TMS320C5x DSP STARTER KIT USER'S GUIDE
TMS320C5x DSP STARTER KIT USER'S GUIDE TMS320C5x DSP STARTER KIT USER'S GUIDE
Using Dialog BoxesYou can omit entries for optional parameters by pressing , but the debuggerwon’t allow you to skip required parameters. When you have entered allappropriate parameter values, Fill Program Memory finished appears at thebottom of the dialog box.In the case of the Modify menu when you select Data from its submenu, anempty dialog box appears on the screen:StartaddModify Data Memory of 320c50Pressfor the debugger to display the first parameter:Modify Data Memory of 320c50Startadd 1000Address: 1000 > efffnew:Enter the address you want to modify and pressin the dialog box.. The next parameter appearsStartadd 1000Modify Data Memory of 320c50Address: 1003 > ffffAddress: 0002 > 0003Address: 1001 > 0002Address: 1000 > 0001new q6-14
Using Dialog BoxesClosing a dialog boxWhen you’ve entered a value for the final parameter, there are three ways toexit from the dialog box: PressESC Press Press Q andPerforming the last of these options at the prompt causes the debugger toclose the dialog box and execute the command with the parameter values yousupplied.Using the DSK Debugger6-15
- Page 48 and 49: Assembling Your Program4.5 Assembli
- Page 50 and 51: 4-12
- Page 52 and 53: Using the DSK Assembler Directives5
- Page 54 and 55: Directives That Define Sections5.2
- Page 56 and 57: Directives That Reference Other Fil
- Page 58 and 59: Directives That Initialize Memory5.
- Page 60 and 61: Miscellaneous Directives5.6 Miscell
- Page 62 and 63: .byte/.stringDirectives ReferenceSy
- Page 64 and 65: .copy/.includeDirectives ReferenceL
- Page 66 and 67: .endDirectives ReferenceSyntax.endD
- Page 68 and 69: .float/.bfloat/.double/.efloat/.tfl
- Page 70 and 71: .if/.else/.endifDirectives Referenc
- Page 72 and 73: .liston/.listoffDirectives Referenc
- Page 74 and 75: .lqxx/.qxxDirectives ReferenceSynta
- Page 76 and 77: .mmregsDirectives ReferenceTable 5-
- Page 78 and 79: .setDirectives ReferenceSyntax symb
- Page 80 and 81: .spaceDirectives ReferenceListing f
- Page 82 and 83: .text / .psDirectives ReferenceExam
- Page 84 and 85: 5-34
- Page 86 and 87: Invoking the Debugger6.1 Invoking t
- Page 88 and 89: Invoking the DebuggerSetting the co
- Page 90 and 91: Using Pulldown Menus in the Debugge
- Page 92 and 93: Using Pulldown Menus in the Debugge
- Page 94 and 95: Using Pulldown Menus in the Debugge
- Page 96 and 97: Using Pulldown Menus in the Debugge
- Page 100 and 101: Using Software Breakpoints6.4 Using
- Page 102 and 103: Quick-Reference Guide6.5 Quick-Refe
- Page 104 and 105: Quick-Reference GuideTable 6-14.Deb
- Page 106 and 107: Circuit Board DimensionsFigure A-1.
- Page 108 and 109: Schematic DiagramP1594837261CONNECT
- Page 110 and 111: Schematic DiagramEODR\OUT-AUXIN-TCL
- Page 112 and 113: GlossaryCWindows that show code, te
- Page 114 and 115: GlossaryIIC:Integrated circuit. A t
- Page 116 and 117: Glossarysingle step: A form of prog
- Page 118 and 119: Indexconditional assembly, directiv
- Page 120 and 121: IndexinitializingCPU registers 6-10
- Page 122 and 123: IndexTtag, definition B-6temporary
Using Dialog BoxesYou can omit entries for optional parameters by pressing , but the debuggerwon’t allow you to skip required parameters. When you have entered allappropriate parameter values, Fill Program Memory finished appears at thebottom of the dialog box.In the case of the Modify menu when you select Data from its submenu, anempty dialog box appears on the screen:StartaddModify Data Memory of 320c50Pressfor the debugger to display the first parameter:Modify Data Memory of 320c50Startadd 1000Address: 1000 > efffnew:Enter the address you want to modify and pressin the dialog box.. The next parameter appearsStartadd 1000Modify Data Memory of 320c50Address: 1003 > ffffAddress: 0002 > 0003Address: 1001 > 0002Address: 1000 > 0001new q6-14