Agilent HPLC Column Selection Guide
Agilent HPLC Column Selection Guide Agilent HPLC Column Selection Guide
Columns for Analytical HPLCSB-CN Optimizes Retention and ResolutionColumn A: ZORBAX SB-C18866953-9024.6 x 75 mm, 3.5 µmColumn B: ZORBAX SB-CN866953-9054.6 x 75 mm, 3.5 µmMobile Phase: 30% ACN70% 25mM NaH 2 PO 4 , pH 2.5Flow Rate: 1.0 mL/minTemperature: 35°CA12341. Estriol2. Daidzen3. Quercetin4. Genistein5. Diethylstilbestrol5B21 3450 5 10 15 20 25Time (min)0 2 4 6 8 10 12Time (min)The SB-CN column is used here to reduce analysis time by 50%. The retention of the most hydrophobic analyte is cut in half. At the same time retention of the more polar,early eluting peaks increases slightly.LCSB003More RRHT Bonded Phase ChoicesAllow for Rapid Method Development OptimizationColumn A: ZORBAX SB-C18827975-9024.6 x 50 mm, 1.8 µmColumn B: SB-C8827975-9064.6 x 50 mm, 1.8 µmColumn C: ZORBAX SB-Phenyl827975-9124.6 x 50 mm, 1.8 µmColumn D: ZORBAX SB-CN827975-9054.6 x 50 mm, 1.8 µmMobile Phase: Acetonitrile (40%):Buffer 60% pH=2.425mM NaH 2 PO 4Flow Rate: 1.85 mL/minDetector: DAD, 254 nmLC: Agilent 1200 RR LCSample:As listed, 1 µL injection5 Different Bonded Phase Choices in StableBondfamily enhance method optimization.Note: SB-Aq not shown.mAU4504003503002502001501005000ABCD11. Tolmetin2. Naproxen3. Diflunisal4. Ibuprofen5. DiclofenacChange in Elution Order Peaks 3, 4 & 521351 2 3541325425341 2 3 4 54minMoreRRHT42 Order online at www.agilent.com/chem/store
Columns for Analytical HPLCFive Different Bonded Phases Provide Selectivity OptionsColumn A:Column B:ZORBAX SB-C18883975-9024.6 x 150 mm, 5 µmZORBAX SB-C8883975-9064.6 x 150 mm, 5 µmA13254Column C:Column D:Column E:Mobile Phase:ZORBAX SB-C3883975-9094.6 x 150 mm, 5 µmZORBAX SB-Phenyl883975-9124.6 x 150 mm, 5 µmZORBAX SB-CN883975-9054.6 x 150 mm, 5 µm0-100% B in 18.8 minA: 50 mM NaH 2 PO 4 ,pH 2.5 in 95% H 2 O / 5% ACNB: 50 mM NaH 2 PO 4 ,pH 2.5 in 47% H 2 O / 53% ACNBC113235454Flow Rate: 1.0 mL/minTemperature: 26°CDetector: 254 nmSample:1. Procaine2. Lidocaine3. d-Cinchonine4. Butacaine5. TetracaineD231452SB-C3 is just one of the five different StableBond selectivity choices. In thisexample, optimum resolution is obtained with SB-C3. All are based on the samehigh purity Rx-SIL. Selectivity changes are therefore dependent only on the bondedphases, making method development more reliable.E132450 5 1015Time (min)LCSB004Order online at www.agilent.com/chem/store43
- Page 1 and 2: Agilent HPLCColumn Selection GuideE
- Page 3 and 4: New columns deliver on the promise
- Page 5 and 6: HPLC Column Selection GuidelinesHPL
- Page 7 and 8: HPLC Column Selection GuidelinesQui
- Page 9 and 10: HPLC Column Selection GuidelinesSma
- Page 11 and 12: HPLC Column Selection GuidelinesSil
- Page 13 and 14: HPLC Column Selection GuidelinesQui
- Page 15 and 16: HPLC Column Selection GuidelinesMet
- Page 17 and 18: HPLC Column Selection GuidelinesOpt
- Page 20 and 21: HPLC Column Selection GuidelinesCar
- Page 22 and 23: Columns for Analytical HPLCPoroshel
- Page 24 and 25: Columns for Analytical HPLCEnvironm
- Page 26 and 27: Columns for Analytical HPLCZORBAX E
- Page 28 and 29: Columns for Analytical HPLCRapid An
- Page 30 and 31: Columns for Analytical HPLCZORBAX E
- Page 32 and 33: Columns for Analytical HPLCZORBAX E
- Page 34 and 35: Columns for Analytical HPLCOOOOOCH
- Page 36 and 37: Columns for Analytical HPLCColumn S
- Page 38 and 39: Columns for Analytical HPLCZORBAX E
- Page 40 and 41: Columns for Analytical HPLCZORBAX E
- Page 42 and 43: Columns for Analytical HPLCZORBAX 8
- Page 46 and 47: Columns for Analytical HPLCZORBAX 8
- Page 48 and 49: Columns for Analytical HPLCZORBAX 8
- Page 50 and 51: Columns for Analytical HPLCZORBAX 8
- Page 52 and 53: Columns for Analytical HPLCRx-C8 an
- Page 54 and 55: Columns for Analytical HPLCZORBAX 8
- Page 56 and 57: Columns for Analytical HPLCExtend-C
- Page 58 and 59: Columns for Analytical HPLCR 1O SiP
- Page 60 and 61: Columns for Analytical HPLCZORBAX B
- Page 62 and 63: Columns for Analytical HPLCZORBAX B
- Page 64 and 65: Columns for Analytical HPLCZORBAX N
- Page 66 and 67: Columns for Analytical HPLCNormal P
- Page 68 and 69: Columns for Analytical HPLCZORBAX H
- Page 70 and 71: Columns for Analytical HPLCZORBAX M
- Page 72 and 73: Columns for Analytical HPLCZORBAX M
- Page 74 and 75: Columns for Analytical HPLCCough-Co
- Page 76 and 77: Columns for Special ApplicationsZOR
- Page 78 and 79: Columns for Special ApplicationsSub
- Page 80 and 81: Columns for Special Applications110
- Page 82 and 83: Columns for Special ApplicationsRed
- Page 84 and 85: Columns for Special ApplicationsRap
- Page 86 and 87: Columns for Special ApplicationsRap
- Page 88 and 89: Columns for Special ApplicationsRun
- Page 90 and 91: Columns for Special ApplicationsZOR
- Page 92 and 93: Columns for Special ApplicationsZOR
<strong>Column</strong>s for Analytical <strong>HPLC</strong>Five Different Bonded Phases Provide Selectivity Options<strong>Column</strong> A:<strong>Column</strong> B:ZORBAX SB-C18883975-9024.6 x 150 mm, 5 µmZORBAX SB-C8883975-9064.6 x 150 mm, 5 µmA13254<strong>Column</strong> C:<strong>Column</strong> D:<strong>Column</strong> E:Mobile Phase:ZORBAX SB-C3883975-9094.6 x 150 mm, 5 µmZORBAX SB-Phenyl883975-9124.6 x 150 mm, 5 µmZORBAX SB-CN883975-9054.6 x 150 mm, 5 µm0-100% B in 18.8 minA: 50 mM NaH 2 PO 4 ,pH 2.5 in 95% H 2 O / 5% ACNB: 50 mM NaH 2 PO 4 ,pH 2.5 in 47% H 2 O / 53% ACNBC113235454Flow Rate: 1.0 mL/minTemperature: 26°CDetector: 254 nmSample:1. Procaine2. Lidocaine3. d-Cinchonine4. Butacaine5. TetracaineD231452SB-C3 is just one of the five different StableBond selectivity choices. In thisexample, optimum resolution is obtained with SB-C3. All are based on the samehigh purity Rx-SIL. Selectivity changes are therefore dependent only on the bondedphases, making method development more reliable.E132450 5 1015Time (min)LCSB004Order online at www.agilent.com/chem/store43