Oocyte Clamps Electrophysiology Oocyte Clamp OC-725C

Oocyte Clamps Electrophysiology Oocyte Clamp OC-725C Oocyte Clamps Electrophysiology Oocyte Clamp OC-725C

13.07.2015 Views

Oocyte ClampsNEWHAI 118 Data Acquisition SystemSettingsSettings or templates for various experiments are stored in the programssettings menu. This makes changing program settings toaccommodate different experiments point-and- click easy.Applications Supported:Oocyte clampLabScribe’s gain telegraph feature automatically calibrates the softwareto any Warner Instruments Oocyte Clamp so that the main displayreads in current and voltage. The on board stimulator includesa flexible voltage clamp protocol so an external stimulator is notrequired. Finally, the digital output capability of the HAI 118 alsoadds the ability to automate your Oocyte rig.Epithelial ClampOutput from Warner Instruments or other epithelial voltage clampscan be fed directly into the HAI 118. The voltage clamp protocol inthe LabScribe program’s stimulator section makes recordings of fourto six channels of epithelial data possible.Blood Flow and Blood pressureBlood flow data from doppler devices and blood pressure signalsfrom available transducer amplifiers can be fed directly into the HAI118. Analytical features in the LabScribe software can give beat-tobeatrate, systolic, diastolic and mean pressures, as well as dP/dt.Hemodynamic StudiesBlood pressure signals from available transducer amplifiers can befed directly into the HAI 118. Analytical features in the LabScribesoftware can display beat-to-beat rate, systolic, diastolic and meanpressures as well as dP/dt. Up to 8 channels of pressure data can berecorded and the high speed nature of the hardware makes it idealfor use with rapid heart rate animals such as mice.Electrophysiology.The high speed nature of the HAI 118 make it perfect for studiesinvolving blood pressure and sympathetic nerve activity as well as alltypes of cardiac electrophysiology, even in rapid heart rate animalssuch as mice where extra speed is required.SpecificationsInput:Number of Inputs8 single ended BNCInput Impedance1 MInput Range±10 VNoise1 mV typicalGain TelegraphSoftware or hardware 8 bitOutput:Number of DACs 2DAC Resolution12 bitDAC Speed100 k s/sec independent of sample speedDAC Output Range ±10 VDigital Output Lines 8 TTLDigital Output Connector BNCA/D Converter:Sample Speed1 S/sec-100 k S/secResolution16 bitInterfaceUSBTrigger/Digital Input Lines 4, TTLEnclosureAluminumPower120/220 VAC, 60/50 Hz, CE compliantTrigger ModesDisplayDAC ModesDAC Performance:Pulse WidthFrequencyCatalog No. $ ProductExternal trigger, Threshold trigger from data,User triggerReal time, User definable screen time independentof sample rate. User definable units, AutoScale,Full Scale or User defined scalePulse, Train, Step, DC, Custom0.01 msec to 6500 msec (Pulse mode)0.2 Hz to 50 kHz (Pulse Mode)BS4 69-3130 4,155.00 HAI 118 Data Acquisition SystemElectrophysiologyFor Microscopes, see pages M149 - M150.For Micro-Incubators, see pages M80 - M97.For Microinjectors, see pages M70 - M77.For Micromanipulators, see pages M186 - M201.For OC-725C Oocyte Clamp,see pages H20 - H21.For Oocyte Recording Chambers,see pages H22 - H23.For a Complete Oocyte Two-ElectrodeVoltage Clamp Workstation, see page H26.U.S. Toll Free: (800) 272-2775 • Fax: (508) 429-5732 • Online: www.harvardapparatus.comH25

Oocyte ClampsNEWOocyte Two-Electrode Voltage Clamp Workstation TEV700BS4 64-0034 TEV700 Oocyte Two-Electrode Voltage Clamp Work StationSpecialized Tools For Bioresearch• Oocyte Clamp OC-725C,see pages H20 - H21• RC-3Z Oocyte Chamber,see page H23• MM-33L Manipulator,see page M190• MM-33R Manipulator,see page M190• MB/B Magnetic Base,see page M201The TEV700 Workstation provides many of the necessary components typically used with the OC-725C voltageclamp. When these components are purchased with the OC-725 Oocyte Clamp, the complete package isdiscounted as shown. The individual components of the system are listed below.Catalog No. $ Model ProductBS4 64-0034 6,125.00 TEV700 Complete Oocyte Two-Electrode Voltage Clamp Work StationSystem ComponentsBS4 64-0028 4,615.00 OC-725C Oocyte ClampBS4 64-0319 293.00 RC-3Z Oocyte ChamberBS4 64-0055 765.00 MM-33L Left ManipulatorBS4 64-0056 765.00 MM-33R Right ManipulatorBS4 64-0060 53.00 MB/B Magnetic Base, must purchase 2 for complete systemFor Glass Capillaries, see pages M45 - M50.For Pipette Pullers, see pages M51 - M54.For HAI 118 Data Acquisition System forOocyte Clamping, see pages H24 - H25.For Oocyte Injection, see the PLI-100and PLI-90 on pages M72 - M74.H2611,000 Specialty Products to Enhance Your Bioresearch

<strong>Oocyte</strong> <strong><strong>Clamp</strong>s</strong>NEW<strong>Oocyte</strong> Two-Electrode Voltage <strong>Clamp</strong> Workstation TEV700BS4 64-0034 TEV700 <strong>Oocyte</strong> Two-Electrode Voltage <strong>Clamp</strong> Work StationSpecialized Tools For Bioresearch• <strong>Oocyte</strong> <strong>Clamp</strong> <strong>OC</strong>-<strong>725C</strong>,see pages H20 - H21• RC-3Z <strong>Oocyte</strong> Chamber,see page H23• MM-33L Manipulator,see page M190• MM-33R Manipulator,see page M190• MB/B Magnetic Base,see page M201The TEV700 Workstation provides many of the necessary components typically used with the <strong>OC</strong>-<strong>725C</strong> voltageclamp. When these components are purchased with the <strong>OC</strong>-725 <strong>Oocyte</strong> <strong>Clamp</strong>, the complete package isdiscounted as shown. The individual components of the system are listed below.Catalog No. $ Model ProductBS4 64-0034 6,125.00 TEV700 Complete <strong>Oocyte</strong> Two-Electrode Voltage <strong>Clamp</strong> Work StationSystem ComponentsBS4 64-0028 4,615.00 <strong>OC</strong>-<strong>725C</strong> <strong>Oocyte</strong> <strong>Clamp</strong>BS4 64-0319 293.00 RC-3Z <strong>Oocyte</strong> ChamberBS4 64-0055 765.00 MM-33L Left ManipulatorBS4 64-0056 765.00 MM-33R Right ManipulatorBS4 64-0060 53.00 MB/B Magnetic Base, must purchase 2 for complete systemFor Glass Capillaries, see pages M45 - M50.For Pipette Pullers, see pages M51 - M54.For HAI 118 Data Acquisition System for<strong>Oocyte</strong> <strong>Clamp</strong>ing, see pages H24 - H25.For <strong>Oocyte</strong> Injection, see the PLI-100and PLI-90 on pages M72 - M74.H2611,000 Specialty Products to Enhance Your Bioresearch

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!