13.07.2015 Views

Safety Manual - Tuv-fs.com

Safety Manual - Tuv-fs.com

Safety Manual - Tuv-fs.com

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

2-4Interference free I/O moduleEthernet Communication Module• Environmental requirementsRefer to ProSafe-RS Installation Guidance (TI 32S01J10-01E) for details of the permissibleenvironmental conditions for ProSafe-RS, and its connection with external devices.• Fault detection and reaction• Basic behaviorCPU modules and I/O modules are diagnosed by the hardware and software periodically. Errorsin <strong>com</strong>munication between CPU module and I/O modules and in inter-SCS safety <strong>com</strong>municationsare detected by various measures.When an error is detected, the failsafe value is used for the output value and a diagnostic informationmessage is issued. The diagnostic information message, which is sent to the SENGand HIS (when integrated with CENTUM) via the control bus, is useful for identifying the detailsand the cause of the error.In a dual-redundant configuration, the other module that is working normally takes over controlto continue the operation. The diagnostic information message that is issued at the sametime helps identify the failed module.The user can define the fail-safe behavior of the system when faults are detected in I/O modules.The following section describes the details.• Diagnosis and reactionThis section explains the fault detection and reaction of the system in the single configuration.In a dual-redundant configuration, the other module that is working normally takes over controlto continue the operation.• CPU ModuleThe major <strong>com</strong>ponents in the CPU module are duplexed, and their operation results arealways <strong>com</strong>pared between the two. This enables to detect a fault in a very short time.The detection of a fault causes a shutdown of the CPU module. Accordingly, the outputmodules detect a <strong>com</strong>munication halt of the CPU module and outputs the failsafe valuepredefined for each channel.• Input ModuleDiagnostic tests of input modules are performed by the firmware periodically. When oneof the following faults is detected, the status of input channel changes to “bad” and a predefinedvalue (input value of error occurrence) is transferred to the application logic. Thismeans, faults in input modules, as well as demands (changes in input values), can behandled by application logic.• Fault in the <strong>com</strong>mon part of an input module• Fault in an input channel• Failure in <strong>com</strong>munication between an input module and a CPU module• Output ModuleDiagnostic tests of output modules are performed by the firmware periodically. When oneof the following faults is detected, the Output Shutoff Switch is activated to force all theoutput channels to OFF (0).• Fault in the <strong>com</strong>mon part of an output module• A channel is stuck-at-ON, that is, the output cannot be turned to OFF (digital outputmodule (24 V DC, 48 V DC))IM 32Q01S10-31E2nd Edition : Dec.28,2012-00

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!