Product Data SheetTracer <strong>UC600</strong> Programmable ControllerOrdering number: BM<strong>UC600</strong>AAA0100011The Tracer <strong>UC600</strong> controller is a multi-purpose, programmable, wireless-compatible device. This field-installeddevice is designed to control the following types of equipment:• Air-handling units (AHUs)• Central heating and cooling plants• Cooling towers• Generic input/output (I/O) controlFeatures and BenefitsFeatureBACnet MS/TPConfigurable and fully programmableTotal of 19 built-in I/O hardware terminationsExpandable up to 120 hardware terminationsData logging—25,000 samplesRemovable connectors, DIN rail mounting,multiple service tool connectionsBenefitAn open standard building automation communications protocol which enablesconnections to other BAS systems and controllers• Factory programs available through quick configuration for lowest setup time• Programmable for flexibility to meet unique sequence or hardware needsMeets most applied product needs with built-in I/O or with additional customprogramming on the controllerFlexibility to meet additional equipment needsEasier investigation of equipment, zone, or building problemsEase of installation and serviceMarch 2011BAS-PRC063-EN


Input and Output SpecificationsInput/Output type Quantity Types Range NotesUniversal InputThermistor10kΩ – Type II, 10kΩ –Type III,2252Ω – Type II, 20kΩ – TypeIV, 100 kΩUniversal Input/Analog OutputInputs8Resistive (setpoint)RTDCurrentVoltageBinaryPulse Accumulator100Ω – 1MΩBalco (Ni-Fe), 1kΩ; 375 (Pt),1kΩ0–20 mA (linear)0–20 Vdc (linear)Dry contactMinimum 20 ms, opened orclosedConfigure using any combination of analog or binary inputs/analogoutputs6ThermistorResistive (setpoint)RTDCurrentVoltageBinaryPulse accumulator10kΩ – Type II, 10kΩ –Type III,2252Ω – Type II, 20kΩ – TypeIV, 100 kΩ100Ω –1MΩBalco (Ni-Fe), 1kΩ; 375 (Pt),1kΩ0–20 mA (linear)0–20 Vdc (linear)Dry contactMinimum 20 ms, opened orclosedThe <strong>UC600</strong> is limited to 10 combined 0–20mA inputs and/or outputs.CurrentVoltage0–20 mA @16 V0–10 Vdc @20 mAOutputs12.5ms to 1 second (12.5msPulseresolution), 1 second to 60seconds (0.5 second resolution)Binary Output 4 Relay (form A) wet 24 VAC, 0.5A maximum Ranges are given per contact.Pressure Input 1 3-wire 0–5 in H2OPoint total 19Pressure input supplied with 5 Vdc.Designed for Kavlico pressuretransducers.BAS-PRC063-EN 04 Mar 2011 3


Trane optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, theleader in creating and sustaining safe, comfortable and energy efficient environments, Trane offers a broadportfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For moreinformation, visit www.Trane.com.Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice.© 2011 Trane All rights reservedBAS-PRC063-EN 04 Mar 2011New

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!