13.07.2015 Views

EMBSIN 100 I Transducer for AC current - Mbs-ag.com

EMBSIN 100 I Transducer for AC current - Mbs-ag.com

EMBSIN 100 I Transducer for AC current - Mbs-ag.com

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>EMBSIN</strong> <strong>100</strong> I<strong>Transducer</strong> <strong>for</strong> <strong>AC</strong> <strong>current</strong>Self-poweredWith 2 measuring rangesCarrying rail housing MBS/SP1ApplicationThe transducer <strong>EMBSIN</strong> <strong>100</strong> I (Fig. 1) converts a sinusoidal <strong>AC</strong><strong>current</strong> signal into an output signal that can serves several receivinginstruments such as indicators, recorders, alarm units etc.The transducer fulfi ls all the important requirements and regulationsconcerning electrom<strong>ag</strong>netic <strong>com</strong>patibility EMC and Safety (IEC1010 resp. EN 61 010). It was developed and is manufactured andtested in strict accordance with the quality assurance standardISO 9001.Fig. 1. <strong>EMBSIN</strong> <strong>100</strong> I transducer in housing MBS/SP1clipped onto a top-hat rail.Features / Benefits● Measuring input: 2 measuring ranges, 1/5 A or 1.2/6 A● Self-powered / Less wiring expense● Low power consumption / Smaller CT’s can be used● Alternatively as marine version per Lloyd's Register of ShippingLayout and mode of operationThe transducer <strong>com</strong>prises a trans<strong>for</strong>mer W, a rectifi er unit G andan amplifi er V (Fig. 2).The measured variable is isolated from the electronics by thetrans<strong>for</strong>mer, and is rectifi ed and smoothed in the rectifi er unit.The amplifi er amplifi es the resultant signal and converts it into theload-independent DC signal.Table 1: Base versionsThe following transducer versions are available as base versions.It is only necessary to quote the Order No.:Description<strong>Transducer</strong> <strong>for</strong> <strong>AC</strong><strong>current</strong>,nominal frequency50 / 60 Hzin housingMBS/SP1Measuringrange, selectableat terminalsOutputsignalOrder No.0…1 A / 5 A 0… 5 mA 127 6980…1 A / 5 A 0…10 mA 127 7050…1 A / 5 A 0…20 mA 127 7130…1.2 A / 6 A 0… 5 mA 127 7210…1.2 A / 6 A 0…10 mA 127 7390…1.2 A / 6 A 0…20 mA 127 747Please <strong>com</strong>plete the Order Code <strong>100</strong> I-M... . acc. to “Table 2:Specifi cation and ordering in<strong>for</strong>mation” <strong>for</strong> versions with userspecific input ranges and/or variable sensitivity.E135/6 A~1/1.2 A~2W G V–5 –6 +ATechnical dataMeasuring input ENominal frequency:Fig. 2. Block di<strong>ag</strong>ram.Nominal input <strong>current</strong> I N(measuring range end value): Measuring range limit values0…0.5 to 0…7.5 A (only one measuringrange)50 / 60 HzMBS Data sheet <strong>100</strong> I DB – 09-08 1


<strong>EMBSIN</strong> <strong>100</strong> I<strong>Transducer</strong> <strong>for</strong> <strong>AC</strong> <strong>current</strong>Own consumption at nominal frequency 50 Hz:Setting(Special feature):Overload capacity:I AN[mA][VA]1 1.55 1.710 2.020 2.5Admissible alteration of full-scale output,variable sensitivity, adjustablewith potentiometerSetting rangeapprox. 0.9 … 1.1 · I N(approx. ± 10%)<strong>100</strong>%0OutputI N0 Meas. input 0.9 1 1.1MeasuredNumber ofDuration of Interval betweenonetwo successivequantity applicationsapplication applicationsI N1.2 x I N––– continuously –––20 x I N10 1 s <strong>100</strong> sMeasuring output AStandard ranges:Burden volt<strong>ag</strong>e:0 … 1, 0 … 5, 0 … 10 or0 … 20 mA15 V15 VExternal resistance: R extmax. [kΩ] =I AN[mA]I AN= full output valueNot superimposedDC volt<strong>ag</strong>e U A:Current limiter underoverload:Volt<strong>ag</strong>e limit underR ext= ∞:Residual ripple:Response time:0 … 10 VExternal resistance ≥ 200 kΩ≤ 1.7 · I AN≤ 30 V≤ 1% p.p.≤ 300 msAccuracy (acc. to EN 60 688)Reference value:Output end valueBasic accuracy: Class 0.5Reference conditions:Ambient temperature 15 … 30 °CInput 0 … <strong>100</strong>%Frequencyf N± 2 HzOutput burdenCurrent: 0.5 · R extmax.Volt<strong>ag</strong>e: 2 · R extmin.Additional error:Temperature infl uence(– 10 … 55 °C) ± 0.2% / 10 KSafetyProtection class: II (protection isolated, EN 61 010)Housing protection: IP 40, housing(test wire, EN 60 529)IP 20, terminals(test fi nger, EN 60 529)Pollution degree: 2Installation category: IIITest volt<strong>ag</strong>e: 50 Hz, 1 min. acc. to EN 61 010-13700 V, measuring input versusmeasuring output and outer surface490 V, measuring output versus outersurfaceInstallation dataMechanical design:Material of housing:Mounting:Mounting position:Weight:Connecting terminalsConnection elements:Permissible cross sectionof the connection leads:Environmental conditionsHousing MBS/SP1Lexan 940 (polycarbonate),fl ammability class V-0 acc. to UL 94,self-extinguishing, non-dripping,free of halogenFor rail mountingAnyApprox. 0.26 kgScrew-type terminals with indirectwire pressure≤ 4.0 mm 2 single-wire or2 × 2,5 mm 2 fi ne-wireOperating temperature: – 10 to + 55 °CStor<strong>ag</strong>e temperature: – 40 to + 70 °CRelative humidity ofannual mean: ≤ 75%Altitude:2000 m max.Indoor use statement!2 Data sheet <strong>100</strong> I DB – 09-08 MBS


<strong>EMBSIN</strong> <strong>100</strong> I<strong>Transducer</strong> <strong>for</strong> <strong>AC</strong> <strong>current</strong>Table 2: Specification and ordering in<strong>for</strong>mation (see also Table 1: “Base versions”)DescriptionBlockingcodeNo-go withblocking codeArticle No./Feature<strong>EMBSIN</strong> <strong>100</strong> I Order Code <strong>100</strong> I - xxxx x <strong>100</strong> I -Features, Selection1. Mechanical designHousing MBS/SP1 <strong>for</strong> rail mountingM2. Measuring range0 … 1 / 5 A 10 … 1.2 / 6 A 2Non-standard 0 … 0.5 to 0 … 7.5 A[A](<strong>for</strong> one measuring range only)9Lines 1 and 2: Lower or higher range depending on connection3. Output signal0 … 5 mA, R ext≤ 3 kΩ 10 … 10 mA, R ext≤ 1.5 kΩ 20 … 20 mA, R ext≤ 750 Ω 30 … 1 mA, R ext≤ 15 kΩ 40 … 10 V, R ext≥ 200 kΩ ANon-standard 0 … 1 to 0 … < 10 [V] Z4. Measuring range adjustableMeasuring range end value permanently set 0Measuring range can be adjusted approx. ± 10% 15. Test recordsWithout test records 0Test records in GermanDTest records in EnglishEElectrical connectionsConnectionConnecting terminalsMeasuring input E1 and 2 or 1 and 3acc. to version, see type labelMeasuring output A 5 – and 6+Standard accessories1 Operating Instructions in three langu<strong>ag</strong>es: German, French,EnglishDimensional drawing112114Fig. 3. <strong>EMBSIN</strong> <strong>100</strong> I in housing MBS/SP1 clipped onto a top-hat rail(35 ×15 mm or 35×7.5 mm, acc. to EN 50 022).3570MBS AGEisbachstraße 5174429 Sulzbach-LaufenSulzbach MesswandlerPhone: +49 79 76- 98 51-0Fax: +49 79 76- 98 51-90Email: mbs@mbs-stromwandler.deSubject to change without notice • Edition 09.08 • Data sheet <strong>100</strong> I DB

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!