13.07.2015 Views

D-157 - Reliance Electric

D-157 - Reliance Electric

D-157 - Reliance Electric

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

RMI Terminal Strip41. Digital Input 142. Digital Input 243. Digital Input 344. Digital Input 445. Digital Input +24 Vdc46. Digital Output External +24 Vdc47. Digital Output 148. Digital Output 249. Digital Output 350. Digital Output 451. Digital Output Common52. Relay 1 Common53. Relay 1 N.O.54. Relay 2 N.C.55. Relay 2 Common56. Relay 2 N.O.57. Not Used58. Relay 3 N.C.59. Relay 3 Common60. Relay 3 N.O.61. Not Used62. Analog Input 0 – 10 Vdc63. Analog Input 0 – 20 mA64. Analog Input Common65. Analog Output 1: 0 to 10 Vdc66. Analog Output 2: +/- 10 Vdc67. Analog Output 3: 0 to 10 Vdc; 0 to 20 mA68. Analog Output Common69. Frequency Input: 0 to 200 kHzGV3000/SE AC DriveQuick ReferenceVersion 6.06Refer to the following manual for detailed informationabout the Super Remote Meter Interface (RMI) board:• D2-3341 Super Remote Meter Interface (RMI)Board for use with GV3000/SE andVTAC 7 DrivesD-<strong>157</strong>-2


General ParametersP.000 Control SourceP.001 Accel Time 1 (Ramp 1)P.002 Decel Time 1 (Ramp 1)P.003 Minimum SpeedP.004 Maximum SpeedP.005 Current LimitP.006 Second Menu PasswordP.007 TS Digital Inputs ConfigP.008 TS Speed Ref SourceP.009 TS Analog Input OffsetP.010 TS Analog Input GainP.011 TS Analog Input ConfigP.012 TS Analog Output SourceP.013 Output Relay ConfigP.014 Trim Ref SourceP.015 Trim Gain PercentageP.016 Draw Gain PercentageP.017 Accel Time 2 (Ramp 2)P.018 Decel Time 2 (Ramp 2)P.019 S-Curve EnableP.020 Jog Speed RefP.021 Jog Ramp Accel TimeP.022 Jog Ramp Decel TimeP.023 MOP Acc/Dec TimeP.024 MOP Reset ConfigurationP.025 Stop TypeP.026 Function Loss ResponseP.027 Fwd/Rev ConfigurationP.028 Speed Display ScalingP.029 Elapsed Time MeterP.030 Elapsed Time Meter ResetP.031 Preset Speed 1P.032 Preset Speed 2P.033 Preset Speed 3P.034 Preset Speed 4P.035 Preset Speed 5P.036 Preset Speed 6P.037 Preset Speed 7P.038 Preset Speed 8P.039 Encoder Loss EnableP.040 Motor Overload EnableP.041 Motor Overload TypeP.042 Line Dip Ride-Through TimeP.043 Fault Auto Reset AttemptsP.044 Fault Auto Reset TimeP.045 Output Phase Loss EnableP.047 Carrier FrequencyP.048 Volts/Hertz or Vector RegulationP.049 Country DefaultsGeneral Parameters (Continued)P.050 Restore DefaultsP.051 Programming DisableP.052 AUTO/MAN Key DisableP.053 Manual Ref Preset EnableP.054 Level Sense Start EnableP.055 STOP/RESET Key DisableP.060 Network Drop NumberP.061 Network Connection TypeP.062 Comm Loss ResponseP.063 Network Ref SourceP.064 Network Trim Ref SourceP.065 Option Port: Type and VersionP.066 Network Output Reg 1 Source ________P.067 Network Output Reg 2 Source ________P.068 Network Output Reg 3 Source ________P.069 Network Output Reg 4 Source ________P.090 Diagnostics SourceP.091 Diagnostics DisplayP.095 Power Module Output AmpsP.098 Software Version NumberP.099 Power Module TypeVolts/Hertz ParametersH.000 Motor Nameplate VoltsH.001 Motor Nameplate Base FreqH.002 Motor Nameplate AmpsH.003 Torque Boost VoltageH.004 Slip CompensationH.005 DC Braking EnableH.006 DC Braking Start FreqH.007 DC Braking CurrentH.008 DC Braking TimeH.009 Avoidance Freq EnableH.010 Avoidance Freq Midpoint 1H.011 Avoidance Freq Band 1H.012 Avoidance Freq Midpoint 2H.013 Avoidance Freq Band 2H.014 Avoidance Freq Midpoint 3H.015 Avoidance Freq Band 3H.016 Sync DirectionH.017 Input Power/Snubber ConfigH.018 V/Hz Curve TypeH.019 Identification ResultH.020 Identification RequestH.021 AC Line VoltsH.022 Overfrequency Limit


Vector ParametersU.000 Torque Ref SourceU.001 Encoder PPRU.002 Motor PolesU.003 Motor Nameplate Base FreqU.004 Motor Nameplate AmpsU.005 Motor Nameplate RPMU.006 Magnetizing CurrentU.007 Motor Nameplate VoltsU.008 Torque Self-Tune EnableU.009 Torque Self-Tune ResultU.012 Speed Reg Prop GainU.013 Speed Reg Integral GainU.014 Torque Reg Prop GainU.015 Torque Reg Integral GainU.016 Field Weakening Start RPMU.017 Motor Top SpeedU.018 AC Line VoltsU.019 Flux Curr Reg Prop GainU.020 Flux Curr Reg Int GainU.021 Rotor Time ConstU.022 Motor Nameplate HorsepowerU.023 Low DC Bus Fault AvoidanceU.024 High DC Bus Fault AvoidanceU.025 Zero Speed Hold TimeU.026 Current Compounding GainU.027 Inertia Compensation GainU.028 Losses Compensation GainU.030 SVC Slip Adjust ________U.031 SVC Sync DirectionU.032 SVC Flux Curr Reg GainU.040 OCL Feedback SourceU.041 OCL Lead/Lag SelectU.042 OCL Lead/Lag Low FreqU.043 OCL Lead/Lag RatioU.044 OCL Ref GainU.045 OCL Proportional GainU.046 OCL Integral GainU.047 OCL Trim Range PercentageU.048 OCL Prop Trim EnableRMI Parametersr.001 Analog Output 1 Sourcer.002 Analog Output 1 Offsetr.003 Analog Output 1 Gainr.004 Analog Output 2 Sourcer.005 Analog Output 2 Offsetr.006 Analog Output 2 Gainr.007 Analog Output 3 Sourcer.008 Analog Output 3 Offsetr.009 Analog Output 3 Gainr.010 Analog Input Offsetr.011 Analog Input Gainr.014 Freq Input Sample Periodr.015 Frequency Input Offsetr.016 Frequency Input Gainr.020 PI Regulator Offsetr.021 PI Regulator Prop Gainr.022 PI Regulator Integral Gainr.025 Torque/Current Limit Sourcer.030 Digital Input Configr.031 Digital Output 1 Configr.032 Digital Output 2 Configr.033 Digital Output 3 Configr.034 Digital Output 4 Configr.035 Relay Output 1 Configr.036 Relay Output 2 Configr.037 Relay Output 3 Configr.040 Digital Output 1 Delay Timer.041 Digital Output 2 Delay Timer.042 Digital Output 3 Delay Timer.043 Digital Output 4 Delay Timer.044 Relay Output 1 Delay Timer.045 Relay Output 2 Delay Timer.046 Relay Output 3 Delay Timer.050 Speed Detection Level 1r.051 Speed Detection Level 2r.052 Speed Detection Level 3r.053 Speed Detect Hysteresisr.056 Low Speed Detection Levelr.057 Current Detection Level 1r.058 Current Detection Level 2r.059 Current Detection Level 3 ________r.060 Current Detection Hysteresisr.063 Torque Detection Level 1r.064 Torque Detection Level 2r.065 Torque Detection Level 3r.066 Torque Detection Hysteresis ________


AInHIdcI-AcI-EnLILS-AcS-EnAInbYCCHSECEErELFLHIdHILHUIPLLUnCLnIdOCOCAOCbOCdOFOHOLOPLOSPPUcPUnPUoSFSrlUArUbSAlarm CodesAnalog Input Signal LossHigh DC Bus WarningV/Hz Identification ActiveV/Hz Identification EnabledLow Input LineVector Self-Tuning ActiveVector Self-Tuning EnabledFault CodesAnalog Input Signal LossDC Bus Charging Bypass Not ClosedChecksum ErrorEarth Current Failure (Ground Fault)Non-volatile Memory FailureEncoder LossFunction LossV/Hz Identification AbortedHigh Input LineHigh DC Bus FaultInput Phase LossLow DC Bus FaultNetwork Comm LossV/Hz Identification Not PerformedOvercurrentOvercurrent at AccelerationOvercurrent at DC BrakingOvercurrent at DecelerationOverfrequencyDrive OvertemperatureMotor OverloadMotor Output Phase LossOverspeed (Vector Only)Missing Power Module ID ConnectorPower Module Not IdentifiedPower Module OverloadVector Self-Tuning AbortedSerial Comm LostPC Comm Spurious InterruptAsymmetrical Bus ChargeATTENTION: This material is not intendedto provide operational instructions. Qualifiedelectrical personnel must read andunderstand the applicable instructionmanuals in their entirety prior to installing,adjusting, operating, and servicing thisequipment. Failure to observe thisprecaution could result in severe bodilyinjury or loss of life.Regulator Board Terminal Strip1. RS-232 Transmit*2. RS-232 Receive*3. RS-232 Common*4. Encoder +15 Volts5. Encoder Phase A6. Encoder Phase A Not7. Encoder Phase B8. Encoder Phase B Not9. Encoder Common10. Analog Meter Output11. Analog Meter Common12. Isolated Reference Voltage13. Vdc Analog Speed Reference14. mA Analog Speed Reference15. Isolated Reference Ground16. Digital Input +24 Volts17. Digital Input 8 (Rem/Loc)18. Digital Input 7 (Ramp1/Ramp2)19. Digital Input 6 (Fwd/Rev)20. Function Loss21. Run/Jog22. Reset23. Stop24. Start25. +24 Vdc Common26. Snubber Resistor Braking Output*27. +24 Vdc Common*28. N.C. Relay Contact**29. N.C. Relay Common**30. N.O. Relay Contact**31. N.O. Relay Common***Not available on Bookshelf drives.**Located on remote terminal strip on Bookshelf drives.Refer to the following software (S/W) and hardware (H/W)manuals for detailed information about the GV3000/SE ACdrive.GV3000/SE Drive S/W I/M H/W I/M1 to 400 HP @ 460 VAC D2-3359 D2-336075 to 200 HP @ 460 VAC D2-3391 D2-33921 to 20 HP @ 230 VAC D2-3387 D2-338830 to 100 HP @ 230 VAC D2-3416 D2-34172 to 30 A Bookshelf D2-3426 D2-3427Printed in U.S.A. D-<strong>157</strong>-2 March 2001