Chapter 4Communicating with your Thermo King UnitsSome DMS parameters are located on the Advanced DMS Settings window. This window is accessed byclicking on the More… button, located on the Advanced tab of the DMS Settings Window.ParameterLogger IDDMS Date and TimeText HeaderStart-Of-Trip HeaderSensor LabelsSensor AlarmEnable/DisableSensor Alarm ThresholdsLogging IntervalLogging Mode [2/6 Sensor]Display optionsPrint optionsDMS TimersSatellite Port ConfigurationHourmetersSoftware RevisionSensor ReadingsAccessRead/WriteRead/WriteWriteWriteRead/WriteRead/WriteRead/WriteRead/WriteRead/WriteRead/WriteRead/WriteRead/WriteRead/WriteRead/WriteRead OnlyRead OnlyLogger IDThe Logger ID is a 10 character string, used to identify the DMS unit. The Logger ID is normally set to theRegistration Number of the Trailer, for easy identification.DMS Date and TimeWinTrac allows you to view the current Date and Time of the DMS data logger. It is important that the DMSclock is set to the correct Date and Time since this will affect the validity of the data stored in the logger. Youcan change the Date and Time using WinTrac software, if it is incorrect.Text HeaderYou can send a Text Header to your DMS logger using WinTrac software. A Text Header consists of a seriesof text fields containing useful information about a particular Trip. Once you send a header, WinTrac willremember your settings and will automatically fill in the fields for you the next time you choose to send a TextHeader to your DMS.22
Chapter 4Communicating with your Thermo King UnitsStart-of-Trip [SOT] HeaderYou can send a Start-of-Trip Header to your DMS Loggers using WinTrac software. Simply select the SOToption on the Header Tab, and click on the ‘Send SOT Header’ button.Sensor LabelsThe DMS unit stores the sensor labels with the maximum length of 15 characters for each label. WinTrac usesthese labels when displaying sensor information for a particular DMS data logger.Sensor AlarmsEach Sensor on the DMS data logger has an out-of-range alarm associated with it. An out-of-range alarm willbe recorded by the DMS data logger, as well as causing the DMS display to flash. You can enable or disablethis alarm capability. You may also define upper and lower temperature thresholds for the out-of-range alarm.To access the alarm settings for the DMS sensors, Click on the Change Settings… button located on theSensors tab of the DMS properties window.Logging IntervalThe DMS logs the readings for each probe each Logging Interval. The logging interval may be set to 2 mins,5mins, 10 mins, 15 mins, 30 mins, 1 hour, 2 hours, or 4 hours.Logging ModeThe DMS data logger can be set to store the readings of the first two sensors (Return Air and Discharge Air),or all six sensors (including the four spare sensors). The Setpoint sensor input is always logged by the DMSdata logger.Display OptionsYou can choose to enable or disable the DMS display from WinTrac software. You can also choose thetemperature units (either °C or °F) used on your DM S display.Printout OptionsThere are several printout options available on your DMS data logger when using a hand-held printer. You canchoose to enable or disable print completely, as well as enable or disable a chart printout, and exceptionprinting.Timer InformationThe DMS data logger has three timers with user-settable intervals. The three timers are Pull-down out-ofrangetimer, Defrost timeout timer, and Defrost recovery timer. You can set the interval of these timers usingWinTrac software. Timer information is contained on the Advanced DMS Settings window.Satellite PortSome DMS units are equipped with a secondary serial port for communications, often referred to as theSatellite Port. You can configure this satellite port to either DataPac, Qualcomm, or remote.23
- Page 1 and 2: WinTrac 5.XUser GuideTK 54890-8-MS
- Page 3: Table of ContentsChapter 1 ........
- Page 7 and 8: Chapter 1Welcome to WinTrac Softwar
- Page 9 and 10: Chapter 1Welcome to WinTrac Softwar
- Page 11 and 12: Chapter 2Installing your WinTrac 5
- Page 13 and 14: Chapter 3Personalizing your WinTrac
- Page 15 and 16: Chapter 4Communicating with your Th
- Page 17 and 18: Chapter 4Communicating with your Th
- Page 19 and 20: Chapter 4Communicating with your Th
- Page 21 and 22: Chapter 4Communicating with your Th
- Page 23 and 24: Chapter 4Communicating with your Th
- Page 25 and 26: Chapter 4Communicating with your Th
- Page 27: Chapter 4Communicating with your Th
- Page 31 and 32: Chapter 4Communicating with your Th
- Page 33 and 34: Chapter 4Communicating with your Th
- Page 35 and 36: Chapter 4Communicating with your Th
- Page 37 and 38: Chapter 4MPIV, MPV, MPVI SettingsCo
- Page 39 and 40: Chapter 4Communicating with your Th
- Page 41 and 42: Chapter 4Communicating with your Th
- Page 43 and 44: Chapter 4Communicating with your Th
- Page 45 and 46: Chapter 4Communicating with your Th
- Page 47 and 48: Chapter 4Communicating with your Th
- Page 49 and 50: Chapter 4Communicating with your Th
- Page 51 and 52: Chapter 4VPRS SettingsCommunicating
- Page 53 and 54: Chapter 4Communicating with your Th
- Page 55 and 56: Chapter 4Communicating with your Th
- Page 57 and 58: Chapter 4Communicating with your Th
- Page 59 and 60: Chapter 4Communicating with your Th
- Page 61 and 62: Chapter 5Managing your WinTrac Data
- Page 63 and 64: Chapter 5Managing your WinTrac Data
- Page 65 and 66: Chapter 5Managing your WinTrac Data
- Page 67 and 68: Chapter 6Viewing your Data Graphica
- Page 69 and 70: Chapter 6Viewing your Data Graphica
- Page 71 and 72: Chapter 7Viewing your Data in Tabul
- Page 73 and 74: Chapter 7Viewing your Data in Tabul
- Page 75 and 76: Chapter 7Viewing your Data in Tabul
- Page 77 and 78: Chapter 8Personalizing the DisplayT
Chapter 4Communicating with your Thermo King UnitsStart-of-Trip [SOT] HeaderYou can send a Start-of-Trip Header to your DMS Loggers using WinTrac software. Simply select the SOToption on the Header Tab, and click on the ‘Send SOT Header’ button.Sensor LabelsThe DMS unit stores the sensor labels with the maximum length of 15 characters for each label. WinTrac usesthese labels when displaying sensor information for a particular DMS data logger.Sensor AlarmsEach Sensor on the DMS data logger has an out-of-range alarm associated with it. An out-of-range alarm willbe recorded by the DMS data logger, as well as causing the DMS display to flash. You can enable or disablethis alarm capability. You may also define upper and lower temperature thresholds for the out-of-range alarm.To access the alarm settings for the DMS sensors, Click on the Change Settings… button located on theSensors tab of the DMS properties window.Logging IntervalThe DMS logs the readings for each probe each Logging Interval. The logging interval may be set to 2 mins,5mins, 10 mins, 15 mins, 30 mins, 1 hour, 2 hours, or 4 hours.Logging ModeThe DMS data logger can be set to store the readings of the first two sensors (Return Air and Discharge Air),or all six sensors (including the four spare sensors). The Setpoint sensor input is always logged by the DMSdata logger.Display OptionsYou can choose to enable or disable the DMS display from WinTrac software. You can also choose thetemperature units (either °C or °F) used on your DM S display.Printout OptionsThere are several printout options available on your DMS data logger when using a hand-held printer. You canchoose to enable or disable print completely, as well as enable or disable a chart printout, and exceptionprinting.Timer InformationThe DMS data logger has three timers with user-settable intervals. The three timers are Pull-down out-ofrangetimer, Defrost timeout timer, and Defrost recovery timer. You can set the interval of these timers usingWinTrac software. Timer information is contained on the Advanced DMS Settings window.Satellite PortSome DMS units are equipped with a secondary serial port for communications, often referred to as theSatellite Port. You can configure this satellite port to either DataPac, Qualcomm, or remote.23