D−<strong>FL</strong> <strong>100</strong> Seite 258. Specifications of <strong>the</strong> D-<strong>FL</strong> <strong>100</strong><strong>Measuring</strong> principle: Continuous in situ measurement by <strong>the</strong> differential pressure method.Lengths of <strong>the</strong> measuring paths:<strong>Differential</strong> pressure bar I: ...................................... 400 - 2000 mm (15 ¾ in. – 78 ¾ in.)<strong>Differential</strong> pressure bar II: ..................................... 2000 - 4000mm (78 ¾ in. – 157 ½ in.)<strong>Differential</strong> pressure bar lll: ..................................... 4000-8000mm (157 ½ in.) – 315 in.)<strong>Measuring</strong> range: ................................................... 0 - 2.000.000 Nm³/h,Minimum velocity: ................................................... 3 m/sExhaust temperature (standard material):............... min. greater than <strong>the</strong> dew point................................................................................. max. 400°C<strong>Differential</strong> pressure bar material: .......................... 1.4571 (standard),2.4819, 2.4816 according to customer requestMargin of error: ....................................................... +/-2%Electrical specifications of <strong>the</strong> D-<strong>FL</strong> <strong>100</strong>-10 DisplayVoltage: .................................................................. 115/230 V (±10%)Frequency: .............................................................. 50/60 Hz(O<strong>the</strong>r voltages and frequencies are available upon request.)Limiting valueTwo independently adjustable limiting values: L.V. 1, L.V. 21 x Status "Measure"All relay contacts potential-free,maximal load at cosϕ = 1: ...................................... 230V / 0.5AMaximum admissible ambient temperature range: -20° +50°CIntegration period of <strong>the</strong> measured value: .............. 1 - 180 sec (freely selectable)Output signal: ......................................................... analog 4 - 20 mAMaximum load: ....................................................... 500 OhmLive zero: ................................................................ 4 mAProtection/weight:rack mount model (IP20): ................................... 2,0 kghousing model (IP65): ....................................... 2,2 kgGmbH

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!