13.07.2015 Views

example: Quatronic dialog central control in combination ... - Warema

example: Quatronic dialog central control in combination ... - Warema

example: Quatronic dialog central control in combination ... - Warema

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Group <strong>control</strong> – Channel 1 – southside of the roof230V AC6Compakt 444444M4M4M33Level 01(roof)SensorW<strong>in</strong>d + Light8Channel 1230V ACHelligkeitRichtung12 klxWest12 klxWest12 klxWest12 klxWestChannel 2Channel 3230V ACChannel 4Compakt 6More sensorscan be connected<strong>Quatronic</strong><strong>dialog</strong>Reserve44M44M44M44MM3Group <strong>control</strong> – Channel 3 – southside facade... <strong>example</strong>: <strong>Quatronic</strong> <strong>dialog</strong><strong>central</strong> <strong>control</strong> <strong>in</strong> comb<strong>in</strong>ationwith MSE Compact time logicTypical application:Different textile facade awn<strong>in</strong>gs are to be<strong>control</strong>led separately on three facadesand roof of a conservatory. Awn<strong>in</strong>gs areonly to be extended on the particularfacade where the sun is sh<strong>in</strong><strong>in</strong>g. A timermust allow the awn<strong>in</strong>gs on the differentfacades to run at different times. To saveheat<strong>in</strong>g costs, however, the awn<strong>in</strong>gsshould only be extended if the sun haswarmed up the room <strong>in</strong>terior to a certa<strong>in</strong>temperature. As the awn<strong>in</strong>gs have to besafeguarded aga<strong>in</strong>st ra<strong>in</strong> and storm damage,all awn<strong>in</strong>gs are to be retracted automaticallyas soon as these weather conditionsoccur. To facilitate <strong>central</strong> operation,the awn<strong>in</strong>gs located on the same facadeshould also be <strong>control</strong>lable us<strong>in</strong>g ashared pushbutton. The drives for each ofthe 3 facades and roof of the conservatoryshould also receive a pushbutton as agroup <strong>control</strong> for each unit. As the entireconservatory consists of one homogenousglass/metal construction, it is very difficultto accommodate <strong>control</strong> devices. For thisreason, the number of <strong>control</strong> devicesshould be kept to a m<strong>in</strong>imumImplementation:As a 4-channel <strong>central</strong> <strong>control</strong>, the <strong>Quatronic</strong><strong>dialog</strong> fulfils all known <strong>control</strong> requirements.Different limit values can be set for eachchannel. All necessary limit values havebeen entered <strong>in</strong> the factory for all sunprotection awn<strong>in</strong>gs, but can be altered bythe user. Operation is made particularlysimple by way of straightforward menuprompt<strong>in</strong>g and help texts that are availableif required. Each channel of the <strong>Quatronic</strong><strong>dialog</strong> can evaluate the data of all connectedsensors separately. The radio clock receiverthereby ensures that the time is always exactand renders any change from summer tow<strong>in</strong>ter time superfluous. The <strong>central</strong> <strong>control</strong> isprovided as standard with a comb<strong>in</strong>ed w<strong>in</strong>d/sun/radio clock sensor. The sensor forprecipitation with power supply unit and<strong>in</strong>side temperature sensor make it moreconvenient for the <strong>central</strong> <strong>control</strong> to use furtherweather data accord<strong>in</strong>g to the aboverequirements.Depend<strong>in</strong>g on version, the Compact motor<strong>control</strong> unit allows 2, 4 or 6 motors to bedriven simultaneously. Local operation permotor <strong>control</strong> unit occurs either as a group or<strong>in</strong>dividually. Thus, for <strong>example</strong>, a size 6Compact motor <strong>control</strong> unit allows up to 6motors to be <strong>control</strong>led <strong>in</strong>dividually or <strong>in</strong>several groups (e.g. 2 x 3 motors or 1 x 4 and1 x 2 motors, etc.). The fact that it is possibleto connect several drives to one <strong>control</strong> devicemeans that the entire number of devicesrequired can be kept to a m<strong>in</strong>imum.On request, we shall be pleased to sendyou more detailed draw<strong>in</strong>gs and documentationof the <strong>Quatronic</strong> <strong>dialog</strong> and Compactmotor <strong>control</strong> unit, also <strong>in</strong> connectionwith other <strong>central</strong> <strong>control</strong>s.


230V ACCompakt 44444M44M44M44M44M3Level 00(groundfloor)Group <strong>control</strong> – Channel 2 – westside facade

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!