13.07.2015 Views

HYDROFIRM(T) SGFLT - Prysmian Group

HYDROFIRM(T) SGFLT - Prysmian Group

HYDROFIRM(T) SGFLT - Prysmian Group

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ENERGY<strong>HYDROFIRM</strong>(T)<strong>SGFLT</strong>450/750 VDrinking water


Technical DataElectricalparametersThermalparametersTrademarkType designationStandardApplicationRated voltageMaximum permissibleoperation voltage of plantand power systemsAC test voltageCurrent-carrying capacityMaximum permissibleoperating temperature of theconductorMaximum permissible shortcircuittemperature atconductorMinimum permissibletemperaturesMaximum permissible watertemperature<strong>HYDROFIRM</strong>(T)<strong>SGFLT</strong>According to <strong>Prysmian</strong> product specificationFor making connections to electrical equipment used in water and subjected tomedium mechanical stress.The cables can also be used in drinking water, industrial water, cooling water,surface water, rainwater, ground water and sea water (salt water).The outer sheath fulfil the requirements of health according to the German"KTW-Empfehlungen", the requirements of the growth of microorganismsaccording to the German "DVGW-Arbeitsblatt W270" and the "Attestation deConfirmitè Sanitaire" (ACS) according to French law and is approved accordingto WRAS (UK).The relevant certificates are available.When corrosive water is involved, or water of some other special compositionsmust be investigated in each individual case.These cables can be used indoors, outdoors, in industrial and agricultural plant,but not in explosion-hazard areas.In other respects DIN VDE 0298-300 (HD 516) applies.Uo/U = 450/750 V- Single-phase and three-phase AC operationLine-Earth/ Line-Line 476/825 V- DC operationLine-Earth/ Line-Line 619/1238 V2.5 kV (test duration 15 min.)The values are valid for a multicore cable or three single-core cables in trefoil inpermanent operation with DC or AC with 50 up to 60 Hz at 30°C ambienttemperature, touching surface, three cores loaded.90°C250°C (max. 5 s)when in motion - 50°Cwhen stationary - 50°C60°C (At higher water temperatures, a shortened cable service life is to beexpected.)MechanicalparametersTensile loadMinimum bending radiiUp to 15 N/mm²See Selection table


Technical DataSpecialparametersWater resistance Test according to DIN VDE 0282-16 (HD 22.16)Requirements of health (testaccording to the Germanregulations)Growth of micoorganismsAcceptance in FranceKTW-EmpfehlungenTest according to the German DVGW-Arbeitsblatt W270Test according to the \"Attestation de Conformitè Sanitaire\" ACS


Design featuresConductor Copper, finely stranded, Class 5 according to DIN VDE 0295 / HD 383 / IEC 60228InsulationOzone, weather and water-resistant insulation compound, base EPRCore identification Colour of cores according to DIN VDE 0293-308:2003SheathSpecial compound, base EPR, colour blueMarking<strong>HYDROFIRM</strong> (T) <strong>SGFLT</strong>-J 4G25 KTW DVGW W270 ACS


Selection and ordering dataNumber of coresand nominalcross-sectionOrder No.Conductordiameter(guidancevalue)Overalldiameterof cableMin.valueOveralldiameterof cableMax.valueMinimumbendingradii(fixedinstallation)Approx.netweightfor1000 mTensileloadMax.valueMinimumbendingradii(freemovement)CurrentcarryingcapacityShortcircuitcurrent(1 s)mm²mmmmmmmmmmkg/kmNAkA<strong>HYDROFIRM</strong>(T) <strong>SGFLT</strong>-O 3x ... without protective-earth conductor3 x 1,5 5DH1 455-7 1,5 5,2 x11,03 x 2,5 5DH1 456-7 1,9 6,1 x13,23 x 4 5DH1 457-7 2,5 7,0 x15,53 x 6 5DH1 458-7 3,0 7,6 x17,43 x 10 5DH1 460-7 3,9 9,3 x21,53 x 16 5DH1 461-7 5,4 11,2 x26,73 x 25 5DH1 462-7 6,4 13,0 x31,63 x 35 5DH1 463-7 7,7 14,6 x35,53 x 50 5DH1 464-7 9,2 17,0 x42,13 x 70 5DH1 465-7 11,0 19,3 x48,46,2 x13,07,6 x15,59,0 x19,09,8 x21,011,5 x25,013,5 x31,015,5 x35,517,5 x40,520,0 x47,022,0 x52,018 23 114 68 23 0,2122 34 170 113 30 0,3627 38 240 180 41 0,5729 42 320 270 53 0,8634 73 502 450 74 1,4354 85 774 720 99 2,2962 95 1068 1125 131 3,5670 108 1452 1575 162 5,0080 120 1981 2250 202 7,1588 133 2682 3150 250 10,00Technical data, dimension and weights are subject to change.PRYSMIAN Germany Version: 1.1 SL - Date: 2011-03-21<strong>HYDROFIRM</strong>(T) <strong>SGFLT</strong>-J 4x ... with protective-earth conductor4 x 1,5 5DH1 466-7 1,5 5,2 x14,54 x 2,5 5DH1 467-7 1,9 6,1 x17,54 x 4 5DH1 468-7 2,5 7,0 x21,04 x 6 5DH1 470-7 3,0 7,6 x23,54 x 10 5DH1 471-7 3,9 9,3 x29,04 x 16 5DH1 472-7 5,4 11,2 x35,04 x 25 5DH1 473-7 6,4 13,0 x41,54 x 35 5DH1 474-7 7,7 14,6 x48,54 x 50 5DH1 475-7 9,2 17,0 x55,54 x 70 5DH1 476-7 11,0 19,3 x62,06,2 x17,27,6 x20,09,0 x23,59,8 x26,511,5 x32,513,5 x39,015,5 x46,017,5 x53,520,0 x61,022,0 x68,718 23 157 90 23 0,2122 34 224 150 30 0,3627 38 317 240 41 0,5729 42 419 360 53 0,8634 73 672 600 74 1,4354 85 1007 960 99 2,2962 100 1409 1500 131 3,5670 110 1918 2100 162 5,0080 125 2571 3000 202 7,1588 140 3543 4200 250 10,00

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!