WinTrac⢠5.X
WinTrac⢠5.X WinTrac⢠5.X
Chapter 4Communicating with your Thermo King UnitsTruck Standard DisplayTSD DisplayThe SR-2/SR-3 and HMI Settings windows give you access to the operating parameters of the controller andHMI data loggers. You can view/alter the Truck/Trailer ID, Clock, Sensor labels, Logging Interval, and manyother parameters. In addition, you may also send a Text Header or Start-of-Trip [SOT] Header to the device. Afull list of parameters accessible from the Settings window is provided below.ParameterUnit S/NTruck/Trailer IDHMI Date and TimeSR-2/SR-3 Date and TimeText HeaderStart-Of-Trip HeaderSensor AcronymsSensor LoggingSensor ReadingsLogging IntervalSerial NumberSoftware RevisionAlarm Codes & DescriptionsAccessRead/WriteRead/WriteRead/WriteRead OnlyWriteWriteRead OnlyRead/WriteRead OnlyRead/WriteRead OnlyRead OnlyRead Only28
Chapter 4Communicating with your Thermo King UnitsUnit S/NThe ID is a 10 character string, used to identify the Thermo King unit. The ID is normally set to the RegistrationNumber of the Trailer or Container, for easy identification.Truck/Trailer IDThe Unit ID is a 10 character text field, normally used to store the Unit Serial ID number.SR-2/SR-3 & HMI Date and TimeWinTrac allows you to view the current Date and Time of the HMI data logger. It is important that the HMIclock is set to the correct Date and Time since this will affect the validity of the data stored in the logger. Youcan change the Date and Time using WinTrac software, if it is incorrect. The SR-2/SR-3 clock cannot be setas its value is copied from the attached HMI clock.Text HeaderYou can send a Text Header to your SR-2/SR-3 logger using WinTrac software. A Text Header consists of aseries of text fields containing useful information about a particular Trip. Once you send a header, WinTrac willremember your settings and will automatically fill in the fields for you the next time you choose to send a TextHeader to your SR-2/SR-3.Start-of-Trip [SOT] HeaderYou can send a Start-of-Trip Header to your SR-2/SR-3 Loggers using WinTrac software. Simply select theSOT option on the Header Tab, and click on the ‘Send SOT Header’ button.Sensor AcronymThe SR-2/SR-3/SR-3/SR-3 unit stores the sensor acronyms with a maximum length of 5 characters for eachlabel. WinTrac uses these acronyms when displaying sensor information for a particular SR-2/SR-3 dataloggerSensor LoggingThe SR-2/SR-3 data logger allows you to select various logging options for each sensor displayed in theSensor grid. Simply click on the Logging setting to change it.. Click on ‘Update Unit’ in order to send yourchanges to the SR-2/SR-3 data loggerLogging IntervalThe SR-2/SR-3 logs the readings for each probe each Logging Interval. The logging interval may be set to 2mins, 5 mins, 10 mins, 15 mins, 30 mins, 1 hour, 2 hours, or 4 hours.Software RevisionWinTrac displays the software revision of the SR-2/SR-3 unit currently connected to your PC.29
- Page 1 and 2: WinTrac 5.XUser GuideTK 54890-8-MS
- Page 3: Table of ContentsChapter 1 ........
- Page 7 and 8: Chapter 1Welcome to WinTrac Softwar
- Page 9 and 10: Chapter 1Welcome to WinTrac Softwar
- Page 11 and 12: Chapter 2Installing your WinTrac 5
- Page 13 and 14: Chapter 3Personalizing your WinTrac
- Page 15 and 16: Chapter 4Communicating with your Th
- Page 17 and 18: Chapter 4Communicating with your Th
- Page 19 and 20: Chapter 4Communicating with your Th
- Page 21 and 22: Chapter 4Communicating with your Th
- Page 23 and 24: Chapter 4Communicating with your Th
- Page 25 and 26: Chapter 4Communicating with your Th
- Page 27 and 28: Chapter 4Communicating with your Th
- Page 29 and 30: Chapter 4Communicating with your Th
- Page 31 and 32: Chapter 4Communicating with your Th
- Page 33: Chapter 4Communicating with your Th
- Page 37 and 38: Chapter 4MPIV, MPV, MPVI SettingsCo
- Page 39 and 40: Chapter 4Communicating with your Th
- Page 41 and 42: Chapter 4Communicating with your Th
- Page 43 and 44: Chapter 4Communicating with your Th
- Page 45 and 46: Chapter 4Communicating with your Th
- Page 47 and 48: Chapter 4Communicating with your Th
- Page 49 and 50: Chapter 4Communicating with your Th
- Page 51 and 52: Chapter 4VPRS SettingsCommunicating
- Page 53 and 54: Chapter 4Communicating with your Th
- Page 55 and 56: Chapter 4Communicating with your Th
- Page 57 and 58: Chapter 4Communicating with your Th
- Page 59 and 60: Chapter 4Communicating with your Th
- Page 61 and 62: Chapter 5Managing your WinTrac Data
- Page 63 and 64: Chapter 5Managing your WinTrac Data
- Page 65 and 66: Chapter 5Managing your WinTrac Data
- Page 67 and 68: Chapter 6Viewing your Data Graphica
- Page 69 and 70: Chapter 6Viewing your Data Graphica
- Page 71 and 72: Chapter 7Viewing your Data in Tabul
- Page 73 and 74: Chapter 7Viewing your Data in Tabul
- Page 75 and 76: Chapter 7Viewing your Data in Tabul
- Page 77 and 78: Chapter 8Personalizing the DisplayT
- Page 79 and 80: Chapter 8Personalizing the DisplayT
- Page 81 and 82: Chapter 9Advanced WinTrac Features6
- Page 83 and 84: Chapter 9Advanced WinTrac FeaturesU
Chapter 4Communicating with your Thermo King UnitsUnit S/NThe ID is a 10 character string, used to identify the Thermo King unit. The ID is normally set to the RegistrationNumber of the Trailer or Container, for easy identification.Truck/Trailer IDThe Unit ID is a 10 character text field, normally used to store the Unit Serial ID number.SR-2/SR-3 & HMI Date and TimeWinTrac allows you to view the current Date and Time of the HMI data logger. It is important that the HMIclock is set to the correct Date and Time since this will affect the validity of the data stored in the logger. Youcan change the Date and Time using WinTrac software, if it is incorrect. The SR-2/SR-3 clock cannot be setas its value is copied from the attached HMI clock.Text HeaderYou can send a Text Header to your SR-2/SR-3 logger using WinTrac software. A Text Header consists of aseries of text fields containing useful information about a particular Trip. Once you send a header, WinTrac willremember your settings and will automatically fill in the fields for you the next time you choose to send a TextHeader to your SR-2/SR-3.Start-of-Trip [SOT] HeaderYou can send a Start-of-Trip Header to your SR-2/SR-3 Loggers using WinTrac software. Simply select theSOT option on the Header Tab, and click on the ‘Send SOT Header’ button.Sensor AcronymThe SR-2/SR-3/SR-3/SR-3 unit stores the sensor acronyms with a maximum length of 5 characters for eachlabel. WinTrac uses these acronyms when displaying sensor information for a particular SR-2/SR-3 dataloggerSensor LoggingThe SR-2/SR-3 data logger allows you to select various logging options for each sensor displayed in theSensor grid. Simply click on the Logging setting to change it.. Click on ‘Update Unit’ in order to send yourchanges to the SR-2/SR-3 data loggerLogging IntervalThe SR-2/SR-3 logs the readings for each probe each Logging Interval. The logging interval may be set to 2mins, 5 mins, 10 mins, 15 mins, 30 mins, 1 hour, 2 hours, or 4 hours.Software RevisionWinTrac displays the software revision of the SR-2/SR-3 unit currently connected to your PC.29