NOTE: MAXON recommends usingdielectric grease on all electricalconnections.3. Disconnect the white wire (FIG. 15-1) fromstarter solenoid. Lower the platform whiledraining the remaining hydraulic fl uid fromsystem. Reinstall drain plug. Reconnect thewhite wire to starter solenoid.4. Pull out (no threads) fi ller cap (FIG.15-2). Add 1 gallon of hydraulic fl uidto reservoir. The reservoir should lookabout half full (FIG. 15-2). Reinstallfi ller cap (FIG. 15-2).5. Stow the lift and do the CHECKINGHYDRAULIC FLUID procedure in thissection of the manual.CAUTIONPump cover must be correctly securedto prevent it from becominga hazard. To secure pump cover,the long side of the holder flatsmust butt against pump cover asshown in the illustration.HEXNUTDISCONNECTING WHITE WIREFIG. 15-1POWERUNIT(REF)FILLERCAPPOWER UNITFIG. 15-2STARTERSOLENOIDWHITEWIRERESERVOIRDRAIN PLUGHALFFULLLONG SIDE OFHOLDER FLATSBUTT AGAINSTCOVER11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-77136. Bolt on the pump cover as shown inFIG. 15-3. Torque the 5/16”-18 coverbolts from 10 to 14 lb-ft.HEX NUTS(2 PLACES) FLATWASHERS(2 PLACES)PUMPCOVERCAP SCREWS(2 PLACES)BOLTING ON PUMP COVERFIG. 15-315