13.07.2015 Views

Agilent HPLC Column Selection Guide

Agilent HPLC Column Selection Guide

Agilent HPLC Column Selection Guide

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>HPLC</strong> <strong>Column</strong> <strong>Selection</strong> <strong>Guide</strong>linesOptimize solvents and bonded phases at low pHThe initial method development steps may lead very quickly to a satisfactory separation. But ifmore optimization is needed, acetonitrile can be replaced by methanol or tetrahydrofuran andthe separation re-optimized. This step may lead to a satisfactory solution, but if still moreselectivity optimization is needed, the column bonded phase can be changed.At low pH there are many bonded phase choices available for optimization. These include theEclipse Plus phases as well as the Eclipse XDB family with C18, C8, Phenyl and CN. Alternatechoices include six different StableBond bonded phases: SB-C18, SB-C8, SB-Phenyl, SB-CN,SB-C3, and SB-Aq.It may be necessary at low pH to improve the retention of acidic compounds. For thesesituations, lower the pH even further, down to pH 1-2, and use StableBond columns. Thesecolumns provide the greatest stability at very low pH and provide many selectivity optionsfor achieving the highest resolution separations.Choose <strong>Agilent</strong> ZORBAX Eclipse Plusfor method development at mid pH (4-9)There are some samples that may not be resolved at low pH or may have better solubilityand stability at mid pH. While still using the Eclipse Plus C18 column, the mid pH range canbe used for method development. The Eclipse Plus column is stable up to pH 9 so it is equallyreliable at mid pH. These double endcapped columns have two key advantages – good peakshape at low and mid pH, as well as sufficient bonded phase density to protect the columnfrom silica degradation from pH 6-9.At mid pH, basic compounds (e.g., amines) may still have a positive charge and the silanolson the silica surface may have a negative charge. Therefore covering as many silanols aspossible leads to the best peak shape at mid pH. This makes the Eclipse Plus C18 the beststarting choice for a column at mid pH. Phosphate buffer is usually the first choice for mobilephase modifier at pH 7 because its buffer range is pH 6.1-8.1. A second choice for mid pHis acetate buffer since it buffers from pH 3.8-5.8 and its volatility makes it a good choice forLC/MS compatibility.Order online at www.agilent.com/chem/store15

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!