13.07.2015 Views

Measuring Gas Velocity with the D-FL 100 Differential Pressure Bar

Measuring Gas Velocity with the D-FL 100 Differential Pressure Bar

Measuring Gas Velocity with the D-FL 100 Differential Pressure Bar

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

D−<strong>FL</strong> <strong>100</strong> Seite 235.3. Error Messages on <strong>the</strong> D-<strong>FL</strong> <strong>100</strong>-10 DisplayThe D-<strong>FL</strong> <strong>100</strong>-10 Display puts out <strong>the</strong> following error messages on <strong>the</strong> display:Displayed error Cause of error SolutionE-01 The absolute pressure transmitterputs out a signal less than 3.8 mA.E-02 The temperature transmitter puts outa signal less than 3.8 mA.E-04 The differential pressure transmitterputs out a signal less than 3.8 mA.E-08 The current entering at <strong>the</strong> input of<strong>the</strong> differential pressure (absolutepressure or temperature) transmittermeasures more than 20 mA.Check connections and connectingwires. Calibrate transmitter ifnecessary.Check connections and connectingwires. Calibrate transmitter ifnecessary.Check connections and connectingwires. Calibrate transmitter ifnecessary.Check transmitter and calibrateanew if necessary.E-16 Defective RAM Restart unit and replace RAM-IC ifnecessary (DURAG service).E-32 Spill: <strong>the</strong> gas velocity is too high. Increase gas velocity measuringrange (see Section 5.2: Start-up,turn turning knob at setting 1, valueat L.V.1)E-64 EEPROM transmission error Restart unit and replace EEPROM ifnecessary (DURAG service).FEHLThe turning knob is switched to anillegal position ( > 3)Check <strong>the</strong> position of <strong>the</strong> turningknobThe displayed error number is <strong>the</strong> sum of all actual errors, e.g. E-05 means: E-01 and E-04.During <strong>the</strong>se error messages, a signal of 2 mA of current is read at <strong>the</strong> output of <strong>the</strong>D-<strong>FL</strong> <strong>100</strong>-10 Display.6. Recording of Measured DataThe D-<strong>FL</strong> <strong>100</strong>-10 Display puts out <strong>the</strong> present measured data as an analog electrical signal. Accordingto industry standards, <strong>the</strong>re should be a continuous recording of measured values. The following stripchart recorders are recommended: recorders of 0-20 mA <strong>with</strong> recording width of at least <strong>100</strong> mm. Thelive zero point of <strong>the</strong> display is at 20% (4 mA) of <strong>the</strong> recording scale.The measurements and status signals may, however, also be evaluated by an emission computerdownstream.GmbH

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!