Agilent HPLC Column Selection Guide
Agilent HPLC Column Selection Guide Agilent HPLC Column Selection Guide
Columns for Analytical HPLCZORBAX 80Å StableBondDescription Size (mm) Particle Size (µm)SB-C18USP L1Capillary Glass-lined ColumnsCapillary 0.5 x 250 5 5064-8258Capillary 0.5 x 150 5 5064-8256Capillary 0.5 x 35 5 5064-8254Capillary RR 0.5 x 150 3.5 5064-8262Capillary RR 0.5 x 35 3.5 5064-8260Capillary 0.3 x 250 5 5064-8257Capillary 0.3 x 150 5 5064-8255Capillary 0.3 x 35 5 5064-8253Capillary RR 0.3 x 150 3.5 5064-826148 Order online at www.agilent.com/chem/store
Columns for Analytical HPLCZORBAX Rx• Rx-C18 is recommended for alternate selectivity at low pH relative to Eclipse XDB-C18and StableBond SB-C18; for higher temperature applications, StableBond is recommended.This column has a higher carbon load than SB-C18 columns (12% vs. 10%).• Rx-C18 offers high stability and good peak shape for low pH applications.• Rx-C18 is manufactured using dimethyloctadecylsilane, is non-endcapped and providesexcellent stability up to pH 8.• Rx-C8 is the same product as SB-C8.Column SpecificationsBonded PhasePoreSizeSurfaceAreaTemp.LimitspHRange*EndcappedCarbonLoadZORBAX Rx-C18 80Å 180 m 2 /g 60°C 2.0-8.0 No 12%ZORBAX Rx-C8 80Å 180 m 2 /g 80°C 1.0-8.0 No 5.5%Specifications represent typical values only.*At pH 6-9 highest column stability for all silica based columns is obtained by operating at temperatures < 40°C and usinglower buffer concentrations in the range of 0.01 - 0.02M.Analysis of Diazepam on Rx-C18Column: ZORBAX Rx-C18880967-3023.0 x 250 mm, 5 µmMobile Phase: 35% H 2 O: 65% MeOHFlow Rate: 0.5 mL/min121. Ethylparaben2. DiazepamAn Rx-C18 column is used for this USP analysis of diazepam and the internal standardethylparaben. The Solvent Saver 3.0 mm i.d. Rx-C18 column reduces solvent usage by60% over what would be used if the analysis were done on a 4.6 x 250 mm column.0.0 2.5 5.0 7.5Time (min)LCRX001Order online at www.agilent.com/chem/store49
- Page 1 and 2: Agilent HPLCColumn Selection GuideE
- Page 3 and 4: New columns deliver on the promise
- Page 5 and 6: HPLC Column Selection GuidelinesHPL
- Page 7 and 8: HPLC Column Selection GuidelinesQui
- Page 9 and 10: HPLC Column Selection GuidelinesSma
- Page 11 and 12: HPLC Column Selection GuidelinesSil
- Page 13 and 14: HPLC Column Selection GuidelinesQui
- Page 15 and 16: HPLC Column Selection GuidelinesMet
- Page 17 and 18: HPLC Column Selection GuidelinesOpt
- Page 20 and 21: HPLC Column Selection GuidelinesCar
- Page 22 and 23: Columns for Analytical HPLCPoroshel
- Page 24 and 25: Columns for Analytical HPLCEnvironm
- Page 26 and 27: Columns for Analytical HPLCZORBAX E
- Page 28 and 29: Columns for Analytical HPLCRapid An
- Page 30 and 31: Columns for Analytical HPLCZORBAX E
- Page 32 and 33: Columns for Analytical HPLCZORBAX E
- Page 34 and 35: Columns for Analytical HPLCOOOOOCH
- Page 36 and 37: Columns for Analytical HPLCColumn S
- Page 38 and 39: Columns for Analytical HPLCZORBAX E
- Page 40 and 41: Columns for Analytical HPLCZORBAX E
- Page 42 and 43: Columns for Analytical HPLCZORBAX 8
- Page 44 and 45: Columns for Analytical HPLCSB-CN Op
- Page 46 and 47: Columns for Analytical HPLCZORBAX 8
- Page 48 and 49: Columns for Analytical HPLCZORBAX 8
- Page 52 and 53: Columns for Analytical HPLCRx-C8 an
- Page 54 and 55: Columns for Analytical HPLCZORBAX 8
- Page 56 and 57: Columns for Analytical HPLCExtend-C
- Page 58 and 59: Columns for Analytical HPLCR 1O SiP
- Page 60 and 61: Columns for Analytical HPLCZORBAX B
- Page 62 and 63: Columns for Analytical HPLCZORBAX B
- Page 64 and 65: Columns for Analytical HPLCZORBAX N
- Page 66 and 67: Columns for Analytical HPLCNormal P
- Page 68 and 69: Columns for Analytical HPLCZORBAX H
- Page 70 and 71: Columns for Analytical HPLCZORBAX M
- Page 72 and 73: Columns for Analytical HPLCZORBAX M
- Page 74 and 75: Columns for Analytical HPLCCough-Co
- Page 76 and 77: Columns for Special ApplicationsZOR
- Page 78 and 79: Columns for Special ApplicationsSub
- Page 80 and 81: Columns for Special Applications110
- Page 82 and 83: Columns for Special ApplicationsRed
- Page 84 and 85: Columns for Special ApplicationsRap
- Page 86 and 87: Columns for Special ApplicationsRap
- Page 88 and 89: Columns for Special ApplicationsRun
- Page 90 and 91: Columns for Special ApplicationsZOR
- Page 92 and 93: Columns for Special ApplicationsZOR
- Page 94 and 95: Columns for Special ApplicationsZOR
- Page 96 and 97: Columns for Special ApplicationsZOR
- Page 98 and 99: Columns for Special ApplicationsSca
<strong>Column</strong>s for Analytical <strong>HPLC</strong>ZORBAX Rx• Rx-C18 is recommended for alternate selectivity at low pH relative to Eclipse XDB-C18and StableBond SB-C18; for higher temperature applications, StableBond is recommended.This column has a higher carbon load than SB-C18 columns (12% vs. 10%).• Rx-C18 offers high stability and good peak shape for low pH applications.• Rx-C18 is manufactured using dimethyloctadecylsilane, is non-endcapped and providesexcellent stability up to pH 8.• Rx-C8 is the same product as SB-C8.<strong>Column</strong> SpecificationsBonded PhasePoreSizeSurfaceAreaTemp.LimitspHRange*EndcappedCarbonLoadZORBAX Rx-C18 80Å 180 m 2 /g 60°C 2.0-8.0 No 12%ZORBAX Rx-C8 80Å 180 m 2 /g 80°C 1.0-8.0 No 5.5%Specifications represent typical values only.*At pH 6-9 highest column stability for all silica based columns is obtained by operating at temperatures < 40°C and usinglower buffer concentrations in the range of 0.01 - 0.02M.Analysis of Diazepam on Rx-C18<strong>Column</strong>: ZORBAX Rx-C18880967-3023.0 x 250 mm, 5 µmMobile Phase: 35% H 2 O: 65% MeOHFlow Rate: 0.5 mL/min121. Ethylparaben2. DiazepamAn Rx-C18 column is used for this USP analysis of diazepam and the internal standardethylparaben. The Solvent Saver 3.0 mm i.d. Rx-C18 column reduces solvent usage by60% over what would be used if the analysis were done on a 4.6 x 250 mm column.0.0 2.5 5.0 7.5Time (min)LCRX001Order online at www.agilent.com/chem/store49