13.07.2015 Views

Smoke ventilation according to EN 12101-2 - D+H Mechatronic

Smoke ventilation according to EN 12101-2 - D+H Mechatronic

Smoke ventilation according to EN 12101-2 - D+H Mechatronic

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Fire detection elementsElements that respond with a change in state when a fire parameter occurs or changes.Width-height ratioRatio of width <strong>to</strong> height in bot<strong>to</strong>m hung, <strong>to</strong>p hung, side-hung and dormer windows.CE markingBy affixing the CE marking, the manufacturer confirms that the product conforms <strong>to</strong> the applicable EC directives.For further information, go <strong>to</strong>: http://www.vdi-nachrichten.com/ce-richtlinien/basics/index.asp.Coefficient of discharge (Cv) (with side wind influence)Ratio of actual flow rate, measured under specified conditions, <strong>to</strong> the theoretical flow rate through the naturalsmoke and heat exhaust ventila<strong>to</strong>r. The coefficient of discharge takes in<strong>to</strong> account any obstructions in the naturalsmoke and heat exhaust ventila<strong>to</strong>r such as controls, louvres, vanes and the influence of side winds.Coefficient of discharge (Cv0) (without side wind influence)Ratio of actual flow rate, measured under specified conditions, <strong>to</strong> the theoretical flow rate through the naturalsmoke and heat exhaust ventila<strong>to</strong>r. The coefficient of discharge takes in<strong>to</strong> account any obstructions in the naturalsmoke and heat exhaust ventila<strong>to</strong>r such as controls, louvres, and vanes without the influence of side winds.Fire open positionTarget opening position of smoke and heat exhaust ventila<strong>to</strong>rs <strong>to</strong> be achieved and sustained while venting smokeand heat.Geometric area (Av)Opening area of a natural smoke and heat exhaust ventila<strong>to</strong>r. Controls, louvres and other obstructions are nottaken in<strong>to</strong> account.Geometric free areaSmallest cross sectional area of a ventila<strong>to</strong>r through which flow occurs.Manual activationInitiation of the operation of a smoke and heat exhaust ventila<strong>to</strong>r by a human action (e.g. by pressing a but<strong>to</strong>nor pulling a handle).46Section E

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!