CTCDCE6.3. CommunicationcharacteristicsMasterpact NT / NW056431siIn shortThe COM option is required forintegration of the circuit breaker or switchdisconnectorin a supervision system.Masterpact uses the Digipact or Modbuscommunications protocol for fullcompatibility with the SMS PowerLogicelectrical-installation managementsystems. An external gateway is availablefor communication on other networks:b Profibusb Ethernet…Digipact "device"communication module.For fixed devices, the COM option is made up of:b a "device" communication module, installed behind the Micrologic control unitand supplied with its set of sensors (OF, SDE ,PF and CH micro-contacts) andits kit for connection to XF and MX communicating voltage releases.For drawout devices, the COM option is made up of:b a "device" communication module, installed behind the Micrologic control unitand supplied with its set of sensors (OF, SDE, PF and CH micro-contacts) andits kit for connection to XF and MX communicating voltage releasesb a "chassis" communication module supplied separately with its set of sensors(CE, CD and CT contacts).Status indication by the COM option is independent of the device indicationcontacts. These contacts remain available for conventional uses.Digipact or Modbus "Device" communication moduleThis module is independent of the control unit. It receives and transmitsinformation on the communication network. An infra-red link transmits databetween the control unit and the communication module.Consumption: 30 mA, 24 V.Digipact or Modbus "chassis" communication moduleThis module is independent of the control unit. With Modbus "chassis"communication module, this module makes it possible to address the chassisand to maintain the address when the circuit breaker is in the disconnectedposition.Consumption: 30 mA, 24 V.XF and MX communicating voltage releasesThe XF and MX communicating voltage releases are equipped for connection tothe "device" communication module.The remote-tripping function (second MX or MN) are independent of thecommunication option. They are not equipped for connection to the "device"communication module.056401siDigipact "chassis"communication module.E88758Ecommunicationbus2CCM modbus+ ++OFSDEPFCHCDCCTMXXFCE45056431siModbus "device"communication module.13E45183siModbus "chassis"communication module.1 "Device" communication module : hard wire2 "Chassis" communication module : communication bus3 OF, SDE, PF and CH "device" sensors4 CE, CD and CT "chassis" sensors5 MX and XF release.Note:Eco COM is limited to the transmission of metering data and does not allow thecontrol of the circuit breaker.72

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!