Literature - Lochinvar

Literature - Lochinvar Literature - Lochinvar

lochinvar.com
from lochinvar.com More from this publisher
13.07.2015 Views

The Ultimate Water Heater OperatingControl with Graphic LCD DisplayWater heaters with different inputs can be cascadedtogether to maximize turndown capabilityCompatibility with Copper-Fin II ® non-condensingwater heater to create a front end loading systemNight Setback Capabilities> Setback of Storage Tank TemperatureWater heater pump control> Pump delay with freeze protection> Building Recirculation Pump Control*> Pump exerciseHigh-voltage terminal strip> 110 Vac input to water heater> Dry Contacts for Water Heater Pump Control> Dry Contacts for Building Recirc. Pump Control *Low-voltage terminal stripwith 28 points of connection> 0-10 VDC Water Heater Rate Output> 0-10 VDC Heat Demand Input> Modbus ContactsUSB Connection Point for optionalSMART SYSTEM PC software withadvanced setup and diagnosticsModbus Compatibility (Optional)Long-Lasting “Life Cycle” Efficiency* Exclusive to Lochinvar Smart SystemIn a standard tank-type water heater, lime scale builds up over time on important heat transfer surfaces, insulating the waterfrom the heat source. This buildup in the bottom of the tank and around the flue tubes can cause tank-type heaters to fail inas little as 2-3 years. This decreases thermal efficiency and increases operating cost. Just 1/4" of lime scale in the tank canincrease operating costs as much as 25%!ARMOR’s “Better Idea” concept eliminates the impact of lime scale, maintaining a high-rated thermal efficiency and lowoperating cost throughout its long life cycle.The chart below illustrates how ARMOR is a better way, delivering true “life cycle efficiency” compared to standard tank-type units.Efficiency Loss Due to Lime Scale Buildup100%Traditional tank-type water heater fluetubes with nearly 6" of lime scale buildupStandardTank-Types90%80%70%60%50%40%30%20%10%0%0 12 3 4 5lexible Venting Options - Up to 100 feet of air intake and 100 feet of exhaust vent with PVC, CPVC, Polypropylene or SS.ARMOR offers 5 ventingoptions and tremendousflexibility for placement ofunits within the building,because it permits direct-ventair intake and exhaust runsup to 100 equivalent feet using either PVC,CPVC, Polypropylene or AL29-4C stainlesssteel vent pipe. Intake and exhaust runscan terminate horizontally through asidewall or vertically through the roof.Direct Vent SidewallDirect Vent VerticalVertical w/Sidewall AirConcentric Direct VentVerticalConcentric Direct VentSidewall

The Ultimate Water Heater OperatingControl with Graphic LCD DisplayWater heaters with different inputs can be cascadedtogether to maximize turndown capabilityCompatibility with Copper-Fin II ® non-condensingwater heater to create a front end loading systemNight Setback Capabilities> Setback of Storage Tank TemperatureWater heater pump control> Pump delay with freeze protection> Building Recirculation Pump Control*> Pump exerciseHigh-voltage terminal strip> 110 Vac input to water heater> Dry Contacts for Water Heater Pump Control> Dry Contacts for Building Recirc. Pump Control *Low-voltage terminal stripwith 28 points of connection> 0-10 VDC Water Heater Rate Output> 0-10 VDC Heat Demand Input> Modbus ContactsUSB Connection Point for optionalSMART SYSTEM PC software withadvanced setup and diagnosticsModbus Compatibility (Optional)Long-Lasting “Life Cycle” Efficiency* Exclusive to <strong>Lochinvar</strong> Smart SystemIn a standard tank-type water heater, lime scale builds up over time on important heat transfer surfaces, insulating the waterfrom the heat source. This buildup in the bottom of the tank and around the flue tubes can cause tank-type heaters to fail inas little as 2-3 years. This decreases thermal efficiency and increases operating cost. Just 1/4" of lime scale in the tank canincrease operating costs as much as 25%!ARMOR’s “Better Idea” concept eliminates the impact of lime scale, maintaining a high-rated thermal efficiency and lowoperating cost throughout its long life cycle.The chart below illustrates how ARMOR is a better way, delivering true “life cycle efficiency” compared to standard tank-type units.Efficiency Loss Due to Lime Scale Buildup100%Traditional tank-type water heater fluetubes with nearly 6" of lime scale buildupStandardTank-Types90%80%70%60%50%40%30%20%10%0%0 12 3 4 5lexible Venting Options - Up to 100 feet of air intake and 100 feet of exhaust vent with PVC, CPVC, Polypropylene or SS.ARMOR offers 5 ventingoptions and tremendousflexibility for placement ofunits within the building,because it permits direct-ventair intake and exhaust runsup to 100 equivalent feet using either PVC,CPVC, Polypropylene or AL29-4C stainlesssteel vent pipe. Intake and exhaust runscan terminate horizontally through asidewall or vertically through the roof.Direct Vent SidewallDirect Vent VerticalVertical w/Sidewall AirConcentric Direct VentVerticalConcentric Direct VentSidewall

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!