User Manual - Polaris S.p.A.
User Manual - Polaris S.p.A. User Manual - Polaris S.p.A.
Operating instructions4.11.2004 Rev. 1.14.3.5 Idle periodsFollow the precautions below if the appliance will be left idle for some time:• Unplug the appliance from the wall socket (outlet);• Remove all foodstuffs from the appliance;• Defrost it and clean the inside;• Leave the door partly open to favour air circulation inside the cabinet and preventunpleasant smells from forming.• Store the appliance in such a way as to avoid that anyone can remain trapped inside.10
Installation4.11.2004 Rev. 1.15. Installation5.1 General information5.2 Transport and storageEnsure that installation is performed according to the instructions given under chapter"Recommendations on how to best operate the appliance (2000/40/EC)", "Installationtips". We remind you that insufficient airflow will certainly result in appliance malfunctionor damage.Once the appliance has been installed, ensure that it is not resting on the power cord.In the event of damage, the power cord should only be replaced by qualified personnelwith a special cable or cable assembly available from the manufacturer.Ensure compliance with all local safety rules in force at the time of installation.Prior to plugging in the appliance, ensure that the power distribution network ratingsmatch the values shown on the appliance’s rating plate.It is absolutely necessary that the appliance be connected to an effective earth (ground)connection. To this end, the power cord plug is equipped with a grounding contact. If thepower socket (outlet) of the system is not grounded (earthed), connect the appliance to aseparate grounding (earthing) system in compliance with applicable regulations in force.Ask for a qualified technician’s advice.The manufacturer declines all responsibility in case of non-compliance with this accidentpreventionrule.You must always be able to disconnect the appliance from power supply; therefore, oncethe appliance has been installed the power socket (outlet) should be easily accessible.If possible, do not unpack the appliance until it is placed near the final installation site. Donot tip it over.If the appliance has been tipped over, wait for a while until oil settles down again.The appliance should always be stored in sheltered areas.If the appliance was stored in a cold place, thus causing the temperature of the refrigerationunit to fall below 0°C (32°F), prior to start using the appliance keep it at room temperaturefor at least one hour so that the refrigeration unit will warm up to +16°C (61°F).Turning on the appliance when temperature is excessively low may result in compressormalfunction.11
- Page 1: FREEZERSA Plus serieBTBTVTYPE: 70,
- Page 4 and 5: 4.11.2004 Rev. 1.1
- Page 6 and 7: 4.11.2004 Rev.5.7.3 Suggestions ...
- Page 8 and 9: General information4.11.2004 Rev. 1
- Page 10 and 11: Safety4.11.2004 Rev. 1.12.2.1 Insta
- Page 12 and 13: Functional description4.11.2004 Rev
- Page 14 and 15: Operating instructions4.11.2004 Rev
- Page 18 and 19: Installation4.11.2004 Rev. 1.15.3 U
- Page 20 and 21: Adjustment instructions4.11.2004 Re
- Page 22 and 23: Adjustment instructions4.11.2004 Re
- Page 24 and 25: Adjustment instructions4.11.2004 Re
- Page 26 and 27: Adjustment instructions4.11.2004 Re
- Page 28 and 29: Adjustment instructions4.11.2004 Re
- Page 30 and 31: Troubleshooting4.11.2004 Rev. 1.124
- Page 32 and 33: Spare parts4.11.2004 Rev. 1.126
- Page 34 and 35: Spare parts4.11.2004 Rev. 1.128
- Page 36 and 37: Spare parts4.11.2004 Rev. 1.130
- Page 38 and 39: Spare parts4.11.2004 Rev. 1.132
- Page 40 and 41: Spare parts4.11.2004 Rev. 1.134
- Page 42 and 43: Spare parts4.11.2004 Rev. 1.136
- Page 44 and 45: Technical specifications4.11.2004 R
- Page 46 and 47: Wiring diagram BT, BTV
- Page 48 and 49: Technical specifications4.11.2004 R
- Page 50 and 51: Technical specifications4.11.2004 R
- Page 52 and 53: Technical specifications4.11.2004 R
- Page 54 and 55: Technical specifications4.11.2004 R
- Page 56 and 57: DICHIARAZIONE DI CONFORMITA’DECLA
- Page 60: M_SPABT_uen11.pdf
Installation4.11.2004 Rev. 1.15. Installation5.1 General information5.2 Transport and storageEnsure that installation is performed according to the instructions given under chapter"Recommendations on how to best operate the appliance (2000/40/EC)", "Installationtips". We remind you that insufficient airflow will certainly result in appliance malfunctionor damage.Once the appliance has been installed, ensure that it is not resting on the power cord.In the event of damage, the power cord should only be replaced by qualified personnelwith a special cable or cable assembly available from the manufacturer.Ensure compliance with all local safety rules in force at the time of installation.Prior to plugging in the appliance, ensure that the power distribution network ratingsmatch the values shown on the appliance’s rating plate.It is absolutely necessary that the appliance be connected to an effective earth (ground)connection. To this end, the power cord plug is equipped with a grounding contact. If thepower socket (outlet) of the system is not grounded (earthed), connect the appliance to aseparate grounding (earthing) system in compliance with applicable regulations in force.Ask for a qualified technician’s advice.The manufacturer declines all responsibility in case of non-compliance with this accidentpreventionrule.You must always be able to disconnect the appliance from power supply; therefore, oncethe appliance has been installed the power socket (outlet) should be easily accessible.If possible, do not unpack the appliance until it is placed near the final installation site. Donot tip it over.If the appliance has been tipped over, wait for a while until oil settles down again.The appliance should always be stored in sheltered areas.If the appliance was stored in a cold place, thus causing the temperature of the refrigerationunit to fall below 0°C (32°F), prior to start using the appliance keep it at room temperaturefor at least one hour so that the refrigeration unit will warm up to +16°C (61°F).Turning on the appliance when temperature is excessively low may result in compressormalfunction.11