13.07.2015 Views

CS375 - DATASHEET - HQ

CS375 - DATASHEET - HQ

CS375 - DATASHEET - HQ

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

eGEInterlogixProduct Data Sheet<strong>CS375</strong>24-zone control panel plastic housingCommunication256 event logPartitioningEvents are reportable to 6 phone numbers and are selectableby partition and/or event. - SIA and Contact ID formats -Supports all major formats - Flexible autotest reports -Failure to communicate reporting - Reports entering/exitingprogramme mode - Will communicate alarm events duringprogramming- Includes date, time, event and partition number.- Up to 4 true partitions - Separate account code for eachpartition - User code assignment to multiple partitionsHardwire zone expansionThe CS 375 is expandable to 24 zones. - CS216 - 16 zoneexpansion module or CS208 - 8 zone expansion module - Canbe mounted up to 800 m from controlWireless zone expansionPower specificationsThe CS 375 can be expanded using an 8 or 16 zone wirelessreceiver. - Up to 24 supervised wireless zones - Keypadannunciation of alarm, tamper, low battery & lost transmitter- 500 mA aux. power w/16.5 V, 25 VA transformerUp to 16 modules can be added to the CS 375 (*)Zone expander module Adding 1 to 16 additional zones to asystem has never been easier until now with the CS216 zoneexpander module Wireless expansion module Wirelessreceivers allow the integration of the most advancedwireless technology with the <strong>CS375</strong>. Up to 24 transmitterscan be mapped to 4 partitions and individually displayed atthe keypad for alarm and all supervisory reports. CS507 - 7output module Flexible mapping from a large library of eventsor combination of events allows the CS507 to become thedirector of lights or home automation with either X-10 orother power outputs. This module also allows multiplescheduling possibilities such as auto-arming, holidayplanning and opening/closing time. Home systems audiomodule The CS534 home systems module can be used tocontrol X10 devices and allows two-way voice/listen-infunctionality.Standard Features• 8 fully programmable zones• Wireless expansion up to 24 zones• Up to 4 partitions• Maximum 8 keypads per partition• Assign zones to one or multiple partitions• 20 customisable pre-configured zone types• Integrated communicator supporting all major formats• Answering machine defeat• 512 event log• Up/download configuration with competitor lockout• On board RS232• Up to 99 user codes + 1 duress code• Automatic arming with auto retry• Dynamic battery test• Telephone line supervision - voltage and current• Two independent entry & exit delay• Built-in siren driver or voltage output• 2-wire or 4-wire smoke detectors• Walk-test mode• Siren supervision and loud speaker output• Hard wired expansion up to 24 zones• Up to 16 modules


<strong>CS375</strong>24-zone control panel plastic housingSpecificationsOperating powerAuxiliary power with 25 VA transformerLoop resistanceFor standard loopFor 2-wire smokesBuilt-in siren driverAlarm current available(if siren driver is not used)Loop responseOperating temperatureDimensions (W x H x D)16.5 VAC, 25 VA500 mA4K7 end-of-line560 Ohm maximum2-tone (temporal & yelp) - for internal siren only2.5 ASelectable 50 msec or 500 msec0° to 49° C395 x 255 x 120 mmOrdering InformationPart No. Description<strong>CS375</strong> 24-zone Control Panel Plastic HousingCS5003 System Software Package for CSX75CS586 Direct Connect Module for CS175/275/575/875 SeriesCS590 RS232 Cable for CS275, CS575 & CS875 220 cmgGEInterlogixhttp://www.GE-interlogix.comAs a company of innovation, GE Interlogix reserves the right to change product specifications without notice. For the latest product specifications, visit GE Interlogix online at www.GE-Interlogix.com or contact your GE Interlogix sales representative.WEBDS-<strong>CS375</strong>-2004-01-7 10:00:36 [NOT RELEASED]

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!