or 48 V DC) or an output current read back error for an analog output module is detectedby the diagnostic test, if the setting of the channel is the default value.The behavior of the output shutoff switch is definable per channel. Select the default value toall channels for a safety application, which activates the switch when the fault mentionedabove is detected in a channel.• Diagnostics of field wiringFor each channel of I/O modules, specify whether to perform diagnosis of field wiring.• Timeout settings for inter-SCS safety <strong>com</strong>munication and SCS link transmissionsafety <strong>com</strong>municationSet the proper timeout values for the inter-SCS safety <strong>com</strong>munication dedicated FB and SCSlink transmission safety <strong>com</strong>munication parameter.For calculation of the timeout values, refer to Engineering Guide (IM 32Q01C10-31E).• ProgrammingThe engineering function of the ProSafe-RS provides the programming languages conformingto the IEC 61131-3 standard. The following languages are used to program safety application.• FBD (Function Block Diagram)• LD (Ladder Diagram)• ST (Structured Text) 2-7Use proper FU/FB, LD elements, and ST statements of these languages. Some of them canbe used for safety applications, but the others cannot. Some of them can be used for safetyIM 32Q01S10-31E2nd Edition : Dec.28,2012-00

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!