13.07.2015 Views

COLD PANEL CURVING - Trespa.info

COLD PANEL CURVING - Trespa.info

COLD PANEL CURVING - Trespa.info

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>COLD</strong> <strong>PANEL</strong> <strong>CURVING</strong>This document is intended to provide general recommendations only. <strong>Trespa</strong> provides these guidelines and all testing, codeand design data for <strong>info</strong>rmational purposes only and strongly advises that the customer, project owner and architect seekindependent advice from a certified construction professional and/or engineer regarding application and installation as wellas compliance with design requirements, applicable codes, laws and regulations, and test standards. Please check your localcodes and applicable design requirements for proper use.“Cold panel curving” to form radius panels is not covered by the certificates or test reports available for <strong>Trespa</strong>® Meteon® panels.If <strong>Trespa</strong>® Meteon® panels are fixed mechanically to create a convex curved panel (radius) application, the fixings are stressedin a different way than a “flat” panel. This method of installation is beyond the scope of any certificate or test report.<strong>Trespa</strong>® Meteon® panels with a thickness of 6 mm (≈ 1/4 in) and 8 mm (≈ 5/16 in) may be mechanically fixed to a convexcurve on a suitable sub-frame. Depending on the thickness of the panel, a minimum panel radius and length to widthrelation is required (see Table).Panel thickness Minimum panel radius Minimum length Length to width relationmm in m in mm in6 ≈ 1/4 2 ≈ 79 1200 ≈ 47 1:28 ≈ 5/16 4 ≈ 157 1800 ≈ 71 1:2In order to ensure proper installation and application of curved structures, special requirements must be placed on thesub-frame and the fixing.Sub-frameAs much as possible the sub-frame structure has to support the panel over its full length.In order to achieve a smooth curved shape, it might be necessary to reduce the distances of the sub-frame construction.Quality and treatment of the sub-frame must be in accordance with applicable building standards, regulations, certificatesand should be calculated with great care by an architect or other construction professional.FixingInstallation of <strong>Trespa</strong>® Meteon® panels on a curved sub-frame must be done using visible mechanical fixings.The distance between fixings (e.g. rivets or screws) of the fixing system chosen should be reduced by as much as 25%.Proper engineering design should be conducted to determine this revised fixing spacing. The edge clearance of the fixingsnear the two straight edges at the end of the panel must be 20 mm (≈ 3/4 in).1Please check www.trespa.<strong>info</strong> for the latest version of this document


DisclaimerThis is a print generated by you from www.trespa.<strong>info</strong> (“Website”). By accessing the Website and printing this document you have accepted theTerms of Use of the Website. Please refer to the Website for all conditions that apply to this document. Not all the systems shown in this documentmay be suitable for all applications and jurisdictions. We provide you with testing, code and design data for <strong>info</strong>rmational purposes only andstrongly recommend that you or any other user of this document obtains independent advice regarding compliance with design requirements,applicable codes, laws and regulations, and test standards. Please check your local codes and design requirements for proper use. <strong>Trespa</strong> will notaccept any liability in relation to your use of this document.All intellectual property rights, including copyrights and other rights regarding the content of the Website and this print generated from the Website(including logos, trademarks, service marks, software, databases, audio, video, text and photographs) are owned by <strong>Trespa</strong> and/or its licensors.<strong>Trespa</strong>®, Meteon®, Athlon®, TopLab®, TopLab PLUS ®, TopLab ECO-FIBRE ®, Virtuon®, Volkern®, <strong>Trespa</strong> Essentials® and Mystic Metallics® are registeredtrademarks of <strong>Trespa</strong>.All oral and written statements, offers, quotations, sales, supplies, deliveries and/or agreements and all related activities of <strong>Trespa</strong> are governed by the<strong>Trespa</strong> General Terms and Conditions of Sale (Algemene verkoopvoorwaarden <strong>Trespa</strong> International B.V.) filed with the Chamber of Commerce andIndustry for Noord- en Midden- Limburg in Venlo (NL) on 11 April 2007 under number 24270677,which can be found on and downloaded fromthe <strong>Trespa</strong> website, www.trespa.com.All oral and written statements, offers, quotations, sales, supplies, deliveries and/or agreements and all related work of <strong>Trespa</strong> North America, Ltd. arecode V3059 version 2.0 date 06-15-2011governed by the <strong>Trespa</strong> General Terms and Conditions of Sale, which can be found on and downloaded from the <strong>Trespa</strong> North America Ltd. website,www.trespa.com/na. A copy of these general conditions of sale will be provided free of charge on request.2Please check www.trespa.<strong>info</strong> for the latest version of this document

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!