13.07.2015 Views

LV generator protection - engineering site - Schneider Electric

LV generator protection - engineering site - Schneider Electric

LV generator protection - engineering site - Schneider Electric

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

E88760POWERLOGIC System Manager DemoFile Edit View Setup Control Display ToolsReports Window HelpTime% FundamentalReady1,201,000,800,600,400,200,00EventSampling Mode : MANUALPhase A-N Voltage - Harmonics Analysis5 secondsModuleH2 H3 H4 H5 H6 H7 H8 H9 H10 H11 H12HarmonicsFundamental:RMS:RMS-H:Peak:CF:THD:Phase 1-NHarmonics(RMS)H1: 118.09H2: 0.01H3: 0.45H4: 0.03H5: 0.45H6: 0.04H7: 1.27H8: 0.05H9: 0.42H10: 0.01H11: 1.03H12: 0.07ONLINE: DEMO No working system 9:30OKOverview of functionsThe Masterpact circuit breakers and switch-disconnectors are compatible withthe Digipact or Modbus COM option.The COM option may be used with all types of control units to:b identify the deviceb indicate status conditionsb control the device.Depending on the different types of Micrologic (A, P, H) control units, the COMoption also offers:b setting of the <strong>protection</strong> and alarms functionsb analysis of the AC-power parameters for operating-assistance andmaintenance purposes.switch-disconnectorcircuit breaker withwith communic. bus communication busDigipact Modbus Digipact Modbusdevice identificationaddress b b A P H A P Hcalibre - - A P H A P Htype of device - - P Htype of control unit - - A P H A P Htype of long-time rating plug - - A P H A P Hstatus indicationsON/OFF OF b b A P H A P Hspring charged CH b b A P H A P Hready to close PF b b A P H A P Hfault-trip SDE - - A P H A P Hconnected/disconnected/test b b A P H A P Hposition CE/CD/CTcontrolsON/OFF MX/XF b b A P H A P Hspring charging - -reset of the mechanical - -indicator<strong>protection</strong>s and alarms settingsreading of <strong>protection</strong>s settings A P H A P Hwriting of fine settings in the range P Himposed by the adjustment dialsreading/writing of alarms (délestage, relestage, M2C…) P Hreading/writing of alarms personnalisablesHoperating and maintenance aidsmeasurement:current A P H A P Hvoltages, frequency, power, etc. P H P Hpower quality: fundamental, harmonicsHprogramming of demand metering P Hfault readings:type of fault A P Hinterrupted current P Hwaveform capture:on faultsHon demand or programmedHhistories and logs:trip history P Halarm history P Hevent logs P Hindicators:counter operation A P H A P Hcontact wear P Hmaintenance register P HNote:See the description of the Micrologic control units for further details on <strong>protection</strong>and alarms, measurements, waveform capture, histories, logs and maintenanceindicators.73

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!