13.07.2015 Views

Minicontactorrelay,4NO/0NC,DCoperated Partno ... - BRIO ELECTRIC

Minicontactorrelay,4NO/0NC,DCoperated Partno ... - BRIO ELECTRIC

Minicontactorrelay,4NO/0NC,DCoperated Partno ... - BRIO ELECTRIC

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Minicontactorrelay</strong>,<strong>4NO</strong>/<strong>0NC</strong>,<strong>DCoperated</strong><strong>Partno</strong>.DILER-40-G(220VDC)Articleno. 010303ProgramProduct range DILER Mini-contactorsApplication Contactor relaysConnection technique Screw terminalsRated operational currentAC-15220 V230 V240 V380 V400 V415 VI e A 6I e A 3Conv. thermal current I th A 10ContactsN/O = Normally open 4 N/OContact sequenceFor use with …DILEActuating voltage 220 V DCVoltage AC/DC DC operationCode number and version of combinationDistinctive number 40 EAuxiliary contact moduleInterlocked opposing contacts 40E Conforms to EN 50011 - terminalmarkings of the coil according to EN50005Interlocked opposing contacts 02DILE 42E EN 50011 - Use preferably thiscombinationInterlocked opposing contacts 04DILE 44E EN 50011 - Use preferably thiscombinationInterlocked opposing contacts 11DILE 51E EN 50011 - Use preferably thiscombination1 early-make contact, 1 late-break11DDILE 51 EN 50005contactInterlocked opposing contacts 13DILE 53E EN 50011 - Use preferably thiscombinationInterlocked opposing contacts 20DILE 60E EN 50011 - Use preferably thiscombinationInterlocked opposing contacts 22DILE 62E EN 50011 - Use preferably thiscombination1 early-make contact, 1 late-break22DDILE 62 EN 50005contactInterlocked opposing contacts 31DILE 71E EN 50011 - Use preferably thiscombinationInterlocked opposing contacts 40DILE 80E EN 50011 - Use preferably thiscombinationInstructionsContact numbers to EN 50011Coil terminal markings to EN 50005Integrated diode-resistor combinationCoil rating 2.6 WApprobationenProduct StandardsIEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE markingUL File No.E29184UL CCNNKCRCSA File No. 012528CSA Class No. 3211-03NA CertificationUL listed, CSA certifiedSpecially designed for NANoGeneralStandards IEC/EN 60947, VDE 0660, UL, CSAClimatic proofing Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to IEC60068-2-3011/13/2011 HPL-ED2011 V2.0 EN (UX111) 1 / 4


Protection against direct contact when actuated from front (EN 90274) Finger and back-of-hand proofTerminal capacities mm 2Pozidriv screwdriver Size 2Max. tightening torque Nm 1.2ContactsOvervoltage category/pollution degree III/3Rated insulation voltage U i VAC690Rated operational current I e AAC-15220/240 V I e A 6380/415 V I e A 3Conv. thermal current I th A 10MagnetsystemsPower consumption50 Hz Pick-up VA 25TechnicaldataaccordingtoETIM4.0Connection type main circuit Screw connectionRated control voltage Us at DC V 220Rated control voltage Us at AC 60HZ V 0Rated control voltage Us at AC 50HZ V 0Number of auxiliary contacts as changeover contacts 0Rated operation current Ie , 400 V A 3Number of auxiliary contacts as N/Cs 0Number of auxiliary contacts as N/Os 4Voltage type for actuation DCNumber of auxiliary contacts as N/Os, leading 0Number of auxiliary contacts as N/Cs, delayed switching 0Characteristics11/13/2011 HPL-ED2011 V2.0 EN (UX111) 2 / 4


1: Suppressor2: Auxiliary contact moduleCAD-DataProduct standards CAD data:http://eaton-moeller.partcommunity.comDimensions11/13/2011 HPL-ED2011 V2.0 EN (UX111) 3 / 4


DILER-…DILER-…-GDILER-… + …DILEDILER-…-G + …DILEAdditionalproductinformation(links)IL03407009Z (IL03407009Z) Mini contactor relayInstallation InstructionsDocumentationftp://ftp.moeller.net/DOCUMENTATION/AWA_INSTRUCTIONS/IL03407009Z2010_10.pdfhttp://www.moeller.net/en/support/instructions_awa.jsphttp://www.moeller.net/en/support/index.jsp11/13/2011 Eaton Industries GmbHhttp://www.moeller.net/en© 07/2011 by Eaton Industries GmbHHPL-ED2011 V2.0 EN4 / 4

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!