13.07.2015 Views

ESL 429/449 Series - eANIXTER

ESL 429/449 Series - eANIXTER

ESL 429/449 Series - eANIXTER

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Product Selection Guide<strong>Series</strong>DesignatorModel DesignatorFeatures<strong>449</strong>CSRTWire Type Model Designator Power DesignatorNumber Description Designator Listing Designator Power2 Two-wire only 9 UL A 6/12 VDC4 Four-wire only C 12/24 VDCWire TypePower DesignatorFeaturesDesignator Feature DescriptionE End-of-Line Power Built-in end-of-line relay that also acts as a sensitivity status output. For four-wire only. Fail-safeSupervisory and relay trips upon loss of power or if smoke detector is outside the approved sensitivity range forSensitivity Status more than one day. End-of-line resistor is easily connected to terminal with no extra wiring, orRelayrelay contacts can be connected to a separate trouble loop.H Isolated Fixed Temp. Isolated fixed 135°F (57°C) and rate-of-rise heat detector, independently trips the LED and alarmand Rate-of-Rise relay output. Smoke detector activates internal sounder (local alarm) and auxiliary relay, but doesHeat Detectornot latch. Approved as both single station smoke alarm and system heat detector.R Auxiliary Relay Used to activate other devices such as elevator recall, door holders, etc. UL Listed for releasing services.S Built-in Sounder 85db built-in sounder alarms when smoke is detected or when power wiring polarity is reversed.T Integrated Fixed Temp. Integrated fixed 135°F (57°C) temp. and rate-of-rise heat detector offers double protection.and Rate-of-Rise Either heat detector or smoke detector can trip and latch LED and alarm relay outputs.Heat DetectorElectrical SpecificationsModel 2-Wire 4-Wire Min.Volt. Max.Volt. Max. Ripple Typ.Avg.Stby. Typ. Alarm Cur. Typ.Avg. Pol. Alarm Relay Other Relay(PK to PK) Cur. (12-24V) (12-24V) Rev.Cur. Contacts Contacts(V) (uA) (mA) (mA) (A) (A)<strong>429</strong>AT * 6.5 20 10% 70 *see S09A - - -<strong>429</strong>C * 8.5 33 10% 70 *see S10A - - -<strong>429</strong>CT * 8.5 33 10% 70 *see S10A - - -<strong>429</strong>CRT * 8.5 33 10% 70 *see S11A - - 2<strong>429</strong>CST * 8.5 33 10% 70 *see S11A 10 - -<strong>449</strong>C * 8.5 33 10% 70 15 - 0.5 -<strong>449</strong>CT * 8.5 33 10% 70 15 - 0.5 -<strong>449</strong>CRT * 8.5 33 10% 70 31 - 0.5 -<strong>449</strong>AT * 5.1 27 10% 70 15 - 0.5 -<strong>449</strong>CST * 8.5 33 10% 70 40 10 0.5 -<strong>449</strong>CSRT * 8.5 33 10% 70 51 10 0.5 2<strong>449</strong>CSRH ** * 8.5 33 10% 70 51 10 0.5 2<strong>449</strong>CSTE * 8.5 33 10% 23mA 51 33 0.5 2<strong>449</strong>CTE * 8.5 33 10% 23mA 31 23 0.5 2Power Supervision UnitsModel Min.Volt. Max. Volt. Typ. Avg. Stby.Cur.(uA) Relay Contacts (A)204-6V (UL Listed) 5.1 15 33mA @ 6VDC 0.5204-12/24V (UL Listed) 8.5 33 14mA @ 12VDC, 28mA @ 24VDC 0.5AccessoriesSM-200Smoke! in a can® canned smoke for functional testing of smoke detectorsSM-EXT1 Smoke! in a can® extension accessory211 Replacement optical blocks (set of 10)241 Terminal block for 4-wire smoke detectors <strong>449</strong>CTE, <strong>449</strong>CSTE, <strong>449</strong>AT, <strong>449</strong>C, <strong>449</strong>CT,<strong>449</strong>CST* <strong>429</strong> models draw up to a maximum of 60mA current if not limited by panel.** <strong>449</strong>CSRH model is a smoke alarm with isolated heat detector.Certain items in the installation instructions are protected under one or more of the following patents: 5,546,074; 5,798,701; 5,821,666;6,756,906SpecificationsOperating temperature ................... ...32°F to 100°F (0°C to 38°C)Operating humidity range ....................... 0 to 95% non-condensingSounder specifications ............................................ 85dB at 10 feetField wiring size ............................................................ 14-24 AWGSelf-diagnostic indication .................. typically 27 hours after reset(do not connect power supply that resets every 24 hours)Heat detector .................. fixed temp 135°F, 50 foot (15m) spacingrate-of-rise 15°F/min > 105°F (8°C/min > 41°C)Auxiliary relay contacts ........ 2A @ 28VDC or 120VAC (resistive)Alarm contacts .................................. 500mA @ 36VDC (resistive)Dimensions ................. 6.1” (15.5cm) diameter x 1.9” (4.7cm) deepWeight ..................................................................... 8.8 oz. (0.25kg)Color ....................................................................................... whiteGE Security12345 SW Leveton DriveTualatin, OR 97062503-692-4052USA & Canada: 800-547-2556Tech Support: 800-648-7424www.ge-security.com14153D / September 2004

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!