Agilent HPLC Column Selection Guide

Agilent HPLC Column Selection Guide Agilent HPLC Column Selection Guide

13.07.2015 Views

Columns for Special Applications1100 Series Conversion Kits for Fast LCThese kits make it easy to convert your Agilent 1100 system with a binary pump to alower-volume system for RRHT LC columns. Each kit contains all capillaries, a flow cell,starter columns, and detailed instructions for system conversion. Note: you will still be ableto use your converted 1100 for standard methods and columns.Kit Selection Description Part No.For Variable WavelengthDetectors (VWD)For Diode Array Detectors(DAD & DAD SL) and MultipleWavelength Detectors (MWD)For Diode Array Detectorand Mass SpecColumns: 4.6 x 50 mm, 1.8 µm (3)Flow Cell for VWD, 5 µl capillaries, µ-LC inline filterColumns: 4.6 x 50 mm, 1.8 µm (2)Flow Cell for DAD, 5 µl capillaries, µ-LC inline filterColumns: 2.1 x 50 mm, 1.8 µm (2)Flow Cell for DAD, 1.7 µl capillaries, ZDV union5188-53235188-53245188-5328Rapid Resolution HT: Up to 20X FasterColumn A: ZORBAX SB-C18883975-9024.6 x 150 mm, 5 µmColumn B: ZORBAX SB-C18827700-9022.1 x 50 mm, 1.8 µmColumn C: ZORBAX SB-C18827700-9022.1 x 50 mm, 1.8 µmMobile Phase: A: H 2 OB: ACNGradient: 0.0 min 50% BA: 11 min 100%BB: 1.2 min 100%BC: 0.4 min 100%BFlow Rate: A: 1.2 mL/minB: 1.0 mL/minC: 2.4 mL/minTemperature: A: 40°CB: 40°CC: 95°CDetector: UV 254 nmSample:Alkylphenones11. C 3 -AlkylphenoneA2435 67 8 92.3.C 4 -AlkylphenoneC 5 -Alkylphenone4. C 6 -Alkylphenone5. C 7 -Alkylphenone40 2 4 6 8 10Time (min)6.7.C 8 -AlkylphenoneC 9 -AlkylphenoneB128. C 10 -Alkylphenone35 69. C 12 -Alkylphenone7 8 90 0.2 0.4 0.6 0.8 1.0Time (min)41 2C35 67 8 90 0.2 0.4Time (min)LCRR00178 Order online at www.agilent.com/chem/store

Columns for Special ApplicationsRapid Resolution HT Provides Doublethe Efficiency of Rapid Resolution ColumnsColumn A:Column B:Mobile Phase:Flow Rate:Temperature:Detector:ZORBAX SB-C18835975-9024.6 x 50 mm, 3.5 µmZORBAX SB-C18827975-9024.6 x 50 mm, 1.8 µm25% Water, 75% MeOH1.5 mL/minAmbient254 nmThis figure shows that Rapid Resolution HTcolumns can provide double the efficiencyof a 3.5 µm column in the same column length.This high efficiency can be used for veryhigh-resolution, high throughput analyses.A012Plates (N)1. 34762. 45853. 56734. 61803Time (min)41B1. Uracil2. Phenol3. 4-CI-Nitrobenzene4. Toluene0.012Plates (N)1. 65602. 89583. 115084. 1226630.5Time (min)41.0LCRR002Increase Peak Capacity with RRHT ColumnsColumn A: Eclipse XDB-C8928700-9062.1 x 100 mm, 1.8 µmColumn B: Eclipse XDB-C18961753-9022.1 x 100 mm, 3.5 µmMobile Phase: A: H 2 OB: ACNPeak capacity: A: 461B: 343Flow Rate: 0.5 mL/minGradient: 0.0 min 50% B20.0 min 100% BTemperature: 40°CDetector: UV 254 nmSample:AlkylphenonesAmAU120100806040200BmAU100806040200110 2 4 6 8 10 12 14 16 18Time (min)11. Uracil2. C 3 -Alkylphenone3. C 4 -Alkylphenone4. C 5 -Alkylphenone5. C 6 -Alkylphenone0 2 4 6 8 10 12 14 16 18Time (min)116. C 7 -Alkylphenone7. C 8 -Alkylphenone8. C 9 -Alkylphenone9. C 10 -Alkylphenone10. C 12 -Alkylphenone11. C 14 -Alkylphenone11LCRR004Order online at www.agilent.com/chem/store79

<strong>Column</strong>s for Special Applications1100 Series Conversion Kits for Fast LCThese kits make it easy to convert your <strong>Agilent</strong> 1100 system with a binary pump to alower-volume system for RRHT LC columns. Each kit contains all capillaries, a flow cell,starter columns, and detailed instructions for system conversion. Note: you will still be ableto use your converted 1100 for standard methods and columns.Kit <strong>Selection</strong> Description Part No.For Variable WavelengthDetectors (VWD)For Diode Array Detectors(DAD & DAD SL) and MultipleWavelength Detectors (MWD)For Diode Array Detectorand Mass Spec<strong>Column</strong>s: 4.6 x 50 mm, 1.8 µm (3)Flow Cell for VWD, 5 µl capillaries, µ-LC inline filter<strong>Column</strong>s: 4.6 x 50 mm, 1.8 µm (2)Flow Cell for DAD, 5 µl capillaries, µ-LC inline filter<strong>Column</strong>s: 2.1 x 50 mm, 1.8 µm (2)Flow Cell for DAD, 1.7 µl capillaries, ZDV union5188-53235188-53245188-5328Rapid Resolution HT: Up to 20X Faster<strong>Column</strong> A: ZORBAX SB-C18883975-9024.6 x 150 mm, 5 µm<strong>Column</strong> B: ZORBAX SB-C18827700-9022.1 x 50 mm, 1.8 µm<strong>Column</strong> C: ZORBAX SB-C18827700-9022.1 x 50 mm, 1.8 µmMobile Phase: A: H 2 OB: ACNGradient: 0.0 min 50% BA: 11 min 100%BB: 1.2 min 100%BC: 0.4 min 100%BFlow Rate: A: 1.2 mL/minB: 1.0 mL/minC: 2.4 mL/minTemperature: A: 40°CB: 40°CC: 95°CDetector: UV 254 nmSample:Alkylphenones11. C 3 -AlkylphenoneA2435 67 8 92.3.C 4 -AlkylphenoneC 5 -Alkylphenone4. C 6 -Alkylphenone5. C 7 -Alkylphenone40 2 4 6 8 10Time (min)6.7.C 8 -AlkylphenoneC 9 -AlkylphenoneB128. C 10 -Alkylphenone35 69. C 12 -Alkylphenone7 8 90 0.2 0.4 0.6 0.8 1.0Time (min)41 2C35 67 8 90 0.2 0.4Time (min)LCRR00178 Order online at www.agilent.com/chem/store

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!