WinTrac⢠5.X
WinTrac⢠5.X WinTrac⢠5.X
Chapter 9Advanced WinTrac FeaturesGraded-Sensor Calibration1. Select the Calibrate sensors… option under the Tools menu. The sensor calibration windowappears.2. Select the Sensor you wish to calibrate. WinTrac reads the current sensor settings (including sensorgrade) from your DAS.3. Select graded-sensor calibration and choose the required sensor grade (it should be stamped on thesensor).4. Click on the Calibrate… button. WinTrac will calibrate the sensor and inform you when calibration iscomplete.80
Chapter 9Advanced WinTrac FeaturesRestarting your Thermo King DeviceWinTrac software allows you to perform a restart on some data loggers and controllers, namely the DAS,MPD, MPVI, SR-2/SR-3, HMI, i-Box and TTMT. Normally you do not need to restart your unit, so you shouldonly restart your controller when directed to by the appropriate manual.There are three kinds of restarts currently defined in WinTrac:-Warm RestartA Warm restart reboots your controller or data logger. You will not lose any logged data or any unit settings. AWarm restart has the same effect as powering off your TK device and switching it back on again.Cold RestartA Cold restart will reset all settings back to default. Any logged data on your data logger or controller willremain.To perform a Restart on your TK device:-1. Select Restart Device... from the Tools menu.2. Select the type of Restart you want to perform. WinTrac will search for a TK device and ask you toconfirm your actions before restarting the device.WinTrac will confirm that the TK device was restarted.81
- Page 35 and 36: Chapter 4Communicating with your Th
- Page 37 and 38: Chapter 4MPIV, MPV, MPVI SettingsCo
- Page 39 and 40: Chapter 4Communicating with your Th
- Page 41 and 42: Chapter 4Communicating with your Th
- Page 43 and 44: Chapter 4Communicating with your Th
- Page 45 and 46: Chapter 4Communicating with your Th
- Page 47 and 48: Chapter 4Communicating with your Th
- Page 49 and 50: Chapter 4Communicating with your Th
- Page 51 and 52: Chapter 4VPRS SettingsCommunicating
- Page 53 and 54: Chapter 4Communicating with your Th
- Page 55 and 56: Chapter 4Communicating with your Th
- Page 57 and 58: Chapter 4Communicating with your Th
- Page 59 and 60: Chapter 4Communicating with your Th
- Page 61 and 62: Chapter 5Managing your WinTrac Data
- Page 63 and 64: Chapter 5Managing your WinTrac Data
- Page 65 and 66: Chapter 5Managing your WinTrac Data
- Page 67 and 68: Chapter 6Viewing your Data Graphica
- Page 69 and 70: Chapter 6Viewing your Data Graphica
- Page 71 and 72: Chapter 7Viewing your Data in Tabul
- Page 73 and 74: Chapter 7Viewing your Data in Tabul
- Page 75 and 76: Chapter 7Viewing your Data in Tabul
- Page 77 and 78: Chapter 8Personalizing the DisplayT
- Page 79 and 80: Chapter 8Personalizing the DisplayT
- Page 81 and 82: Chapter 9Advanced WinTrac Features6
- Page 83 and 84: Chapter 9Advanced WinTrac FeaturesU
- Page 85: Chapter 9Advanced WinTrac Features6
- Page 89 and 90: Chapter 9Advanced WinTrac FeaturesU
- Page 91 and 92: Chapter 9Advanced WinTrac FeaturesC
- Page 93 and 94: Chapter 10Troubleshooting your WinT
- Page 95 and 96: Chapter 10Troubleshooting your WinT
- Page 97 and 98: Chapter 11License AgreementChapter
Chapter 9Advanced WinTrac FeaturesRestarting your Thermo King DeviceWinTrac software allows you to perform a restart on some data loggers and controllers, namely the DAS,MPD, MPVI, SR-2/SR-3, HMI, i-Box and TTMT. Normally you do not need to restart your unit, so you shouldonly restart your controller when directed to by the appropriate manual.There are three kinds of restarts currently defined in WinTrac:-Warm RestartA Warm restart reboots your controller or data logger. You will not lose any logged data or any unit settings. AWarm restart has the same effect as powering off your TK device and switching it back on again.Cold RestartA Cold restart will reset all settings back to default. Any logged data on your data logger or controller willremain.To perform a Restart on your TK device:-1. Select Restart Device... from the Tools menu.2. Select the type of Restart you want to perform. WinTrac will search for a TK device and ask you toconfirm your actions before restarting the device.WinTrac will confirm that the TK device was restarted.81