5.2 CONNECTOR FUNCTION DETAILSThe following describes the functions of the 6 connectors on the rear of the module. See rear panellayout FIG 5.PLUG “A” 18 WAYPIN DESCRIPTIONNo1 Oil pressure sender +ve connection. If a digital oil pressure switch is being usedinstead, connect to this pin and ground the other side of the switch.2 Oil pressure sender -ve connection. Only use if using analogue sender3 Oil pressure sender -ve feed. Connect to pin 2 if using insulated return typesenders.4 Fuel level sender +ve. If a digital fuel level switch is being used instead, connectto this pin and ground the other side of the switch.5 Fuel level sender -ve connection. Only use if using analogue sender6 Fuel level sender -ve feed. Connect to pin 2 if using insulated return type senders.7 Engine coolant temp sender +ve connection. If a digital temperature switch isbeing used instead, connect to this pin and ground the other side of the switch.8 Engine coolant temp sender -ve connection. Only use if using analogue sender9 Engine coolant temp sender -ve feed. Connect to pin 2 if using insulated returntype senders.10 Engine oil temp sender +ve connection. If a digital temperature switch is beingused instead, connect to this pin and ground the other side of the switch.11 Engine oil temp sender -ve connection. Only use if using analogue sender12 Engine oil temp sender -ve feed. Connect to pin 2 if using insulated return typesenders.13 DO NOT USE14 Generator L1 current transformer connection.15 Generator L2 current transformer connection. If single phase is used do notconnect this pin.16 Generator L3 current transformer connection. If single phase is used do notconnect this pin.17 Generator current transformer common connection, only to be used if a neutral CTis fitted.18 Generator current transformer Neutral connection. If no neutral CT is fitted use thispin as CT Common.PLUG “B” 15 WAYPIN DESCRIPTIONNo19 Output 8 Normally closed change-over contact. Normally a spare auxiliary output.However if breaker control scheme is being used this is used for the Mains ACBclose connection.20 Output 8 Common change-over contact.21 Output 8 Normally open change-over contact22 DO NOT USE23 Output 7 Normally closed change-over contact. Normally a spare auxiliary output.However if breaker control scheme is being used this is used for the Mains ACBshunt trip or UV coil connection.24 Output 7 Common change-over contact.25 Output 7 Normally open change-over contact.26 DO NOT USE27 Output 6 Normally closed change-over contact.28 Output 6 Common change-over contact.606 OPERATING MANUAL ISSUE 2 11/27/00 MR25

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!