4 - PHYSICAL DATA30RY 017 021 026 033 040 050 060 070 080Net nominal cooling capacity, single pump* kW 18.6 23.1 26 31.8 39.3 50 58 68 79Net nominal cooling capacity, dual pump* kW - - - - 38.1 49 57 67 79Operating weightkg<strong>with</strong> hydronic module, single pump 386 416 436 451 510 572 587 638 675<strong>with</strong> hydronic module, dual pump - - - - 590 652 667 718 752Operating weight <strong>with</strong>out hydronic module kg 361 391 411 426 486 548 563 614 649Refrigerant charge R-407C kg 6.6 6.3 7.45 7.85 9.75 11.1 11.8 13.3 17.0CompressorsHermetic, scroll 48.3 r/sQuantity 1 1 1 1 1 2 2 2 2Number of capacity steps 1 1 1 1 1 2 2 2 2Minimum capacity % 100 100 100 100 100 46 42 50 50Control typePRO-DIALOG PlusCondensersGrooved copper tubes and aluminium finsFanAxial fan <strong>with</strong> available static pressureQuantity 1 1 1 1 1 1 1 1 1Available static presure Pa 100 100 100 100 150 150 150 150 150Air flow (high speed) l/s 1940 1940 1940 2500 3890 3890 4720 5830 5830Speed (high/low) r/s 24/12 24/12 24/12 24/12 24/12 24/12 24/12 24/12 24/12EvaporatorWelded, direct-expansion plate heat exchangerWater volume l 1.6 2.0 2.3 3.0 3.6 4.6 5.9 6.5 7.6Max. water-side operating pressurekPa<strong>with</strong> hydronic module 250 250 250 250 300 300 300 300 300<strong>with</strong>out hydronic module 1000 1000 1000 1000 1000 1000 1000 1000 1000<strong>Hydronic</strong> modulePump, safety valve, expansion tank, flow switch and flow control valve.Screen filter, pressure gauges,Victaulic screen filter, pressure gauge,purge valvespurge valves (air and water)Pump, single, centrifugal Multicell pump, 48.3 r/s Composite monocell pump, 48.3 r/sQuantity 1 1 1 1 1 1 1 1 1Expansion tank volume l 8 8 8 8 12 12 12 12 12Water connection type Threaded male conical gas connection Victaulic (sleeves for welded or screw connection(<strong>with</strong> or <strong>with</strong>out hydronic module) supplied)Diameter in 1-1/4 1-1/4 1-1/4 1-1/4 2 2 2 2 2Outside tube diameter in 1-1/4 1-1/4 1-1/4 1-1/4 2 2 2 2 2mm 42.4 42.4 42.4 42.4 60.3 60.3 60.3 60.3 60.3* Net nominal cooling capacity based on Eurovent conditions = gross cooling capacity plus the capacity corresponding to the available pressure (flow x pressure/0.3)Standard EUROVENT conditions: evaporator entering/leaving water = 12°C/7°C, outdoor air temperature = 35°C5 - ELECTRICAL DATA30RY 017 021 026 033 040 050 060 070 080Power circuitNominal voltage V-ph-Hz 400-3-50Voltage range V 360-440Control circuit supplyThe control circuit is supplied via the transformer installed on the unitMaximum unit power input* kW 9.78 12.05 13.75 17.35 21 25.3 31.1 36.8 42.9Nominal unit current draw** A 15.1 17.8 19.91 26.3 30.9 36.5 46.8 56.2 62.5Maximum unit current draw*** A 17.2 21 23.7 29.9 35.9 43.5 53.9 63.4 72.4Maximum start-up currentAStandard unit† 89.8 133.8 133.8 139.4 181.4 153.6 163.4 172.9 217.9Unit <strong>with</strong> electronic starter (option)‡ - - - - 120.1 108.1 116.2 125.7 156.7Three-phase short-circuit holding current kA 10 10 10 10 10 10 10 10 10* Power input, compressor(s) + fan(s) + pump, at max. unit operating conditions (water entering/leaving temperature = 15°C/10°C and a maximum air enteringtemperature of 45°C ± 1 K depending on the unit size and at a nominal voltage of 400 V) - (values given on the unit name plate).** Nominal unit operating current draw at standard Eurovent conditions: evaporator entering/leaving water = 12°C/7°C, outdoor air temperature = 35°C. The currentvalues are given for a nominal voltage of 400 V (values given on the unit name plate).*** Maximum unit operating current at maximum unit power input and 400 V (data shown on the unit name plate).† Maximum instantaneous starting current at 400 V nominal voltage (maximum operating current of the smallest compressors + fan current + pump current + lockedrotor current of the largest compressor).‡ Maximum instantaneous starting current at 400 V nominal voltage and <strong>with</strong> compressor <strong>with</strong> electronic starter (maximum operating current of the smallestcompressor(s) + fan current + pump current + reduced start-up current of the largest compressor).10

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!