13.07.2015 Views

Measuring Gas Velocity with the D-FL 100 Differential Pressure Bar

Measuring Gas Velocity with the D-FL 100 Differential Pressure Bar

Measuring Gas Velocity with the D-FL 100 Differential Pressure Bar

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

D−<strong>FL</strong> <strong>100</strong> Seite 319.3. Selecting <strong>the</strong> differential pressure bar materialThe standard material of <strong>the</strong> differential pressure bar is stainless steel. Special applications <strong>with</strong> criticalgases may require a differential pressure bar made of a different material. The following table gives arough overview of application ranges of different materials. O<strong>the</strong>r materials can be provided only uponrequest.MaterialCrNiMoTi 17 12 2(standard material)Area of application1.4571 Moderately corrosive environmentNiMo16Cr15WHastelloyC-2762.4819Durable, <strong>with</strong>stands various chemicalsChemical and petrochemical industriesCurrent plants and waste incinerators running onfossil fuels, as well as smoke gas desulphurizationplantsProduction of organic acidsNiCr15Fe Inconel 6022.4816Can be used up to 850°C (from 600°C)KilnsCatalytic generators in petrochemical processes9.4. Selecting <strong>the</strong> Type of Installation<strong>Differential</strong> pressure bars are available in various installation designs. They can be delivered <strong>with</strong> or<strong>with</strong>out counter bearings. Use of a counter bearing is recommended for stacks <strong>with</strong> large innerdiameters and also if unusually large forces in <strong>the</strong> gas could affect <strong>the</strong> differential pressure bar andcause resonance. The counter bearing is <strong>the</strong>refore a standard option for <strong>the</strong> differential pressure bar.The differential pressure transducer can also be connected directly to <strong>the</strong> differential pressure bar <strong>with</strong> aswitching valve and an adapter. If lack of space or o<strong>the</strong>r factors make this configuration impossible, adifferential pressure bar <strong>with</strong> a flange for connecting to a pressure line is available. It, in turn, willconnect <strong>the</strong> transducer/switching valve to <strong>the</strong> differential pressure bar (standard).GmbH

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!