144 Centrifuge overviewMeet the next generation in centrifugationWe introduced our very first centrifuge in 1964 as an integralpart of the <strong>Eppendorf</strong> ® Microliter System, and revolutionized <strong>life</strong>science research practices worldwide. To this day, the <strong>Eppendorf</strong>name remains synonymous <strong>with</strong> innovative design, technologyand performance that stand the test of time.Our new line of centrifuges was designed <strong>with</strong> you and yourapplications in mind to deliver a product performance thatgoes far beyond speed and capacity to benefit you and yourapplications. <strong>In</strong> addition to the speed, capacity and versatilityyou need for all your applications, our new <strong>Eppendorf</strong>microcentrifuges offer unparalleled ergonomic operation(e.g., lowest noise levels, soft-<strong>touch</strong> one-finger lid closures,low profiles) and superior temperature management formaximum sample protection and energy-savings (e.g.,dynamic compressor control, ECO shut-off). All refrigeratedmodels have the compressor at the back for a space-savingsmall footprint and a low profile for easy operation. With theiroutstanding quality <strong>Eppendorf</strong> centrifuges are the costefficient solution for your lab.Reward yourself <strong>with</strong> an <strong>Eppendorf</strong> centrifuge.epGreen features3 | <strong>In</strong>fo | CentrifugationAs a commitment to the environment and future generationswe constantly look for ways to improve the eco-friendliness ofour products. This already started many years ago when weswitched all our refrigerated models to CFC-free refrigerants<strong>with</strong> zero ozone depletion potential. All our centrifuges are nowdesigned to deliver the performance you need for successfulexperiments while minimizing the environmental impact. Theyfollow our epGreen philosophy by providing several eco-friendlyproduct features:‡‡Up to 25% energy savings during operation comparedto predecessor models‡‡Use of brushless induction motors to provide maintenancefreeoperation and eliminate carbon-particle emission‡‡Optimized sound design for low noise emission‡‡Low-weight fixed-angle rotor design for less powerconsumption during spinning and improved cooling efficiency‡‡Rotors are made of 100% recyclable aluminum‡‡100% recyclable packaging materialOur refrigerated models are equipped <strong>with</strong> the latestinnovations in cooling technology, to significantly reduceenergy consumption:‡‡Use of CFC-free refrigerant <strong>with</strong> no ozone depletion potential‡‡Patented, dynamic compressor control technology (DCC)provides superior temperature accuracy for maximumsample protection. The DCC technology also reducesvibration for smooth spins and minimal re-mixing of samples.‡‡Optimized insulation improves temperature efficiency‡‡Up to 49% energy savings due to unique ECO shut-off thatdeactivates compressor after 8 hours of nonuse—standardfor all refrigerated <strong>Eppendorf</strong> centrifuges.‡‡60% less energy consumption <strong>with</strong> Model 5424 R duringprecooling to 4 °C due to a unique, compressor technologythat allows for fast, 8 min precooling of centrifuge and rotor‡‡Up to 80% lower energy consumption <strong>with</strong> unique FastTemp profunction (Model 5430 R). FastTemp pro allows for automatedpre-cooling based on pre-programmable time and date.Turn off the compressor and let FastTemp pro take care ofpre-cooling in the morning.Energy use in %10090807060504030201005418 R 5424 R 5430 R100contin.coolingYou save:47%ECOshut-off+ FastTemp100contin.coolingYou save:40%ECOshut-off+ FastTemp100contin.coolingYou save:37%ECOshut-off+ FastTempYou save:79%FastTemp proLight green: energy consumption <strong>with</strong> ECO shut-offDark green: energy consumption of FastTemp/FastTemp pro pre-coolingEnergy-savings <strong>with</strong> refrigerated <strong>Eppendorf</strong> centrifuges.ECO shut-off function saves up to 47% energy by deactivating thecompressor after 8 hours of nonuse. Values listed for Models 5418 R,5424 R and 5430 R refer to energy-savings in percent (after FastTempcooling to 4 °C) compared to continuous overnight cooling for 17 h.Achieve up to 79% energy-savings <strong>with</strong> unique FastTemp pro functionof Model 5430 R. Turn off the compressor overnight and allow FastTemp proto automatically pre-cool the centrifuge at any given date and time.Order from your laboratory supply dealer.Product appearance, specifications, and/or prices are subject to change <strong>with</strong>out notice.


146 MicrocentrifugesMicrocentrifuges 5418 and 5418 RProduct features3 | <strong>In</strong>struments | CentrifugationTechnical specificationsDescription 5418 5418 Rg-force (rcf)100–16,873 x gSpeed100–14,000 rpmMaximum capacity18 x 1.5/2.0 mLNumber of rotors 1Acceleration time 113 sBraking time 113 sTimer30 s to 9:59 h, <strong>with</strong> continuous modeNoise level < 51 dB(A) < 57 dB(A)Temperature control – 0 °C–40 °CPower supply120 V/50–60 Hz230 V/50–60 HzPower requirement max. 170 W max. 320 WDimensions(W x D x H)8.2 x 11.8 x 8.3 in/21 x 30 x 21 cm1Acceleration/braking time to/from max. speed <strong>with</strong> rotor FA-45-18-1111.7 x 18.2 x 9.8 in/30 x 46 x 25 cmHeight <strong>with</strong> lid open 16.7 in/43 cm 20 in/51 cmWeight <strong>with</strong>out rotor 17 lb/7.7 kg 48.5 lb/22 kg‡‡Capacity: 18 x 1.5/2.0 mL‡‡Speed up to 16,873 x g (14,000 rpm)‡‡Compact footprint to fit on crowded lab benches‡‡OptiBowl ® design allows for whisper quiet operation<strong>with</strong>out rotor lid to reduce handling time and benefityour work environment‡‡Soft-<strong>touch</strong> one-finger closure centrifuge lid forergonomic operation‡‡Lid opens automatically at the end of the run to preventsample warming and to allow easy access to samples(5418 only)‡‡QuickLock rotor lid closure for fast and reliable lid locking‡‡Rotor comes standard <strong>with</strong> an aerosol-tight lid for safeuse <strong>with</strong> hazardous materials‡‡Large digital display and rpm/rcf conversion key foraccurate and reproducible parameter settings‡‡Rotary knob control panel for fast parameter selection‡‡2-year warrantyRefrigerated Model 5418 R also features:‡‡Temperature range from 0 °C to 40 °C‡‡Patented compressor technology minimizes vibrationand improves temperature accuracy‡‡Maintains constant 4 °C at maximum speed‡‡FastTemp function for fast pre-cooling and maximumtemperature accuracy inside the rotor‡‡ECO shut-off engages after 8 hours of nonuse toreduce energy consumption and extends compressor<strong>life</strong> (can be deactivated). Saves you up to 47%energy overnight.‡‡Built-in condensation drain to eliminate wateraccumulation and prevent corrosionDescriptionCentrifuges 5418 and 5418 R <strong>with</strong> their 18-place capacity rotorsare specifically designed for low to medium capacity in 1.5/2 mLtubes and Microtainers ® . Their speed of up to 16,873 x g allowsfor standard molecular biology and clinical applications.See page 144 for information on epGreen features.Order from your laboratory supply dealer.Product appearance, specifications, and/or prices are subject to change <strong>with</strong>out notice.


Microcentrifuge rotors147Rotor for Microcentrifuges 5418 and 5418 RQuickLock lid for ergonomic operationRotor <strong>with</strong> unique QuickLock lid—fast andsecure lid locking <strong>with</strong> only 1/4 of a turn. Therotor provides an aerosol-tight containment forsafe centrifugation of hazardous samples suchas viruses, pathogen bacteria, blood samplesor radioactive probes. Rotor comes standard<strong>with</strong> Centrifuges 5418 and 5418 R.Adapter for BD Microtainer ®and 0.5 mL microcentrifuge tubesAdapter for 0.5 mL microcentrifuge or BDMicrotainer ® tubes. Adapter can be usedin any <strong>Eppendorf</strong> ® rotor for 1.5/2 mL tubes.Adapter for 0.2 mL PCR tubesIdeal to spin down PCR tubes afterreaction setup. Adapter fits in any<strong>Eppendorf</strong> 1.5/2.0 mL rotor.3 | <strong>In</strong>struments | CentrifugationOrdering informationDescription Catalog No. List USDCentrifuge 5418, <strong>with</strong> 18 x 1.5/2.0 mL aerosol-tight QuickLock rotor (FA-45-18-11)120 V 022620304 $2,075.00230 V 022620321 2,075.001-year Extended Warranty 901510562 250.00Centrifuge 5418 R (refrigerated), <strong>with</strong> 18 x 1.5/2.0 mL aerosol-tight QuickLock rotor (FA-45-18-11)120 V 5401000137 5,800.00230 V 5401000013 5,800.001-year Extended Warranty 901510661 700.00Rotors and accessoriesRotor 18 x 1.5/2.0 mL <strong>with</strong> aerosol-tight QuickLock lid (FA-45-18-11) 022652061 675.00Rotor lid, for FA-45-18-11, aerosol-tight 022652087 229.00Spare seals, for rotor lid FA-45-18-11, set of 5 022652109 129.00Adapter, for 0.2 mL PCR tubes (for 1.5/2 mL rotors), set of 6 022636260 31.00Adapter, for 0.4 mL tubes (for 1.5/2 mL rotors), set of 6 022636243 31.00Adapter, for 0.5 mL tubes and BD Microtainer tubes (for 1.5/2 mL rotors), set of 6 022636227 31.00* Aerosol-tightness of lid tested by the Centre for Applied Microbiology & Research, Porton Down, CAMR,Great Britain.<strong>In</strong> the U.S.: <strong>Eppendorf</strong> North America 800-645-3050 · <strong>In</strong> Canada: <strong>Eppendorf</strong> Canada Ltd. 800-263-8715E-mail: info@eppendorf.com · www.eppendorf.com


Microcentrifuge rotors149Rotors for Microcentrifuges 5424 and 5424 RAerosol-tight rotor for24 x 1.5/2 mL tubesprovides speed up to21,130 x g (15,000 rpm).(FA-45-24-11;Cat. No. 022653008)Aerosol-tight rotorfor 24 x 1.5/2 mL tubes<strong>with</strong> PTFE-coating forhigh chemical resistance.Provides speed up to21,130 x g (15,000 rpm).(FA-45-24-11-Special;Cat. No. 022653041)Ordering information4 x PCR-strip rotorfor centrifugation up to18,615 x g (15,000 rpm).(F-45-32-5-PCR;Cat. No. 022653121)Kit rotor for 18 x spin columnsand 1.5/2.0 mL tubes for speedup to 18,111 x g (15,000 rpm).This unique rotor offers a solutionfor a common problem whenworking <strong>with</strong> MiniPrep spin columnkits: open tube lids that shear off during the elution step.This problem traditionally occurs because standard rotorsdo not provide enough support for open tube lids duringcentrifugation. The <strong>Eppendorf</strong> ® Kit rotor is designed <strong>with</strong>an extended rim that serves as a rest for tube caps duringcentrifugation and protects them from shearing off.(F-45-18-11-Kit; Cat. No. 022653083)3 | <strong>In</strong>struments | CentrifugationDescription Catalog No. List USDMicrocentrifuge 5424 Knob KeypadWith 24 x 1.5/2.0 mL aerosol-tight rotor (FA-45-24-11), 120 V 022620401 022620444 $2,730.00With 24 x 1.5/2.0 mL aerosol-tight rotor (FA-45-24-11), 230 V 022620428 022620461 2,730.00Without rotor, 120 V 022620487 022620498 2,440.00Without rotor, 230 V 022620436 022620452 2,440.001-year Extended Warranty 901510563 295.00Microcentrifuge 5424 R (refrigerated) Knob KeypadWith 24 x 1.5/2.0 mL aerosol-tight rotor (FA-45-24-11), 120 V 5404000537 5404000138 6,500.00With 24 x 1.5/2.0 mL aerosol-tight rotor (FA-45-24-11), 230 V 5404000413 5404000014 6,500.00Without rotor, 120 V 5404000731 5404000332 5,720.00Without rotor, 230 V 5404000618 5404000219 5,720.001-year Extended Warranty 901510649 690.00Rotors and accessoriesCatalog No.24 x 1.5/2.0 mL rotor <strong>with</strong> aerosol-tight lid (FA-45-24-11) 022653008 825.00Rotor lid, for FA-45-24-11, aerosol-tight 022653024 229.0024 x 1.5/2.0 mL rotor <strong>with</strong> aerosol-tight lid, PTFE-coated (FA-45-24-11-Special) 022653041 965.00Rotor lid, for FA-45-24-11-Special, aerosol-tight 022653067 254.0018 x 1.5/2.0 mL spin column kit rotor, including lid (F-45-18-11-Kit) 022653083 675.00Rotor lid, for F-45-18-11-Kit 022653105 185.004 x PCR-strip rotor, including lid (F-45-32-5-PCR) 022653121 675.00Rotor lid, for F-45-32-5-PCR 022653148 185.00Adapter, for 0.2 mL PCR tubes (for 1.5/2 mL rotors), set of 6 022636260 31.00Adapter, for 0.4 mL tubes (for 1.5/2 mL rotors), set of 6 022636243 31.00Adapter, for 0.5 mL tubes and BD Microtainer ® tubes (for 1.5/2 mL rotors), set of 6 022636227 31.00<strong>In</strong> the U.S.: <strong>Eppendorf</strong> North America 800-645-3050 · <strong>In</strong> Canada: <strong>Eppendorf</strong> Canada Ltd. 800-263-8715E-mail: info@eppendorf.com · www.eppendorf.com


150MicrocentrifugesMicrocentrifuges 5430 and 5430 R3 | <strong>In</strong>struments | CentrifugationTechnical specificationsMicrocentrifuge 5430,keypad version, <strong>with</strong>plate rotor A-2-MTPRefrigerated Microcentrifuge5430 R, rotary knob version,<strong>with</strong> 30 x 1.5/2.0 mL rotorDescription 5430 5430 Rg-force (rcf)10–30,130 x gMaximum speed 100–17,500 rpm (in 10 rpm increments 3 )Maximum capacity30 x 1.5/2 mL, 6 x 50 mL, 2 x MTPNumber of rotors 8Acceleration time 1Braking time 1SOFT brake functionTimer14 s15 sYes30 s to 99:59 h, <strong>with</strong> continuous modeNoise level


Microcentrifuges151Microcentrifuges 5430 and 5430 RProduct features‡‡Capacity: 30 x 1.5/2.0 mL, 6 x 50 mL,12 x Vacutainer ® , 2 x MTP‡‡Speed up to 30,130 x g (17,500 rpm)‡‡Compact footprint (5430/R, W x D: 15 x 25 in/13 x 16 cm)‡‡Centrifuge lid <strong>with</strong> a soft-<strong>touch</strong> closure for ergonomicoperation‡‡Lid opens automatically at the end of the run to preventsample warming and to allow easy access to samples(5430 only, can be deactivated in menu)‡‡Ultra easy operation <strong>with</strong> large LCD display and full-textsoftware menu‡‡Saves up to 50 user-defined programs—5 program keysfor easy access‡‡Easy accessible software features include: SOFT braketo protect delicate samples; adjustable end-of-run alarm;ShortSpin speed limitation; parameter lock; “At set RPM”function for maximum run time reproducibility‡‡Automatic rotor recognition <strong>with</strong> speed limitation androtor imbalance detection for extra safety‡‡Available as a rotary knob version for fast parameterselection, or keypad version for easy cleaning‡‡2-year warrantySee page 144 for information on epGreen features.Refrigerated Model 5430 R also features:‡‡Temperature range from –11 °C to 40 °C‡‡Maintains constant 4 °C at maximum speed‡‡Patented compressor technology minimizes vibrationand improves temperature accuracy‡‡FastTemp program for fast pre-cooling and maximumtemperature accuracy inside the rotor‡‡<strong>In</strong>novative FastTemp pro allows for automated pre-coolingbased on pre-programmable time and date. Turn off thecompressor and let FastTemp pro take care of pre-coolingin the morning. This unique feature saves you up to 80%energy overnight.‡‡ECO shut-off engages after 8 hours of nonuse to reduceenergy consumption and extend compressor <strong>life</strong> (can bedeactivated in menu). Saves 37% energy overnight.‡‡Built-in condensation drain to eliminate wateraccumulation and prevent corrosion3 | <strong>In</strong>struments | CentrifugationOrdering informationModels 5418, 5424 and 5430—Centrifugation redefined.Description Catalog No. List USDMicrocentrifuge 5430 Knob Keypad<strong>with</strong> 30 x 1.5/ 2.0 mL aerosol-tight rotor (FA-45-30-11), 120 V 022620511 022620509 $4,360.00<strong>with</strong> 30 x 1.5/ 2.0 mL aerosol-tight rotor (FA-45-30-11), 230 V N/A as bundle 022620525 4,360.00<strong>with</strong> 24-place mini-prep spin column rotor (FA-45-24-11-Kit), 120 V 022620557 022620541 4,660.00<strong>with</strong> 2-place microplate swing-bucket rotor (A-2-MTP), 120 V 022620572 022620568 5,200.00<strong>with</strong>out rotor, 120 V 022620596 022620584 3,550.00<strong>with</strong>out rotor, 230 V 022620540 022620533 3,550.001-year Extended Warranty, for 5430 901510644 425.00Microcentrifuge 5430 R (Refrigerated) Knob Keypad<strong>with</strong> 30 x 1.5/ 2.0 mL aerosol-tight rotor (FA-45-30-11), 120 V 022620623 022620601 8,600.00<strong>with</strong> 30 x 1.5/ 2.0 mL aerosol-tight rotor (FA-45-30-11), 230 V 022620634 022620612 8,600.00<strong>with</strong> 2-place microplate swing-bucket rotor (A-2-MTP), 120 V 022620656 022620645 9,100.00<strong>with</strong>out rotor, 120 V 022620689 022620667 7,590.00<strong>with</strong>out rotor, 230 V 022620690 022620678 7,590.001-year Extended Warranty, for 5430 R 901510646 925.00<strong>In</strong> the U.S.: <strong>Eppendorf</strong> North America 800-645-3050 · <strong>In</strong> Canada: <strong>Eppendorf</strong> Canada Ltd. 800-263-8715E-mail: info@eppendorf.com · www.eppendorf.com


152Microcentrifuge rotorsRotors for Microcentrifuges 5430 and 5430 RAerosol-tight rotor for 30 x 1.5/2 mL tubes provides speedup to 20,817 x g (14,000 rpm). The rotor is PTFE-coated forhigh chemical resistance and easy cleaning. (FA-45-30-11;Cat. No. 022654047)Basic rotor for 30 x 1.5/2 mL tubes provides speed up to20,817 x g (14,000 rpm). The rotor is PTFE-coated for highchemical resistance and easy cleaning. (F-45-30-11;Cat. No. 022654004)3 | <strong>In</strong>struments | CentrifugationAerosol-tight high-speed rotor for 24 x 1.5/2 mL tubesspins up to 30,130 x g (17,500 rpm). PTFE-coated for highchemical resistance and easy cleaning. (FA-45-24-11-HS;Cat. No. 022654080)Aerosol-tight Kit rotor for 24 x spin columns or 1.5/2 mLtubes. Designed <strong>with</strong> an extra high rim to support open tubelids during centrifugation. Tube lids don’t tear off. Spins atmax. 19,090 x g (13,200 rpm). (FA-45-24-11-Kit;Cat. No. 022654128)2-place swing-bucket rotor for MTP, PCR and deepwellplates up to 29 mm height; speed up to 2,204 x g (4,680 rpm).Windshield design for whisper quiet operation. (A-2-MTP;Cat. No. 022654403)6 x 15/50 mL tube rotor comes <strong>with</strong> adapters for 15 and 50 mLconical tubes. The 50 mL adapter can also handle 50 mL skirtedconical tubes. Additional adapters available (see page 153).Maximum speed 7,814 x g (7,830 rpm). (F-35-6-30;Cat. No. 022654306)18-place rotor for Cryovials ® and HPLC tubes.<strong>In</strong>cludes cryotube adapters. Adapters for 12 x 32 mmHPLC vials available separately. Speed up to 8,900 rpm(F-45-18-17-Cryo; Cat. No. 022654161)Rotor for 8 x 8-tube PCR strips <strong>with</strong> removal adapters thatcan be used as a tube rack for pipetting; maximum speed is11,800 rpm (13,543 x g outer row; 11,987 x g inner row).(F-45-64-5-PCR; Cat. No. 022654209)Order from your laboratory supply dealer.Product appearance, specifications, and/or prices are subject to change <strong>with</strong>out notice.


Microcentrifuge rotors153Rotors for Microcentrifuges 5430 and 5430 RAdapters for 6 x 15/50 mL tube rotor‡‡Rotor <strong>with</strong> 12 positions(6 small and 6 large holesto accommodateappropriate “small”or “large” adapters)‡‡Adapters for 15/50 mLconical tubes areincluded in rotor package‡‡Speed up to 7,830 rpm(7,814 x g)1One tube per adapter, 6 per rotor. Up to 105 mm tube length “small” and “large” adapters for 13, 16, and 17 mm tubes can be combined for a maximum rotor capacity of 12 tubes per run.For all other adapter combinations or longer tube lengths the loading capacity is at least 6 tubes per run. Please perform a manual test to determine the actual loading capacity.2Three sets of 2 are included <strong>with</strong>in 6 x 15/50 mL rotor package3Adapter accommodates skirted 50 mL conical tubesOrdering informationAdapter 1Max TubeDimensionsØ x L (min-max)BottomshapeMax.RCFAdaptersize Catalog No.List USD(set of 2adapters)13 mm round 13 x 75–105 mm Round 7,129 x g Small 022654501 $138.0013 mm round 13 x 90–105 mm Round 7,129 x g Large 022654523 138.0016 mm round 16 x 75–105 mm Round 7,005 x g Small 022654512 138.0016 mm round 16 x 90–105 mm Round 7,005 x g Large 022654524 138.0017 mm round 17 x 90–125 mm Round 7,745 x g Small 022654538 138.0017 mm round 17 x 90–125 mm Round 7,403 x g Large 022654545 138.0015 mL conical 17.5 x 100–125 mm Conical 7,197 x g Small 022654365 2 138.0030 mL round 26 x 92–112 mm Round 7,087 x g Large 022654556 138.0050 mL round 29 x 95–125 mm Round 7,581 x g Large 022654567 138.0050 mL conical 3 29.5 x 100–125 mm Conical 3 7,197 x g Large 022654349 2 138.00Centriprep ® 29.5 x 100–125 mm Flat 7,814 x g Large 022654331 138.00Description Catalog No. List USDRotors and accessoriesRotor 30 x 1.5/2.0 mL <strong>with</strong> aerosol-tight lid, PTFE-coated (FA-45-30-11) 022654047 $1,030.00Rotor lid, for FA-45-30-11, aerosol-tight 022654063 254.00Rotor 30 x 1.5/2.0 mL <strong>with</strong> lid, PTFE-coated (F-45-30-11) 022654004 630.00Rotor lid, for F-45-30-11 022654021 185.00Rotor 24 x 1.5/2.0 mL high-speed <strong>with</strong> aerosol-tight lid, PTFE-coated (FA-45-24-11-HS) 022654080 875.00Rotor lid, for FA-45-24-11-HS, aerosol-tight 022654101 254.00Rotor 24 x 1.5/2.0 mL spin column kit <strong>with</strong> aerosol-tight lid (FA-45-24-11-Kit) 022654128 1,110.00Rotor lid, for FA-45-24-11-Kit, aerosol-tight 022654144 254.00Adapter, for 0.2 mL PCR tubes (for 1.5/2 mL rotors), set of 6 022636260 31.00Adapter, for 0.4 mL tubes (for 1.5/2 mL rotors), set of 6 022636243 31.00Adapter, for 0.5 mL tubes and BD Microtainer ® tubes (for 1.5/2 mL rotors), set of 6 022636227 31.00Rotor 6 x 15/50 mL <strong>with</strong> lid, includes 15/50 mL conical adapters (F-35-6-30) 022654306 1,720.00Rotor lid, for F-35-6-30 022654322 185.00Adapter, for F-35-6-30, set of 2see chart aboveRotor 2 x MTP/microplate <strong>with</strong> lid, includes plate buckets (A-2-MTP) 022654403 1,645.00Rotor lid, for A-2-MTP 022654446 300.00Adapter, for PCR 96-well plates, set of 2 022638947 168.00Adapter, for PCR 384-well plates, set of 2 022638955 168.00Adapter, for plates <strong>with</strong> SBS footprint, set of 2 5825718003 168.00Adapter, for up to 12 glass slides (CombiSlide ® adapter), set of 2 022638963 242.00Rotor 18 x Cryo tubes <strong>with</strong> lid, including cryo-tube adapters 022654161 675.00Rotor lid, for F-45-18-17-Cryo 022654187 185.00Adapter, for 12 x 32 mm HPLC vials, set of 18 5427708006 219.00Adapter, for 1–2 mL cryotubes, set of 6 022639498 80.00Rotor 8 x PCR-strips <strong>with</strong> lid and adapters (F-45-64-5-PCR) 022654209 1,050.00Rotor lid, for F-45-64-5-PCR 022654225 185.00Adapter, for F-45-64-5-PCR, set of 4 022654241 225.003 | <strong>In</strong>struments | Centrifugation<strong>In</strong> the U.S.: <strong>Eppendorf</strong> North America 800-645-3050 · <strong>In</strong> Canada: <strong>Eppendorf</strong> Canada Ltd. 800-263-8715E-mail: info@eppendorf.com · www.eppendorf.com


154 MicrocentrifugesMicrocentrifuge 5415 RProduct features3 | <strong>In</strong>struments | Centrifugation‡‡Capacity: 24 x 1.5/2.0 mL‡‡Speed up to 16,100 x g (13,200 rpm)‡‡Very compact footprint for use on all lab benches‡‡Low profile design for ergonomic loading/unloading ofrotor; allows for complete lid opening under shelves‡‡OptiBowl ® design allows for whisper quiet operation—even <strong>with</strong>out rotor lid—to benefit your work environment‡‡Centrifuge lid <strong>with</strong> a soft-<strong>touch</strong> one-finger closure forergonomic operation‡‡Centrifuge lid <strong>with</strong>out exposed parts or sharp edges‡‡Software features include: End-of-run alarm ON/OFF;ShortSpin speed limitation; parameter lock; “At set RPM”function for maximum run time reproducibility‡‡Rotary knob operation for fast parameter selection‡‡Patented compressor technology minimizes vibration‡‡Temperature range from 0 °C to 40 °C‡‡Maintains constant 4 °C at maximum speed‡‡FastTemp function for fastest pre-cooling andmaximum temperature accuracy inside the rotor‡‡Standby cooling maintains temperature whencentrifuge is not in use‡‡ECO shut-off engages after 8 hours of nonuse toreduce energy consumption and extend compressor <strong>life</strong>‡‡Built-in condensation drain to eliminate wateraccumulation and prevent corrosion‡‡2-year warrantyTechnical specificationsDescriptionMicrocentrifuge 5415 Rg-force (rcf)200–16,100 x g(100 x g increments*)Speed800–13,200 rpm(in 200 rpm increments)Maximum capacity24 x 1.5/2 mLNumber of rotors 3Acceleration time to max. speed ≤13 sBraking time from max. speed ≤11 sTimer30 s to 99 min, <strong>with</strong>continuous modeNoise Level


Microcentrifuge rotors155Rotors for Microcentrifuge 5415 R and discontinued Model 5415 DAerosol-tight rotor for 24 x 1.5/2 mL tubes for safecentrifugation of hazardous samples. Provides speed up to16,100 x g (13,200 rpm). (FA-45-24-11; Cat. No. 022636596)Basic rotor for 24 x 1.5/2 mL tubes provide speed up to16,100 x g (13,200 rpm). Comes <strong>with</strong> basic polypropylenesnap-on lid (F-45-24-11; Cat. No. 022636502)Rotor for 36 x 0.5 mL tubes <strong>with</strong> basic polypropylenesnap-on lid. Speed up to 16,100 x g (13,200 rpm).(F-45-24-11; Cat. No. 022636600)3 | <strong>In</strong>struments | CentrifugationOrdering informationDescription Catalog No. List USDCentrifuge 5415 R (refrigerated)<strong>with</strong> 24 x 1.5/2.0 mL aerosol-tight rotor (FA-45-24-11), 120 V 022621431 $6,575.00<strong>with</strong> 24 x 1.5/2.0 mL rotor (F-45-24-11), 120 V 022621425 6,350.00<strong>with</strong>out rotor, 120 V 022621408 5,810.00<strong>with</strong>out rotor, 230 V 022621459 5,810.001-year Extended Warranty 901510565 700.00Rotors and accessories24 x 1.5/2.0 mL rotor <strong>with</strong> aerosol-tight lid (FA-45-24-11) 022636596 825.00Rotor lid, for FA-45-24-11, aerosol-tight 022636758 229.0024 x 1.5/2.0 mL rotor, including polypropylene snap-on lid (F-45-24-11) 022636502 590.00Rotor lid, for F-45-24-11, snap-on polypropylene 022667289 60.0036 x 0.5 mL rotor, including polypropylene snap-on lid (F-45-36-8) 022636600 915.00Rotor lid, for F-45-36-8, snap-on polypropylene 022667297 60.00Adapter, for 0.2 mL PCR tubes (for 0.5 mL rotors), set of 6 022636286 31.00Adapter, for 0.2 mL PCR tubes (for 1.5/2 mL rotors), set of 6 022636260 31.00Adapter, for 0.4 mL tubes (for 1.5/2 mL rotors), set of 6 022636243 31.00Adapter, for 0.5 mL tubes and BD Microtainer ® tubes (for 1.5/2 mL rotors), set of 6 022636227 31.001Lids are not interchangeable between rotors F-45-24-11 and F-45-36-8.2Aerosol-tightness of lid tested by the Centre for Applied Microbiology & Research, Porton Down, CAMR, Great Britain.<strong>In</strong> the U.S.: <strong>Eppendorf</strong> North America 800-645-3050 · <strong>In</strong> Canada: <strong>Eppendorf</strong> Canada Ltd. 800-263-8715E-mail: info@eppendorf.com · www.eppendorf.com


156 MicrocentrifugesMicrocentrifuge 5417 RProduct features3 | <strong>In</strong>struments | CentrifugationTechnical specificationsDescriptiong-force (rcf)Microcentrifuge 5417 R50–25,000 x gSpeed500–16,400 rpm(in 100 rpm increments)Maximum capacity30 x 1.5/2 mLNumber of rotors 5Acceleration time to max. speed ≤13 sBraking time from max. speed ≤12 sSOFT brake functionYesTimer30 s to 99 min, <strong>with</strong>continuous modeNoise level


Microcentrifuge rotors157Rotors for Microcentrifuge 5417 R and discontinued Model 5417 CAerosol-tight rotor for 30 x 1.5/2 mL tubes for safecentrifugation of hazardous samples. Provides speed up to20,800 x g (14,000 rpm). (FA-45-30-11; Cat. No. 022636057)Rotor for 30 x 1.5/2 mL tubes. Press-on metalrotor lid. Speed up to 20,800 x g (14,000 rpm).(F-45-30-11; Cat. No. 022636006)Aerosol-tight high-speed rotor spins 24 x 1.5/2 mL tubes 1up to 25,000 x g (16,400 rpm). Aerosol-tight lid for safecentrifugation of hazardous samples. (FA-45-24-11;Cat. No. 022636570)Swing-bucket rotor for 8 x 1.5/2 mL tubes forgradient centrifugation or pellet formation at thebottom of the tube. Provides speed up to 10,600 x g(10,000 rpm). (A-8-11; Cat. No. 022636138)3 | <strong>In</strong>struments | Centrifugation6 x PCR-strip rotor <strong>with</strong> centrifugation speedof up to 10,600 x g (10,000 rpm). Safe and easyhandling <strong>with</strong>out additional rotor lid.(F-45-48-PCR; Cat. No. 022636146)Ordering informationDescription Catalog No. List USDRotors and accessories30 x 1.5/2.0 mL rotor <strong>with</strong> aerosol-tight lid (FA-45-30-11) 022636057 $1,060.00Rotor lid, for FA-45-30-11, aerosol-tight 022669133 229.0030 x 1.5/2.0 mL rotor, including lid (F-45-30-11) 022636006 690.00Rotor lid, for F-45-30-11 022376721 185.0024 x 1.5/2.0 mL high-speed rotor <strong>with</strong> aerosol-tight lid 1 (FA-45-24-11) 022636570 915.00Rotor lid, for FA-45-24-11, aerosol-tight 022636782 229.008 x 1.5/2 mL swing-bucket rotor, including swing-buckets and lid (A-8-11) 022636138 1,270.00Swing-buckets 1.5/2mL, for A-8-11 022636141 71.006 x PCR-strip rotor (F-45-48-PCR) 022636146 1,215.00Adapter, for 0.2 mL PCR tubes (for 1.5/2 mL rotors), set of 6 022636260 31.00Adapter, for 0.4 mL tubes (for 1.5/2 mL rotors), set of 6 022636243 31.00Adapter, for 0.5 mL tubes and BD Microtainer ® tubes (for 1.5/2 mL rotors), set of 6 022636227 31.001Can only be used in newer 5417 C (starting serial # 13,000) and 5417 R (starting serial # 7,000) models.<strong>In</strong> the U.S.: <strong>Eppendorf</strong> North America 800-645-3050 · <strong>In</strong> Canada: <strong>Eppendorf</strong> Canada Ltd. 800-263-8715E-mail: info@eppendorf.com · www.eppendorf.com


158 General-purpose centrifugesThe <strong>Eppendorf</strong>® 5702 family of centrifuges3 | <strong>In</strong>struments | CentrifugationGeneral product features‡‡Very compact footprint to fit every lab bench‡‡Whisper quiet operation to benefit your work environment‡‡Low access height for ergonomic access to samples‡‡Rotary knobs for fast parameter selection‡‡Digital display for reproducible parameter selection‡‡SOFT brake function for slow acceleration and braking.Optimized for cell separation by gradient centrifugation(e.g., Ficoll ® separation).‡‡“At set RPM” function starts time counting when selectedspeed is reached for reproducible centrifugation runs‡‡Parameter lock prevents accidental changes‡‡Stainless steel rotor chamber is rust-proof and easyto clean‡‡Electronic imbalance detection for maximum safetyDescriptionThe 5702 family of low-speed, general-purpose centrifuges wasespecially designed to meet the requirements of clinical and cellculture labs. They are compact in design to fit on almost everylab bench, quiet in operation to improve your work environment,and they can be operated <strong>with</strong> 6 different swing-bucket andfixed-angle rotors to accommodate almost any kind of tube.The right model for your application:‡‡Economical Model 5702 for standard applications‡‡Refrigerated Model 5702 R for heat sensitive samples‡‡Heated and refrigerated Model 5702 RH allows centrifugationunder biological conditions to improve cell viability for moreaccurate results in downstream applications (e.g. celltransfection, IVF)Temperature control versions also feature:‡‡Two programming keys to store routine procedures‡‡Separate FastTemp function‡‡Automatic ECO-shut off mode reduces energy consumptionSee page 144 for information on epGreen features.Order from your laboratory supply dealer.Product appearance, specifications, and/or prices are subject to change <strong>with</strong>out notice.


General-purpose centrifuges159Applications for 5702 centrifuge familyUser-friendly control panel featuresCentrifuge 5702 display‡‡Small number of clearly labeled function keys/knobs‡‡Large dials and an easy-to-read back-lit display‡‡Switch between rpm/rcf‡‡Speed can be set from 100 rpm to a max. of4,400 rpm, in increments of 100 rpm‡‡Separate Short Spin button‡‡Timer can be set for up to 99 minutes or continuous‡‡Possible to lock parameter to prevent accidental changesCentrifuges 5702 R and 5702 RH displayTemperature control versions also feature:‡‡Two programming keys to store routine procedures‡‡Separate “FastTemp” function5702 centrifuges are perfectly suited for clinical and cell culture lab applications:Application‡‡Serum or blood plasma purification in bloodcollection tubes <strong>with</strong> or <strong>with</strong>out gel barrier (e.g.BD Vacutainer ® SST or PST tubes)‡‡Mononuclear cell isolation using Ficoll ® gradientcentrifugation‡‡Sperm cell isolation prior to in vitro fertilization (IVF)Recommended accessories4 x 85 mL swing-bucket rotor (A-4-38) <strong>with</strong> roundbuckets and aerosol-tight caps. Depending onapplication, adapters for tubes <strong>with</strong> 13 mm or 16 mmdiameter, and 15 mL or 50 mL conical tubes.Heated Centrifuge 5702 RH allows centrifugation atbiological temperatures to improve cell viability for moreaccurate results in downstream applications (e.g. IVF)‡‡Centrifugation of urine samples in glass tubes 4 x 85 mL swing-bucket rotor (A-4-38) <strong>with</strong> rectangularbuckets and adapters for glass tubes.3 | <strong>In</strong>struments | Centrifugation‡‡Cell culture centrifugation in 15 mL or 50 mL conicaltubes to separate cells from medium‡‡Bacterial or yeast cell separation from suspensionsprior to DNA or protein isolation4 x 85 mL swing-bucket rotor (A-4-38) <strong>with</strong> roundbuckets and adapters for 15 mL and 50 mL conicaltubes.8 x 15 mL swing-bucket rotor <strong>with</strong> inserts for 15 mLconical tubes.‡‡Centrifugation of bacteria, yeast of eukaryotic cellcultures in 15 mL conical tubes or glass tubes‡‡Serum or blood plasma purification in tubes <strong>with</strong> gelbarrier (e.g. BD Vacutainer ® SST or PST tubes)‡‡Ultrafiltration for protein purification or sampleconcentration (e.g. Millipore Centrifree ® )‡‡Knock down of liquid in cryotubes ® prior tocryo conservation30 x 15 mL fixed-angle rotor (F-35-30-17) <strong>with</strong> insertsfor 15 mL conical tubes or rubber mats for glass tubes.Cryotube rotor‡‡Knock down of liquid in 1.5 mL or 2.0 mL<strong>Eppendorf</strong> Tubes ®<strong>Eppendorf</strong> tube rotor<strong>In</strong> the U.S.: <strong>Eppendorf</strong> North America 800-645-3050 · <strong>In</strong> Canada: <strong>Eppendorf</strong> Canada Ltd. 800-263-8715E-mail: info@eppendorf.com · www.eppendorf.com


160General-purpose centrifugesCentrifuge 5702Product featuresGeneral product features of the 5702 family are listedon page 158. Specific features for Model 5702 include:‡‡Whisper quiet operation perfect for constant use‡‡Optimized rotor chamber ventilation minimizessample warming‡‡Lid opens automatically at the end of the run to preventsample warming and allow easy access to samples‡‡2-year warranty3 | <strong>In</strong>struments | CentrifugationDescriptionThe economical centrifuge for the clinical and cell culturelab. With various fixed-angle and swing-bucket rotors andan extensive range of adapters, nearly all types of tubescan be used.Technical specificationsDescription Centrifuge 5702g-force (rcf)100–3,000 x g(100 x g increments)Speed100–4,400 rpm(in 100 rpm increments)Maximum capacity4 x 85 mL or 30 x 15 mLNumber of rotors 6Acceleration time to max. rpm


General-purpose centrifuges161Centrifuges 5702 R and 5702 RHProduct featuresGeneral product features of the 5702 family are listedon page 158. Specific features for Model 5702 R include:DescriptionModels 5702 R and 5702 RH have the compressor at theback to keep the footprint small and the access height low.Our patented compressor technology assures accuratetemperature control, energy efficiency and ease of operation.For active cells, <strong>Eppendorf</strong> ® offers the Centrifuge 5702 RH<strong>with</strong> heating and cooling capabilities. It guarantees maximumtemperature accuracy and can consistently maintain settemperatures above room temperature. Temperature-sensitivecells or cell cultures can be centrifuged at defined temperatures,particularly at 37 °C which increases cell viability to benefit yourdownstream applications.Technical specificationsDescription 5702 R 5702 RHg-force (rcf)100–3,000 x g(100 x g increments)Speed100–4,400 rpm(in 100 rpm increments)Maximum capacity4 x 85 mL or 30 x 15 mLNumber of rotors 6Acceleration time 1


162 General-purpose rotors and accessoriesRotors and accessories for Centrifuges 5702/5702 R/5702 RH3 | <strong>In</strong>struments | Centrifugation4 x 85 mL Swing-bucket Rotor A-4-38‡‡Maximum speed: 3,000 x g (4,400 rpm)‡‡Standard rotor for centrifugation of blood collectiontubes or 15/50 mL conical tubes‡‡Rotor can be operated <strong>with</strong> round or rectangular buckets– Round buckets for tubes 1.5 mL to 85/100 mL,aerosol-tight caps 1 for safe centrifugation(of hazardous samples optionally available)– Rectangular buckets for glass tubes from5 mL to 25 mL‡‡Broad variety of adapters available to fit all typesof blood collection tubes and cell culture tubes8 x 15 mL Swing-bucket Rotor A-8-17‡‡Maximum speed: 2,800 x g (4,400 rpm)‡‡Economical rotor for centrifugation of 15 mL conicaltubes or 15 mL glass tubes‡‡Form insert for 15 mL conical tubes and rubber matinserts for centrifugation of glass tubes optionallyavailableOrdering informationRotor models and accessories Max. rcf (x g)Max. rotationalspeed (rpm) Catalog No. List USD4 x 85 mL Swing-bucket Rotor A-4-38With 4 x 85 mL round buckets 3,000 4,400 022639048 $725.00Round buckets, 85 mL, set of 4 022639081 660.00Aerosol-tight lids, for 85 mL round buckets, set of 2 022639293 107.00Without buckets 3,000 4,400 022639064 485.00Rectangular buckets 2 , 90 mL, set of 4 022639307 510.00Rubber mats, replacements12.5 mm, for adapter 022639102 and 022639242, set of 20 022666941 46.0016 mm, for adapter 022639269, set of 20 022666967 46.0017 mm, for adapter 022639129, set of 16 022666959 46.008 x 15 mL Swing-bucket Rotor A-8-178 x 15 mL (<strong>with</strong>out adapters or rubber mats) 3,000 4,400 022639501 290.00Form inserts, for 15 mL conical tubes, set of 8 022639528 126.00Rubber mats, 17 mm, for 15 mL round bottomor glass tubes, set of 8022639510 33.001Tested by the Centre for Applied Microbiology & Research (CAMR), Porton Down, Great Britain.2Not for use <strong>with</strong> aerosol-tight lids.Order from your laboratory supply dealer.Product appearance, specifications, and/or prices are subject to change <strong>with</strong>out notice.


General-purpose rotors and accessories163Rotors and accessories for Centrifuges 5702/5702 R/5702 RH30 x 15 mL Fixed-angle Rotor F-35-30-1724-place Fixed-angle Rotor F-45-24-11‡‡Maximum speed: 2,750 x g (4,400 rpm)‡‡High-capacity fixed-angle rotor for 20 x 15 mL conicaltubes or 30 x 15 mL glass tubes‡‡Form inserts for 15 mL conical tubes and rubber matsfor use <strong>with</strong> glass tubes are included in delivery‡‡Steel sleeves have an inner diameter of 18 mm and adepth of 92 mm‡‡Maximum rcf: 1,770 x g (4,400 rpm)‡‡Low-noise centrifugation <strong>with</strong>out rotor lid‡‡Centrifugation of 1.5 mL and 2 mL <strong>Eppendorf</strong> Tubes ®‡‡Adapter for:– 0.2 mL PCR tubes (022636260)– 0.4 mL centrifuge tubes (022636243)– 0.5 mL micro test tubes (022636227)– 0.6 mL Microtainer ® tubes (022636227)‡‡Rotor and adapter are autoclavable (121 °C, 20 min)18-place Fixed-angle Rotor F-45-18-17-Cryo‡‡Maximum rcf: 1,840 x g (4,400 rpm)‡‡Low-noise centrifugation <strong>with</strong>out rotor lid‡‡Centrifugation of 1–2 mL cryotubes ® (max. Ø 13 mm,use <strong>with</strong> adapter) and screw-cap centrifugation tubes(max. Ø 17 mm, adapter not needed)‡‡Adapters for 12 x 32 mm HPLC vials available‡‡Rotor and adapter are autoclavable (121 °C, 20 min)3 | <strong>In</strong>struments | CentrifugationOrdering informationRotor models and accessories Max. rcf (x g)Max. rotationalspeed (rpm) Catalog No. List USDFixed-angle Rotor F-35-30-17<strong>In</strong>cludes 30 steel sleeves for 15 mL tubes, <strong>with</strong> 20 form inserts 2,750 4,400 022639404 $645.00for 15 mL conical tubes and 30 rubber mats<strong>In</strong>cludes 10 steel sleeves for 15 mL tubes, <strong>with</strong> 10 form inserts 2,750 4,400 022639421 470.00for 15 mL conical tubes and 10 rubber matsSteel sleeves for rotor F-35-30-17, set of 10 022639439 248.00Form inserts, for 15 mL conical tubes, set of 10 022639447 158.00Rubber mats, 17 mm, for 15 mL round bottom tubes, set of 10 022639455 40.00Fixed-angle Rotor F-45-24-11, for 24 x 1.5/2 mL tubes 1,770 4,400 022639471 510.00Fixed-angle Rotor F-45-18-17-Cryo, <strong>with</strong>out adapters 1,840 4,400 022639480 590.00Adapter, for 1–2 mL cryotubes, set of 6 022639498 80.00Adapter, for 12 x 32 mm HPLC vials, set of 18 5427708006 219.00<strong>In</strong> the U.S.: <strong>Eppendorf</strong> North America 800-645-3050 · <strong>In</strong> Canada: <strong>Eppendorf</strong> Canada Ltd. 800-263-8715E-mail: info@eppendorf.com · www.eppendorf.com


164General-purpose rotors and accessoriesRotors and accessories for Centrifuges 5702/5702 R/5702 RH&Tube typeVolumes (mL) 1.5–2.0 1.1–1.4Swing-bucket rotor A-4-38including 4 round buckets 1022639048$725.00Adapter forround buckets3 | <strong>In</strong>struments | CentrifugationAerosol-tight lid Round bucket 1retrofit kitSet of 24 buckets of85 mL capacity022639293 022639081$107.00 $660.00Maximum tube length for all43 100positions (mm) 2Maximum tube length for use43 100<strong>with</strong> aerosol-tight lid (mm) 2Number of tubes per adapter/rotor 4/16 5/20Adapter bore (Ø mm) 11 8.5Maximum rcf (g-force) 2,900 2,850Centrifugation radius (mm) 134 132Bottom shape round flatCatalog No. 022639277 022639285List USD (set of 2 adapters) $295.00 $295.00Tube typeSwing-bucket RotorA-4-38<strong>with</strong>out buckets1 Swing-bucket rotors are delivered <strong>with</strong> buckets of one weight class. Adapters and tubes,which together do not exceed a maximum weight of 0.418 lb/0.19 kg, can be put in one round bucket.Rectangular bucket sets are delivered <strong>with</strong> buckets of one weight class. Adapters and tubes,which together do not exceed a maximum of 0.528 lb/0.24 kg, can be put in one rectangular bucket.The following applies to rotors <strong>with</strong> round buckets, as well as to rotors <strong>with</strong> rectangular buckets:The total weight of a loaded bucket (including adapter and filled tubes) may not exceed0.836 lb/0.38 kg. The weight given on the rotor applies to buckets (including their load).2If the maximum tube length is exceeded, the loading capacity of the adapter may be reduced.Please perform a manual swing-out test before starting the centrifuge run to make sure thetubes don’t hit the rotor yoke.3Aerosol-tight centrifugation not possible <strong>with</strong> this adapter.4Nominal tube volume as published by tube manufacturers.5Replacement rubber mats available as accessories. See page 162.6Without rubber mat. Rubber mat available as accessories. See page 162.Rectangular bucket 14 buckets of90 mL capacity022639064 022639307$485.00 $510.00Volume (mL) 5–7 9Adapter forrectangular bucketsMaximum tube length (mm) 2 100 100Number of tubes per adapter/rotor 10/40 8/32Adapter bore (Ø mm) 13 14.5Maximum rcf (g-force) 2,750 2,750Centrifugation radius (mm) 127 127Bottom shape incl. rubber matflat rubber mat flat rubber matCatalog No. 022639323 022639340List USD (set of 2 adapters) $149.00 $149.00Order from your laboratory supply dealer.Product appearance, specifications, and/or prices are subject to change <strong>with</strong>out notice.


General-purpose rotors and accessories165Rotors and accessories for Centrifuges 5702/5702 R/5702 RH2–7 2.6–7 4–10 9–15 15 mLconical15 mLconical25 50 mLconical85–100 43105 105 105 105 121 121 100 115 1063105 105 105 105 121 - 100 115 1065/20 4/16 4/16 4/16 1/4 2/8 1/4 1/4 1/412.5 13.5 16 17.5 17.2 17.2 25 30 382,850 2,850 2,850 2,800 3,000 3,000 2,900 2,900 2,900132 132 132 130 137 137 135 135 135flat <strong>with</strong>rubber mat 5flat <strong>with</strong>rubber mat 5flat <strong>with</strong> round 6 conical conical round conical roundrubber mat 5022639102 022639242 022639269 022639129 022639188 022639200 022639145 022639226 022639161$295.00 $295.00 $295.00 $295.00 $163.00 $295.00 $163.00 $163.00 $163.003 | <strong>In</strong>struments | Centrifugation15 20 25100 100 1006/24 4/16 2/817.5 22 252,750 2,750 2,750127 127 127flat rubber mat flat rubber mat flat rubber mat022639366 022639382 022639391$149.00 $149.00 $149.00Fixed-angle Rotor F-45-24-11<strong>with</strong>out lid022639471$510.00Fixed-angle Rotor F-45-18-17-Cryo<strong>with</strong>out lid022639480$590.00Fixed-angle Rotor F-35-30-17<strong>with</strong> 30 steel sleeves022639404$645.00Swing-bucket Rotor A-8-17022639501$290.00<strong>In</strong> the U.S.: <strong>Eppendorf</strong> North America 800-645-3050 · <strong>In</strong> Canada: <strong>Eppendorf</strong> Canada Ltd. 800-263-8715E-mail: info@eppendorf.com · www.eppendorf.com


166 Multipurpose benchtop centrifugesCentrifuges 5804/5804 R and 5810/5810 RDescription<strong>Eppendorf</strong> ® centrifuges 5804/R and 5810/R <strong>with</strong> theirrenowned quality and reliability offer you the most costefficient solutions for your medium to high-throughputapplications—now and in the future.Whether your applications require spinning many tubes ata time or centrifugation of larger volume vessels at highspeed,these multipurpose centrifuges <strong>with</strong> their varietyof rotors and adapters cover virtually any application intubes, bottles, flasks and microplates. They are literallythree centrifuges in one: a high-capacity centrifuge for cellculture and clinical applications; a high-speed centrifugefor separating cell lysates; and a microcentrifuge for nucleicacid purification.3 | <strong>In</strong>struments | CentrifugationMultipurpose centrifuges 5804 and 5804 RThese compact models are ideal for applications in deepwellplates or for molecular applications in large volume tubes upto 100 mL (max. 15,500 x g). The optional swing-bucket rotorfor tubes up to 100 mL (max. 4,500 x g) adds flexibility andmakes Models 5804 and 5804 R 1 winners for all low tomedium throughput laboratories.Multipurpose centrifuges 5810 and 5810 RThese centrifuges are real workhorses for your mid to highthroughputlaboratory. Still equipped <strong>with</strong> a space-savingsmall footprint they provide you significantly higher capacityfor up to 4 x 500 mL bottles, 28 x 50 mL conical tubes or16 x microplates—capacity you would normally find in muchbigger centrifuges only.Models 5810 and 5810 R 1 also accommodate aerosol-tightrotors for plates (3,486 x g) and large volume tubes (up to20,130 x g) for BSL3 level applications <strong>with</strong> hazardous samples.1U.S. Pat. 5,496,254Order from your laboratory supply dealer.Product appearance, specifications, and/or prices are subject to change <strong>with</strong>out notice.


Multipurpose benchtop centrifuges167Centrifuges 5804/5804 R and 5810/5810 RProduct featuresOutstanding versatility for all your applications‡‡Broad rotor and adapter selection to spin all commonlyused tubes, bottles, flasks and plates‡‡High centrifugation speed up to 20,800 x g (14,000 rpm)for molecular applications in tubes from 0.2 to 100 mL‡‡Aerosol-tight rotors and covers for all centrifugeapplications involving hazardous materials (pathogenicbacteria, viruses, blood samples or radioactive material)The benchmark for ergonomic operation‡‡Low sound level to benefit your work environment‡‡Low profile design for ergonomic loading/unloadingof rotor‡‡Centrifuge lid <strong>with</strong> soft-<strong>touch</strong> lid closure and lowopening height for stress-free lid locking‡‡Advanced rotor design minimizes fixed-angle rotorweight for easy lifting and carryingCentrifuge performance you can count on‡‡Outstanding software control guarantees high accuracyof time (±2 s in 5 min), speed (1%) and temperature(±2 °C at 6 °C) for maximum run reproducibility 1‡‡Optional “At Set RPM” mode starts timer when setspeed is reached for maximum run-to-run reproducibilityindependent of rotor load or acceleration speed setting‡‡Possibility for adapter-specific rotor radius adjustment toguarantee maximum RCF accuracyRefrigerated version also featuresUnmatched temperature management for maximumsample protection and energy efficiency(Models 5804 R and 5810 R)‡‡Temperature range from –9 °C to 40 °C‡‡Maintains constant 4 °C, even at maximum speed(6 x 100 mL rotor maintains 9 °C at max. speed;230 V versions)‡‡FastTemp function for fastest pre-cooling (15 min)and maximum temperature accuracy inside the rotor 1‡‡Standby cooling function holds temperature whencentrifuge is not in use‡‡ECO shut-off engages after 8 hours of nonuse to reduceenergy consumption and extend compressor <strong>life</strong>‡‡Built-in condensation drain to eliminate wateraccumulation and prevent corrosion‡‡Patented compressor technology (DCC) for optimizedcooling performance, extended compressor <strong>life</strong> andreduced energy consumption‡‡20 amp version provides improved coolingperformance for operation in very warm climatesor for long centrifugation runs1Please see Certificate of Quality for further details.3 | <strong>In</strong>struments | CentrifugationDesigned to fit in every lab‡‡Compact footprint saves valuable bench space‡‡Low lid opening height and opening angle for useunder shelves‡‡Short depth and low weight for a multipurpose centrifugeallows placement on standard laboratory benches‡‡120 V power supply for use on standard outlets providesmaximum placement flexibility‡‡Compliant to international safety standards—no needto bolt the unit to the table‡‡Automatic rotor recognition and imbalance detectionfor maximum operational rotor identification‡‡2-year warrantyLow noise emissions, energy-saving patentedcompressor technology (DCC) and ECO shut-off;for information on epGreen products, see page 376.<strong>In</strong> the U.S.: <strong>Eppendorf</strong> North America 800-645-3050 · <strong>In</strong> Canada: <strong>Eppendorf</strong> Canada Ltd. 800-263-8715E-mail: info@eppendorf.com · www.eppendorf.com


168Multipurpose benchtop centrifugesCentrifuges 5804/5804 R and 5810/5810 RSimple operation‡‡Full-digit digital display for easy reading and reproducibleparameter setting‡‡Full labeled keys for intuitive programming of time, speed,g-force and temperature‡‡ShortSpin button for quick runs. Optional speed limitationprotect fragile tubes and delicate samples.‡‡Possibility for adapter-specific rotor radius adjustmentguarantees maximum RCF accuracy‡‡10 different acceleration and braking ramps to protectdelicate samples‡‡Saves up to 35 user-defined programs‡‡Separate FastTemp key for easy/intuitive starting of thepre-cooling program‡‡Standby button for energy savings3 | <strong>In</strong>struments | CentrifugationTechnical specificationsDescription Centrifuge 5804 Centrifuge 5804 R Centrifuge 5810 Centrifuge 5810 RMaximum g-force (rcf)• Swing-bucket rotor• Plate rotor• Fixed-angle rotorMaximum speedMaximum capacity• Swing-bucket rotor• Fixed-angle rotor4,500 x g2,250 x g20,817 x g200–14,000 rpm(in 10 rpm increments 1 )4 x 100 mL6 x 100 mL4,500 x g2,250 x g20,817 x g200–14,000 rpm(in 10 rpm increments 1 )4 x 100 mL6 x 100 mL4,500 x g3,486 x g20,817 x g200–14,000 rpm(in 10 rpm increments 1 )4 x 500 mL6 x 100 mL4,500 x g3,486 x g20,817 x g200–14,000 rpm(in 10 rpm increments 1 )4 x 500 mL6 x 100 mLNumber of rotors: 8 8 13 13Accel./Braking ramps 10/10 10/10 10/10 10/10Programs 35 user programs 35 user programs 35 user programs 35 user programsTimer1 min to 99 min, <strong>with</strong>continuous mode1 min to 99 min, <strong>with</strong>continuous mode1 min to 99 min, <strong>with</strong>continuous mode1 min to 99 min, <strong>with</strong>continuous modeNoise level• Rotor A-4-81 (4 x 500 mL)• Rotor A-4-44 (4 x 100 mL)• Rotor F-34-6-38 (6 x 100 mL)–


Multipurpose benchtop centrifuges169Centrifuges 5804/5804 R and 5810/5810 ROrdering informationDescription Catalog No. List USDCentrifuge 5804<strong>with</strong> 4 x 100 swing-bucket rotor (A-4-44), 120 V 022628203 $ 6,150.00<strong>with</strong>out rotor, 120 V 022622501 4,750.00<strong>with</strong>out rotor, 230 V 022622552 4,750.001-year Extended Warranty 901510569 570.00Centrifuge 5804 R (refrigerated)<strong>with</strong> 4 x 100 swing-bucket rotor (A-4-44), 120 V 022629964 8,730.00<strong>with</strong>out rotor, 120 V 022623508 8,090.00<strong>with</strong>out rotor, 120 V (20 Amp) 022625080 8,090.00<strong>with</strong>out rotor, 230 V 022623559 8,090.001-year Extended Warranty 901510640 975.00Centrifuge 5810<strong>with</strong> 4 x 500 swing-bucket rotor (A-4-81), 120 V 022627066 8,270.00<strong>with</strong> 4 x 250 swing-bucket rotor (A-4-62), 120 V 022627007 7,720.00<strong>with</strong>out rotor, 120 V 022625004 6,120.00<strong>with</strong>out rotor, 230 V 022625055 6,120.001-year Extended Warranty 901510577 735.00Centrifuge 5810 R (refrigerated)<strong>with</strong> 4 x 500 swing-bucket rotor (A-4-81), 120 V 022627082 11,370.00<strong>with</strong> 4 x 500 swing-bucket rotor (A-4-81), 120 V (20 Amp) 022627104 11,370.00<strong>with</strong> 4 x 250 swing-bucket rotor (A-4-62), 120 V 022627023 10,650.00<strong>with</strong>out rotor, 120 V 022625501 9,465.00<strong>with</strong>out rotor, 120 V (20 Amp)* 022625101 9,465.00<strong>with</strong>out rotor, 230 V 022625551 9,465.001-year Extended Warranty 901510642 1,150.003 | <strong>In</strong>struments | Centrifugation* Requires special dedicated 20 AMP outlet. Please check that the installation site can accommodate electrical requirements before ordering.<strong>In</strong> the U.S.: <strong>Eppendorf</strong> North America 800-645-3050 · <strong>In</strong> Canada: <strong>Eppendorf</strong> Canada Ltd. 800-263-8715E-mail: info@eppendorf.com · www.eppendorf.com


170Multipurpose benchtop centrifuge rotorsRotors and accessories for Centrifuges 5804/5804 R and 5810/5810 RCross-section of 6 x 100 mL rotor F-34-6-38showing the light-weight design. All metal notneeded for safety or performance is routed.3 | <strong>In</strong>struments | CentrifugationThe ergonomic solution for your lab.Elevate your centrifuge performance to a new level <strong>with</strong><strong>Eppendorf</strong> ® aluminum rotors. Selected aluminum alloys,advanced rotor design and unique product features willmake everyday routines faster and safer. All our rotorsbenefit you <strong>with</strong>:‡‡Low rotor weight —<strong>Eppendorf</strong>’s fixed-angle rotorsare among the lightest in the industry to improve handlingand operational safety. All metal that is not needed forsafety or performance is routed out for weight reduction.Check out the rotor weights on the next page and compareit to your current rotor.‡‡Maximum safety—aluminum is a well characterized metalproviding precise mathematic equations to determine rotorsafety. Manufacturing excellence, selection of aluminumalloys, vigorous testing for material integrity and postproductiontreatment ensure maximum rotor safety.Product features‡‡More ergonomic lifting and carrying due tolightweight design‡‡Lightweight rotors cause less wear and tear on themotor and allow for faster acceleration and braking times‡‡Rotors are designed for fast lid locking. Rotor 6 x 50 mLconical features a unique QuickLock aerosol-tight lidthat allows fast and ergonomic lid locking <strong>with</strong> only 1/4of a turn‡‡Low rotor profile design of 6 x 100 mL rotor providesunmatched tube accessibility for trouble-free tube removal‡‡All rotors are anodized for high chemical resistanceand to prevent corrosion‡‡Optimized design of rotor boreholes and adapters provideoptimal support for high-speed centrifugation of tubes‡‡Aluminum rotors are recyclable‡‡Superior temperature control—aluminum, <strong>with</strong> itshigh heat conductivity, combined <strong>with</strong> our light-weightdesign allows fast pre-cooling and accurate temperaturecontrol in refrigerated centrifugesOrder from your laboratory supply dealer.Product appearance, specifications, and/or prices are subject to change <strong>with</strong>out notice.


Multipurpose benchtop centrifuge rotors171Rotors and accessories for Centrifuges 5804/5804 R and 5810/5810 RTechnical specifications of rotors for Centrifuges 5804/5804 R and 5810/5810 R5804/5804 R5810/5810 R RotorSwing-bucket rotorsMax.capacityMax.rcf (x g)Max.(rpm)Max.radius(cm)Lowesttemp.at max.rpm 1Rotorweight(kg/lbs) 2Max. loadper bucket/bore 3Max.loadingheightfor platebuckets– ‡ A-4-81 5 4 x 500 mL 3,250 4,000 18.0


Multipurpose benchtop centrifuge rotors173Rotors exclusively for Centrifuges 5810 and 5810 RNEW!FPO - please send image500 mL and 400 mL wide-mouth bottles forRotor A-4-81, (polypropylene, centrifugationresistance up to 3,250 x g, autoclavable)Ordering informationMixed loading <strong>with</strong> 2 plate buckets and 2 rectangular tubebuckets is possible <strong>with</strong> Rotor A-4-81DescriptionMax. rotationalspeed (rpm)Max. rcf(x g)Rotorradius(cm) Catalog No. List USDRotor A-4-81 <strong>with</strong> 500 mL rectangular buckets 1Rotor A-4-81, incl. 4 x 500 mL rectangular buckets 4,000 3,250 18.0 022638602 $2,945.00Buckets, 500 mL rectangular, set of 4 022638629 1,320.00Aerosol-tight lids, for 500 mL rectangular buckets, set of 2 022638661 240.00Adapters: See pages 180 to 181500 mL wide-mouth bottle, set of 2 022638657 260.00400 mL wide-mouth bottle, incl. stabilizing sleeves, set of 2 022638653 260.00Spare rubber mat, for 500 mL bucket adapters, set of 4 022665201 21.00Spare adapter clamp, for 500 mL bucket adapters, set of 2 022638696 21.00Rotor A-4-81 <strong>with</strong> 7 x 50 mL conical bucketsRotor A-4-81, <strong>with</strong>out buckets 4,000 3,250 18.0 022638611 1,600.00Buckets, 7 x 50 mL conical tube, set of 4 4,000 3,250 18.0 022638614 1,320.00Adapter, 15 mL conical tube, set of 7 5820718005 325.00Adapters: See page 188 (Adapters for rotor FA-45-6-30 fit into 7 x 50 mL buckets)Rotor A-4-81 <strong>with</strong> MTP/Flex plate buckets 1Rotor A-4-81, incl. 4 x MTP/Flex plate buckets 4,000 2,900 16.3 022638807 3,480.00MTP/Flex buckets, set of 4 022638840 2,365.00MTP/Flex buckets, set of 2 022638866 1,185.00Adapter PCR 96-well plate, set of 2 4,000 2,880 16.1 022638947 168.00Adapter PCR 384-well plate, set of 2 4,000 2,820 15.8 022638955 168.00Adapter for IsoRack 24 x 0.5 mL tubes, set of 2 4,000 2,680 15.0 022638980 168.00Adapter for IsoRack 24 x 1.5/2 mL tubes, set of 2 4,000 2,600 14.6 022638998 168.00Spare rubber base plate for MTP/Flex bucket, set of 2 022638106 57.003 | <strong>In</strong>struments | Centrifugation* Aerosol-tightness tested by the Centre for Applied Microbiology and Research, CAMR, Porton Down, Great Britain.1Rotor A-4-81 and A-4-81-MTP/Flex can be used for all 120 V models starting <strong>with</strong> the following serial numbers: 5810 (≥2186), 5810 R (≥6203). If you own a unit <strong>with</strong> an older serial numbers please contact<strong>Eppendorf</strong> Customer Support at 800-645-3050, menu option 1 to learn about your options.<strong>In</strong> the U.S.: <strong>Eppendorf</strong> North America 800-645-3050 · <strong>In</strong> Canada: <strong>Eppendorf</strong> Canada Ltd. 800-263-8715E-mail: info@eppendorf.com · www.eppendorf.com


174Multipurpose benchtop centrifuge rotorsRotors exclusively for Centrifuges 5810 and 5810 R3 | <strong>In</strong>struments | Centrifugation4 x 250 mL Swing-bucket Rotor A-4-62‡‡All-in-one rotor for 4 x 250 mL rectangular buckets and4 MTP buckets‡‡Flexible adapters to accommodate a wide range of tubes‡‡With rectangular buckets max. speed:3,200 x g (4,000 rpm)‡‡Rotor, buckets, lids and adapters are autoclavable(121 °C, 20 min)‡‡Aerosol-tight 1 lids for safe centrifugation of hazardoussamples optionally availableRotor A-4-62 <strong>with</strong> plate buckets (A-4-62-MTP)‡‡Rotor A-4-62 can be upgraded <strong>with</strong> MTP buckets tospin plates‡‡Maximum speed: 2,750 x g (4,000 rpm)‡‡With a maximum loading height of 53 mm rotorA-4-62-MTP can handle up to:– 4 x 3 MTP– 4 x 2 Cell culture plates– 4 x 1 DWPOrdering informationDescriptionMax. rotationalspeed (rpm)Max. rcf(x g)Rotorradius(cm) Catalog No. List USDRotor A-4-62 <strong>with</strong> 250 mL rectangular bucketsRotor A-4-62, incl. 4 x 250 mL rectangular buckets 4,000 3,200 18.0 022638009 $2,080.00Buckets, 250 mL rectangular, set of 4 022638084 1,370.00Aerosol-tight lids 1 , for 250 mL rectangular buckets, set of 2 022638033 153.00Adapters: See pages 182 to 183Spare rubber mat, for 250 mL bucket adapters, set of 4 022638483 21.00Spare adapter clamp, for 250 mL bucket adapters, set of 2 022638467 21.00Rotor A-4-62 <strong>with</strong> MTP bucketsRotor A-4-62-MTP, incl. 4 x MTP buckets 4,000 2,750 15.4 022638041 2,540.00MTP buckets, set of 4 022638068 1,295.00Adapter PCR 96-well plate, set of 2 4,000 2,700 15.2 022638947 168.00Adapter PCR 384-well plate, set of 2 4,000 2,660 14.9 022638955 168.00Adapter for cell culture flasks, set of 2 4,000 022638972 168.00Adapter CombiSlide ® for up to 12 glass slides, set of 2 4,000 2,680 15.0 022638963 242.00Spare rubber base plate for MTP bucket, set of 2 022638106 57.001Aerosol-tightness tested by the Centre for Applied Microbiology and Research, CAMR, Porton Down, Great Britain.Order from your laboratory supply dealer.Product appearance, specifications, and/or prices are subject to change <strong>with</strong>out notice.


Multipurpose benchtop centrifuge rotors175Rotors for Centrifuges 5804/5804 R and 5810/5810 R4 x 100 mL Swing-bucket Rotor A-4-44‡‡Maximum rotational speed: 4,400 x g(max. 5,000 rpm)‡‡Broad range of adapters available to handle allcommon tube formats from 0.2 mL to 100 mL‡‡Aerosol-tight lids 1 for applications involving hazardousmaterials optionally available‡‡Rotor, buckets, lids and adapters are autoclavable(121 °C, 20 min)Rotor A-4-44 <strong>with</strong> 50 mL conical tube buckets‡‡50 mL conical tube buckets for medium throughputapplications‡‡Swing-bucket rotor provides high centrifugationspeed up to 4,500 x g (5,000 rpm)‡‡Form inserts to support conical tube bottoms included3 | <strong>In</strong>struments | CentrifugationOrdering informationDescriptionMax. rotationalspeed (rpm)Max. rcf(x g)4 x 100 mL Swing bucket Rotor A-4-44Rotor A-4-44, incl. 4 x 100 mL rectangular buckets 5,000 4,400 15.7 022637401 $1,525.005,000 4,500 16.1 022637461 2,180.00Rotor A-4-44, incl. 4 x 50 mL conical tube buckets,incl. conical form inserts1Aerosol-tightness tested by the Centre for Applied Microbiology and Research, CAMR, Porton Down, Great Britain.Rotorradius(cm) Catalog No. List USDBuckets, 100 mL rectangular, set of 4 022637436 1,200.00Buckets, 2 x 50 mL conical tube, incl. form inserts, set of 4 022637452 995.00Aerosol-tight lids 1 , for 100 mL rectangular buckets, set of 2 022637428 130.00Form inserts, for 50 mL conical tubes, set of 8 022637479 70.00Adapters for rotor A-4-44, see pages 184 to 185Spare rubber mat, for 100 mL bucket adapters, set of 4 022662503 21.00Spare adapter clamp, for 100 mL bucket adapters, set of 2 022662511 21.00<strong>In</strong> the U.S.: <strong>Eppendorf</strong> North America 800-645-3050 · <strong>In</strong> Canada: <strong>Eppendorf</strong> Canada Ltd. 800-263-8715E-mail: info@eppendorf.com · www.eppendorf.com


176Multipurpose benchtop centrifuge rotorsRotors for Centrifuges 5804/5804 R and 5810/5810 RNEW!Aerosol-tight deepwell plate Rotor A-2-DWP-AT 1Deepwell plate Rotor A-2-DWP3 | <strong>In</strong>struments | Centrifugation‡‡Maximum speed: 3,486 x g (4,500 rpm)‡‡For use in Models 5810 and 5810 R only‡‡Rotor can handle up to– 2 x 5 MTP– 2 x 4 Cell culture plates– 2 x 2 DWP– 2 x 1 Filtration plate kits‡‡Maximum loading height of 60 mm (89 mm <strong>with</strong>out lid)‡‡Rotor comes <strong>with</strong> aerosol-tight 2 lids for safe centrifugationof hazardous samples optionally availableOrdering informationDescriptionAerosol-tight deepwell plate Rotor A-2-DWP-AT 1Order from your laboratory supply dealer.Product appearance, specifications, and/or prices are subject to change <strong>with</strong>out notice.‡‡Maximum speed: 2,250 x g (3,700 rpm)‡‡Rotor can handle up to– 2 x 5 MTP– 2 x 4 Cell culture plates– 2 x 2 DWP– 2 x 1 Filtration plate kits‡‡Maximum loading height of 89 mm‡‡Rotor and buckets are autoclavable (20 min, 121 ºC)Max. rotationalspeed (rpm)Max. rcf(x g)Rotorradius(cm) Catalog No. List USDRotor A-2-DWP-AT, incl. buckets, aerosol-tight lids4,500 3,486 15.5 5820710004 $2,510.00and plate carrier 1Rotor A-2-DWP-AT, <strong>with</strong> software upgrade package 4 022639901 3,250.00Aerosol-tight lids 2 for rotor A-2-DWP-AT, set of 2 5820713003 294.00Plate carrier, set of 2 5820712007 253.00Spare buckets for A-2-DWP-AT, set of 2 5820711000 1,220.00Spare seals, for aerosol-tight plate rotor lids, set of 2 5820705000 63.00Deepwell plate Rotor A-2-DWP 3Rotor A-2-DWP, incl. 2 deepwell plate buckets 3,700 2,250 14.7 022638564 1,890.00Spare buckets for A-2-DWP, set of 2 022638556 690.00Spare rubber base plate for A-2-DWP buckets, set of 2 022638599 59.00Plate rotor adaptersAdapter PCR 96-well plate, set of 2 022638947 168.00Adapter PCR 384-well plate, set of 2 022638955 168.00Adapter for IsoRack 24 x 0.5 mL tubes, set of 2 022638980 168.00Adapter for IsoRack 24 x 1.5/2 mL tubes, set of 2 022638998 168.001A software upgrade may be necessary for model between serial numbers 10,000 (5804/5804 R/5810) / 12,000 (5810 R) and 60,000. Please contact your local <strong>Eppendorf</strong> representative or <strong>Eppendorf</strong> CustomerSupport at 800-645-3050, menu option 1 for more information. 2 Aerosol-tightness tested by the Centre for Applied Microbiology and Research, CAMR, Porton Down, Great Britain. 3 Rotor A-2-DWP can beused for all 120 V models starting <strong>with</strong> the following serial numbers: 5804 (≥1410), 5804R (≥1820), 5810 (≥990), 5810R (≥2949). If you own a unit <strong>with</strong> an older serial numbers please contact <strong>Eppendorf</strong> CustomerSupport at 800-645-3050, menu option 1 to learn about your options. 4 Software upgrade package includes an on-site software upgrade for one 58xx centrifuge by an <strong>Eppendorf</strong> service technician plus freepreventive maintenance inspection. Price includes software, travel and labor.


Multipurpose benchtop centrifuge rotors177Accessories for plate rotorsPCR plate adapter (PCR 96)‡‡PCR plate adapters are designed to supportthin-walled PCR plate wells during centrifugation‡‡Available for 96-well and 384-well PCR plates‡‡Adapters can be used in all <strong>Eppendorf</strong> ® plate rotorsIsoRack adapter (for 1.5/2 mL tube IsoRacks)‡‡IsoRack adapter supports 0.5 mL and 1.5/2 mLIsoRacks during centrifugation‡‡Adapters can be used in <strong>Eppendorf</strong> plate rotorsA-2-DWP and A-4-81-MTP/Flex3 | <strong>In</strong>struments | CentrifugationCell culture flask adapter‡‡Adapter to spin down cell cultures directly in acell culture flask‡‡Suitable for 25 cm 2 and certain 75 cm 2 flasks 1‡‡Adapters can be used in <strong>Eppendorf</strong> plate rotorsA-4-81-MTP/Flex and A-4-62-MTPCombiSlide ® adapter‡‡Designed for drying slides after hybridization experiments‡‡Adapter can hold up to 12 regular glass slides‡‡Removable inserts allow centrifugation of glass slidesacross and parallel to the direction of rotation‡‡Adapters can be used in all <strong>Eppendorf</strong> plate rotorsOrdering informationDescription Catalog No. List USDAdapter, for PCR 96-well plate, set of 2 022638947 $168.00Adapter, for PCR 384-well plate, set of 2 022638955 168.00Adapter, for plates <strong>with</strong> SBS footprint, set of 2 5825718003 168.00Adapter, for cell culture flasks, set of 2 5825719000 168.00IsoRack Adapter, for IsoRack 24 x 0.5 mL tubes, set of 2 022638980 168.00IsoRack Adapter, for IsoRack 24 x 1.5/2 mL tubes, set of 2 022638998 168.00IsoRack Adapter Starter Set, incl. IsoRacks (2 x 1.5/2 mL and 2 x 0.5 mL), IsoPack cool packs 022510070 425.00for 0 °C (2 x 1.5/2 mL and 2 x 0.5 mL), IsoRack centrifuge adapters (2 x 1.5/2 mL and 2 x 0.5 mL)CombiSlide adapter, for up to 12 glass slides, set of 2 022638963 242.001Suitable for the following 75 cm 2 flasks: Nunc ® (e.g., Catalog Nos. 156472, 156499), Greiner (e.g., Catalog Nos. 658170, 658175, 658190, 658195), Sarstedt (Catalog Nos. 83.1811 and 83.1811.002).Please perform a manual swing-out test before centrifugation.<strong>In</strong> the U.S.: <strong>Eppendorf</strong> North America 800-645-3050 · <strong>In</strong> Canada: <strong>Eppendorf</strong> Canada Ltd. 800-263-8715E-mail: info@eppendorf.com · www.eppendorf.com


178Multipurpose benchtop centrifuge rotorsRotors for Centrifuges 5804/5804 R and 5810/5810 RNEW!3 | <strong>In</strong>struments | Centrifugation6 x 100 mL Fixed-angle Rotor F-34-6-38‡‡Basic rotor for high-speed centrifugation of tubes from0.2 mL to 100 mL‡‡Maximum speed: 15,500 x g (11,000 rpm) or 18,500 x g(12,000 rpm) when used in Model 5810 R‡‡Low rotor profile <strong>with</strong> domed rotor lid provides unmatchedtube accessibility and trouble-free tube removal‡‡<strong>Eppendorf</strong>’s advanced rotor design minimizes weightfor easy lifting and carrying (weight incl. lid: 3.19 kg.)See page 170 for more information.‡‡34° borehole angle reduces pellet smears along tube wall‡‡Adapters for 50 mL and 15 mL conical tubes and othertube sizes available. See page 186 for more information.Aerosol-tight 6 x 50 mL conical tube Rotor FA-45-6-30 1‡‡Rotor for high-speed centrifugation of tubes up to 50 mL‡‡Aerosol-tight 2 rotor rid for safe centrifugationof hazardous samples‡‡Maximum speed: 16,639 x g (11,000 rpm) or 20,130 x g(12,100 rpm) when used in Model 5810 R‡‡Rotor features a unique QuickLock closure for fastand reliable lid locking‡‡<strong>Eppendorf</strong>’s advanced rotor design minimizes weightfor easy lifting and carrying (weight incl. lid: 3.17 kg)‡‡45° borehole angle for compact pellets at the bottom ofthe tube—minimizes pellets smear along the tube wall‡‡Adapters for 15 mL conical and other tubes availableOrdering informationDescription6 x 100 mL Fixed-angle Rotor F-34-6-38Max.rotationalspeed (rpm) 3Rotor F-34-6-38 for 6 x 100 mL tubes incl. lid 11,000/12,000(5810 R)(x g) 3 (cm) Catalog No. List USDMax. rcfRotorradius15,500/18,500(5810 R)11.5 022637207 $2,190.00Rotor lid, for rotor F-34-6-38 022662961 525.00Adapters, see pages 186 to 187Aerosol-tight 6 x 50 mL conical tube Rotor FA-45-6-30Rotor FA-45-6-30 for 6 x 50 mL conical tubes,11,000/12,100 16,639/20,130 12.3 5820715006 2,335.00<strong>with</strong> aerosol-tight QuickLock lidRotor FA-45-6-30, <strong>with</strong> software upgrade package 4 022639903 3,050.00Rotor lid, for rotor FA-45-6-30, aerosol-tight 2 5820716002 254.00Spare seals, for aerosol-tight rotor lid FA-45-6-30, set of 5 022652109 129.00Adapters, see page 1881A software upgrade may be necessary for model between serial numbers 10,000 (5804/5804 R/5810) / 12,000 (5810 R) and 60,000. Please contact your local <strong>Eppendorf</strong> representative or <strong>Eppendorf</strong> CustomerSupport at 800-645-3050, menu option 1 for more information.2Tested by the Centre for Applied Microbiology and Research, CAMR, Porton Down, Great Britain.3Lower valve refers to use in 5804/5804 R/5810.4Software upgrade package includes an on-site software upgrade for one 58xx centrifuge by an <strong>Eppendorf</strong> service technician plus free preventive maintenance inspection. Price includes software, travel and labor.Order from your laboratory supply dealer.Product appearance, specifications, and/or prices are subject to change <strong>with</strong>out notice.


Multipurpose benchtop centrifuge rotors179Rotors for Centrifuges 5804/5804 R and 5810/5810 R30-place Fixed-angle Rotors F-45-30-11 and FA-45-30-11‡‡For 1.5/2.0 mL tubes‡‡Maximum speed: 20,800 x g (14,000 rpm)‡‡Rotor, lids and adapters are autoclavable (121 °C, 20 min)– Rotor FA-45-30-11 <strong>with</strong> lid can be autoclaved for 2 hat 140 °C to destroy prion contamination‡‡High-quality, extremely robust aluminum lid forboth rotors‡‡Aerosol-tight 2 centrifugation possible <strong>with</strong> rotorFA-45-30-1160 x 1.5/2.0 mL Drum Rotor T-60-11‡‡High capacity for 60 x 1.5/2.0 mL tubes‡‡Speed up to 16,400 x g (14,000 rpm)‡‡Horizontal centrifugation for pellet formation at tubebottom—ideal for low sample quantitiesPCR-strip Rotor F-45-48-PCR‡‡Accommodates up to 6 x 5/8-tube PCR strips or48 x 0.2 mL PCR tubes‡‡Safe and easy handling <strong>with</strong>out additional lid3 | <strong>In</strong>struments | CentrifugationOrdering informationDescriptionMax. rotationalspeed (rpm)Max. rcf(x g)Rotorradius(cm) Catalog No. List USD30 x 1.5/2.0 mL Fixed-angle RotorsRotor FA-45-30-11, incl. aerosol-tight lid 14,000 20,800 9.5 022637100 $1,460.00Rotor lid, for FA-45-30-11 rotor, aerosol-tight 022637126 229.00Rotor F-45-30-11, incl. lid 14,000 20,800 9.5 022637002 1,075.00Rotor lid, for F-45-30-11 rotor 022662970 185.00Adapter for 0.2 mL PCR tubes (for 1.5/2 mL rotors), set of 6 14,000 16,200 7.4 022636260 31.00Adapter for 0.4 mL tubes (for 1.5/2 mL rotors), set of 6 14,000 20,800 9.5 022636243 31.00Adapter for 0.5 mL tubes (for 1.5/2 mL rotors), set of 6 14,000 18,400 8.4 022636227 31.00Adapter for BD Microtainer ® (for 1.5/2 mL rotors), set of 6 14,000 20,800 9.5 022636227 31.0060 x 1.5/2.0 mL Drum Rotor T-60-11 2Drum rotor T-60-11, <strong>with</strong> lid, <strong>with</strong>out adapters 14,000 16,400 7.5 022638505 2,540.00Adapter for 10 x 1.5/2 mL tubes (Ø 11 mm), set of 6 14,000 16,400 7.5 022638521 450.00Adapter for 20 x 0.4 mL tubes (Ø 6 mm), set of 6 14,000 16,400 7.5 022638548 450.00PCR strip Fixed-angle Rotor F-45-48-PCR 1Rotor F-45-48-PCR, for 6 x 8-tube PCR strips 12,000 15,350 9.5 022638581 1,890.001Rotor F-45-48-PCR can be used for all 120 V models starting <strong>with</strong> the following serial numbers: 5804 (≥2904), 5804 R (≥3861), 5810 (≥2366), 5810 R (≥6743).2Rotor T-60-11 can be used for all 120 V models starting <strong>with</strong> the following serial numbers: 5804 (≥1410), 5804 R (≥1820), 5810 (≥990), 5810 R (≥2949). If you own a centrifuge <strong>with</strong> an older serial numberplease contact <strong>Eppendorf</strong> Customer Support at 800-645-3050, menu option 1 to learn about your options.<strong>In</strong> the U.S.: <strong>Eppendorf</strong> North America 800-645-3050 · <strong>In</strong> Canada: <strong>Eppendorf</strong> Canada Ltd. 800-263-8715E-mail: info@eppendorf.com · www.eppendorf.com


180 Multipurpose benchtop centrifuge rotorsRotors exclusively for Centrifuges 5810/5810 RDescriptionA-4-81Swing-bucket rotor, <strong>with</strong>rectangular buckets, 4 x 500 mLReplacementrectangular buckets,500 mL, set of 4Aerosol-tight lid, for rectangularbuckets, set of 2Max. rcf (x g) 3,250Max. rotational speed (rpm) 4,000Catalog No. 022638602 022638629 022638661List USD $2,945.00 $1,320.00 $240.003 | <strong>In</strong>struments | CentrifugationTubeTube capacity (mL) 1.5/2 1.2–5 2.6–5 2.6–7 3–15 7–17Max. tube length for all positions (mm) 1 118 118 118 118 118 (130 mm intwo inner rows 1 )118 (130 mm intwo inner rows 1 )Max. tube length for use108 108 108 108 108 (130 mm in<strong>with</strong> aerosol-tight lid (mm) 1 four inner pos. 1 )Form inserts for 50 mL conical tubes, skirted118 (130 mm infour inner pos. 1 )Adapter – – – –– –Catalog No. (set of 8 adapters) – – – – – –List USD – – – – – –Adapter for 500 mL rectangular bucketAdapterNumber of tubesper adapter/per rotor20/80 20/80 25/100 18/72 16/64 16/64Adapter bore (Ø mm) 11 11 13 13 16 17.5Adapter bottom shape flat flat <strong>with</strong>rubber matflat <strong>with</strong>rubber matflat <strong>with</strong>rubber matflat <strong>with</strong>rubber matflat <strong>with</strong>rubber matMax. rcf (g-force) 2,950 3,000 3,000 3,000 3,000 3,000Centrifugation radius (cm) 16.5 16.8 16.8 16.8 16.8 16.8Max. rotational speed (rpm) 4,000 4,000 4,000 4,000 4,000 4,000Catalog No. (set of 2 adapters) 022638704 022638707 022638700 022638718 022638721 022638726List USD $274.00 $274.00 $274.00 $274.00 $274.00 $274.001Exceeding the maximum tube length may reduce the loading capacity of the rotor. Please perform amanual swing-out test before starting the centrifuge run to make sure the tubes do not hit the rotor yoke.2Only Centriprep ® tube <strong>with</strong>out locking lid.3For high g-forces we recommend using centrifuge tubes of Duran ® glass.Order from your laboratory supply dealer.Product appearance, specifications, and/or prices are subject to change <strong>with</strong>out notice.4 Suitable for the following high-volume conical bottles: BD Falcon ® 175 mL, Nunc ® 200 mL, Conicalform-insert offered by the tube manufacturers must be used to support the conical part of the tubeduring centrifugation.5Available as a set of 2 flasks (see ordering information page 173).


Multipurpose benchtop centrifuge rotors181Rotors exclusively for Centrifuges 5810/5810 R7 x 50 mL conical buckets,set of 4MTP/Flex bucketset of 4 set of 23,250 2,9004,000 4,000022638614 022638840 022638866$1,320.00 $2,365.00 $1,185.0015 mL conical 50 mL conical 50 mLCentri prep ®2330–50 mL andconical skirted180–250 400 mL bottle 5(022638653)500 mL bottle 5(022638657)121 122 121 119 133 135 135119 116 – – – 1354<strong>Eppendorf</strong><strong>Eppendorf</strong>3 | <strong>In</strong>struments | Centrifugation– – – – – –– – – 022654373 – – –– – – $225.00 – – –no adapterneeded12/48 5/20 5/20 1/4 1/4 1/417.5 31 31 62 81 –conical conical flat <strong>with</strong> rubber mat flat <strong>with</strong> rubbermatflat, rubber –3,100 3,100 3,100 3,100 3,250 3,25017.3 17.3 17.3 17.3 18.0 18.04,000 4,000 4,000 4,000 4,000 4,000022638742 022638769 022638904 022638921 022638785 –$274.00 $274.00 $274.00 $274.00 $274.00 –<strong>In</strong> the U.S.: <strong>Eppendorf</strong> North America 800-645-3050 · <strong>In</strong> Canada: <strong>Eppendorf</strong> Canada Ltd. 800-263-8715E-mail: info@eppendorf.com · www.eppendorf.com


182 Multipurpose benchtop centrifuge rotorsRotors exclusively for Centrifuges 5810/5810 RDescriptionA-4-62Swing-bucket rotor, <strong>with</strong>rectangular buckets, 4 x 250 mLReplacementrectangular buckets,250 mL, set of 4Aerosol-tight lid, for rectangularbuckets, set of 2Max. rcf (x g) 3,200Max. rotational speed (rpm) 4,000Catalog No. 022638009 022638084 022638033List USD $2,080.00 $1,370.00 $153.003 | <strong>In</strong>struments | CentrifugationTubeTube capacity (mL) 1.5–2 1.2–5 2.6–7 3–15 7–17Max. tube length for all positions (mm) 1 122 123 121 121 (130 mm intwo inner rows 1 )Max. tube length for use118 115 118 116 (130 mm in<strong>with</strong> aerosol-tight lid (mm) 1 two inner pos. 1 )Form inserts for 50 mL conical tubes118 (130 mm intwo inner rows 1 )114 (130 mm intwo inner pos. 1 )Adapter – – – – –Catalog No. (set of 8 adapters) – – – – –List USD – – – – –Adapter for 250 mL rectangular bucketAdapterNumber of tubesper adapter/per rotor16/64 25/100 15/60 12/48 12/48Adapter bore (Ø mm) 11 11 13 16 17.5Adapter bottom shape flat flat <strong>with</strong>rubber matflat <strong>with</strong>rubber matflat <strong>with</strong>rubber matflat <strong>with</strong>rubber matMax. rcf (g-force) 3,000 3,050 3,050 3,050 3,050Centrifugation radius (cm) 17.1 17.3 17.3 17.3 17.3Max. rotational speed (rpm) 4,000 4,000 4,000 4,000 4,000Catalog No. (set of 2 adapters) 022638220 022638203 022638246 022638262 022638301List USD $274.00 $274.00 $274.00 $274.00 $274.001Exceeding the maximum tube length may reduce the loading capacity of the rotor. Please perform amanual swing-out test before starting the centrifuge run to make sure the tubes do not hit the rotor yoke.2When using 50 mL Falcon ® tubes in the adapter, the aerosol-tight lid can no longer be closed.3Suitable for the following high-volume conical bottles: BD Falcon ® 225 mL, BD Falcon 175 mL,Nunc ® 200 mL, Nalgene 175 mL, Conical form-insert offered by the tube manufacturers must beused to support the conical part of the tube during centrifugation.Order from your laboratory supply dealer.Product appearance, specifications, and/or prices are subject to change <strong>with</strong>out notice.


Multipurpose benchtop centrifuge rotors183Rotors exclusively for Centrifuges 5810/5810 RMTP bucket,set of 42,7504,000022638068$1,295.0015 mLconical7–18 18–30 50 mLconical450 mLconical2 2430–50 mL andconical skirted450–75 80–120 180–250127 126 119 122 122 119 122 139 136121 119 116 116 – 113 118 125 127433 | <strong>In</strong>struments | Centrifugation– – – – – – –– – – – 022637479 022654373 – – –– – – – $70.00 $225.00 – – –522,59/36 8/32 4/16 3/12 4/16 4/16 2/8 1/4 1/417.5 20 26 31 31 31 35 45 62conicalflat <strong>with</strong>rubber matflat <strong>with</strong>rubber mat4For high g-forces we recommend using centrifuge tubes of Duran ® glass.5Form inserts for 50 mL conical tubes included in delivery.conicalflat w/conicalform insert 5flat <strong>with</strong>rubber matflat <strong>with</strong>rubber matflat <strong>with</strong>rubber matflat <strong>with</strong>rubber mat3,150 3,050 3,050 3,150 3,050 3,050 3,050 3,050 3,20017.8 17.3 17.3 17.8 17.3 17.3 17.3 17.3 18.04,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000 4,000022638289 022638327 022638360 022638343 022638351 022638386 022638408 022638424 022638441$274.00 $274.00 $274.00 $274.00 $274.00 $274.00 $274.00 $274.00 $274.00<strong>In</strong> the U.S.: <strong>Eppendorf</strong> North America 800-645-3050 · <strong>In</strong> Canada: <strong>Eppendorf</strong> Canada Ltd. 800-263-8715E-mail: info@eppendorf.com · www.eppendorf.com


184 Multipurpose benchtop centrifuge rotorsRotors for Centrifuges 5804/5804 R and 5810/5810 R3,4DescriptionA-4-44Swing-bucket rotor,<strong>with</strong> rectangular buckets,4 x 100 mLReplacementrectangular buckets,100 mL, set of 4Aerosol-tight lid,for rectangular buckets,set of 22 x 50 mL conical tubebuckets, set of 4Max. rcf (x g) 4,500 4,400 4,500Max. rotational speed (rpm) 5,000 5,000 5,000Catalog No. 022637401 022637436 022637428 022637452List USD $1,525.00 $1,200.00 $130.00 $995.003 | <strong>In</strong>struments | CentrifugationTubeTube capacity (mL) 1.5–2 1.2–5 2.6–7 3–15 7–17 15 mLconicalMax. tube length for all positions (mm) 1 111 105 108 108 110 1212Max. tube length for use105 102 106 106 106 –<strong>with</strong> aerosol-tight lid (mm) 1Form inserts for 50 mL conical tubesAdapter – – – – – –Catalog No. (set of 8 adapters) – – – – – –List USD – – – – – –Adapter for 100 mL rectangular bucketAdapterNumber of tubesper adapter/per rotor12/48 14/56 9/36 7/28 6/24 4/16Adapter bore (Ø mm) 11 11 13 16 17.5 17.5Adapter bottom shape flat flat <strong>with</strong>rubber matflat <strong>with</strong>rubber matflat <strong>with</strong>rubber matflat <strong>with</strong>rubber matMax. rcf (g-force) 4,100 4,200 4,200 4,200 4,200 4,300Centrifugation radius (cm) 14.8 15.0 15.0 15.0 15.0 15.5Max. rotational speed (rpm) 5,000 5,000 5,000 5,000 5,000 5,000Catalog No. (set of 2 adapters) 022637525 022637509 022637541 022637568 022637584 022637606List USD $228.00 $228.00 $228.00 $228.00 $228.00 $228.00conical1Exceeding the maximum tube length may reduce the loading capacity of the rotor. Please perform amanual swing-out test before starting the centrifuge run to make sure the tubes do not hit the rotor yoke.2Tube may only be centrifuged <strong>with</strong>out the locking lid.3Form inserts for 50 mL conical tubes included in delivery.Order from your laboratory supply dealer.Product appearance, specifications, and/or prices are subject to change <strong>with</strong>out notice.


Multipurpose benchtop centrifuge rotors185Rotor accessories for Centrifuges 5804/5804 R and 5810/5810 R15 mLconical7–18 18–30 50 mLconical50 mLconical50 mLconical30–50 50 mLconicalskirted550–75 80–100121 107 110 122 122 120 122 119 11453 | <strong>In</strong>struments | Centrifugation121 104 100 – 119 – 108 108 100– – – – – – – –– – – – – 022637479 – 022654373 – –– – – – – $70.00 – $225.00 – –33,42/8 4/16 2/8 1/4 1/4 2/8 1/4 1/4 1/417.5 20 26 31 31 31 31 35 45conicalflat <strong>with</strong>rubber matflat <strong>with</strong>rubber matconical conical flat w/conicalform insert 3 flat <strong>with</strong> rubber mat flat <strong>with</strong>rubber matflat <strong>with</strong>rubber mat4,400 4,200 4,200 4,300 4,400 4,500 4,200 4,200 4,20015.7 15.0 15.0 15.5 15.7 16.1 15.0 15.0 15.05,000 5,000 5,000 5,000 5,000 5,000 5,000 5,000 5,000022637614 022637622 022637649 022637665 022637673 022637452 6 022637681 022637703 022637720$228.00 $228.00 $228.00 $228.00 $228.00 $995.00 $228.00 $228.00 $228.004Filled conical tubes may be used in the 50 mL Falcon ® buckets when they do not exceed a cumulativemaximum weight of 0.14 kg.5For high g-forces we recommend using centrifuge tubes of Duran ® glass.6Set of 4 buckets.<strong>In</strong> the U.S.: <strong>Eppendorf</strong> North America 800-645-3050 · <strong>In</strong> Canada: <strong>Eppendorf</strong> Canada Ltd. 800-263-8715E-mail: info@eppendorf.com · www.eppendorf.com


186 Multipurpose benchtop centrifuge rotorsRotors for Centrifuges 5804/5804 R and 5810/5810 RDescriptionF-34-6-38High-speed fixed-angle rotor,<strong>with</strong> screw-on lid, for 6 x 100 mL tubesMax. rcf (x g) 15,550/18,500 (in 5810 R)Max. rotational speed (rpm) 11,000/12,000 (in 5810 R)Catalog No. 022637207 022662961List USD $2,190.00 $525.00Replacement lidfor fixed-angle rotor F-34-6-38Tube3 | <strong>In</strong>struments | Centrifugation(Please observe the limitsfor the load-bearing capacityof the tubes as specifiedby the tube manufacturer)Tube capacity (mL) 1.5–2 13 x 75 mm 13 x 100 mm 7–15 15 mL conicalMax. tube length for all positionsunder the rotor lid (mm)Adapter for 6 x 100 mL fixed-angle rotorAdapter110 90 110 112 123Number of tubesper adapter/per rotor4/24 3/18 3/18 2/12 1/6Adapter bore (Ø mm) 11 13 13 16 17.5Adapter bottom shape round flat flat round conicalMax. rcf (g-force)at 11,000 rpm (5804/ 5804 R/ 5810)Max. rcf (g-force)at 12,000 rpm (5810 R)15,300 14,339 15,422 15,150 14,45018,200 17,065 18,353 18,000 17,200Centrifugation radius (cm) 11.3 10.6 11.4 11.2 10.7Max. rotational speed for 4 °C 11,000 11,000 11,000 11,000 11,000Catalog No. (set of 2 adapters) 022637215 022637279 022637282 022637223 022637274List USD $150.00 $150.00 $150.00 $150.00 $150.00Adapters, lid and rotor are autoclavable at 121 °C, 20 min.Please confirm from tube manufacturer centrifugation resistance of tubes prior to use.1Nominal tube volume as published by the tube manufacturer.Order from your laboratory supply dealer.Product appearance, specifications, and/or prices are subject to change <strong>with</strong>out notice.


Multipurpose benchtop centrifuge rotors187Rotors for Centrifuges 5804/5804 R and 5810/5810 RRotor code:All <strong>Eppendorf</strong> ® rotors areidentified using a simple,alphanumeric format thatrepresents the technicalspecifications in a uniformseries of letters and numbers.Fixed-anglerotorAngle ofadapter boreØ Tube/adapterSwing-bucket rotorØ Tube/adapterboreF A 45 30 11 A 4 81Aerosol-tightversionMax. no. tubes/adaptersMax. no.buckets/adapters15–18 20–30 50 50 mL conical 85–100 1123 123 123 121 1213 | <strong>In</strong>struments | Centrifugationno adapter needed1/6 1/6 1/6 1/6 1/618 26 29 30 38round round round conical –14,750 14,900 15,150 14,600 15,55017,550 17,700 18,000 17,400 18,50010.9 11.0 11.2 10.8 11.511,000 11,000 11,000 11,000 11,000022637231 022637240 022637258 022637266 –$150.00 $150.00 $150.00 $150.00 –<strong>In</strong> the U.S.: <strong>Eppendorf</strong> North America 800-645-3050 · <strong>In</strong> Canada: <strong>Eppendorf</strong> Canada Ltd. 800-263-8715E-mail: info@eppendorf.com · www.eppendorf.com


188Multipurpose benchtop centrifuge rotorsRotors for Centrifuges 5804/5804 R and 5810/5810 RDescriptionFA-45-6-30Aerosol-tight high-speed rotor for volumesup to 50 mL <strong>with</strong> QuickLock lidReplacement QuickLock lid,aerosol-tightMax. rcf (x g) 16,639/20,130 (in 5810 R)Max. rotational speed (rpm) 11,000/12,100 (in 5810 R)Catalog No. 5820715006 5820716002List USD $2,335.00 $254.00Tube3 | <strong>In</strong>struments | Centrifugation(Please observe the limitsfor the load-bearing capacityof the tubes as specifiedby the tube manufacturer)Tube capacity (mL) 7–15 15 conical 15–18 20–30 35 50Max. tube length for all positionsunder the rotor lid (mm)Adapter for 6 x 100 mL fixed-angle rotorAdapter115 125 125 125 121no adapterneededNumber of tubesper adapter/per rotor1/6 1/6 1/6 1/6 1/6 1/6Adapter bore (Ø mm) 16 17.5 18 26 29 29Adapter bottom shape round conical round round conical conicalMax. rcf (g-force)at 11,000 rpm (5804/ 5804 R/ 5810)Max. rcf (g-force)at 12,100 rpm (5810 R)16,233 16,233 16,233 14,204 15,151 16,36919,642 19,642 19,642 17,187 18,333 20,130Centrifugation radius (cm) 12.0 12.0 12.0 10.5 11.2 12.3Max. rotational speed for 4 °C 11,000 11,000 11,000 11,000 11,000 11,000Catalog No. (set of 2 adapters) 5820719001 5820717009* 5820720000 5820721006 5820722002 –List USD $150.00 $150.00 $150.00 $150.00 $150.00 –Adapters, lid and rotor are autoclavable at 121 °C, 20 min.Please confirm from tube manufacturer centrifugation resistance of tubes prior to use.* Also available as a set of 7, Cat. No. 5820718005 (List USD $325.00)Order from your laboratory supply dealer.Product appearance, specifications, and/or prices are subject to change <strong>with</strong>out notice.


Centrifuge accessories189Captain Eppi and Rotor keysDescriptionThe days of disorder and chaos ruling the lab are over—beholdCaptain Eppi! He grabs hold of rotor keys so that they no longerdisappear in cupboards or dark corners. And not only that:Captain Eppi provides a safe home for your pens and otherlab utensils.Captain Eppi is the mascot for world-renown <strong>Eppendorf</strong> Tubes ® ,standing for quality, reliability and safety. We’re certain thatyou’ll soon be hearing in your lab, “Where is the rotor key?—Ask Captain Eppi!”Who is he/What is he?‡‡Your benchtop rotor key holder‡‡<strong>Eppendorf</strong> centrifuge tube mascot‡‡Made of durable plastic‡‡Versatile3 | <strong>In</strong>struments | CentrifugationJoin Captain Eppi in our Virtual Labs and learnmore about interesting applications and productswww.eppendorfna.com/virtual-labOrdering informationDescription Catalog No. List USDCaptain Eppi1 piece 022639609 $ 22.00set of 10 022639625 178.00Rotor key10 mm socket wrench, fits standard 24 x 1.5/2.0 mL or 36 x 0.5 mL rotor,022667181 17.00for Models 5415 D and 5415 R5 mm Allen key, fits all rotors for Models 5417 C, 5417 R, 5418, 5424, 5430, 5702 series022634305 17.00and 5415 D/5415 R aerosol-tight rotor6 mm Allen key, fits all rotors for 5804, 5804 R, 5810 and 5810 R except 4 x 400 mL rotor022664166 17.00(A-4-81-MTP/Flex)7 mm Allen key, fits 4 x 500 mL swing bucket rotor (A-4-81 and A-4-81-MTP/Flex) 022664174 26.00Torque wrench rotor key for 24-place high-speed rotor FA-45-24-11-HS for 5430, 5430 R 5427350012 65.00Rotor standFits all rotors for Centrifuges 5804/5804 R and 5810/5810 R 022639021 117.00<strong>In</strong> the U.S.: <strong>Eppendorf</strong> North America 800-645-3050 · <strong>In</strong> Canada: <strong>Eppendorf</strong> Canada Ltd. 800-263-8715E-mail: info@eppendorf.com · www.eppendorf.com


190 Service productsCentrifuge Service ProductsService for peace of mind and the long <strong>life</strong> of your <strong>Eppendorf</strong> ® centrifugeWe have developed service programs and options tailored to your needs in order to ensure yourcentrifuge is operating consistently at peak performance. You probably purchased an <strong>Eppendorf</strong>centrifuge because of the value you expect from its features—high quality, excellent design andreliability. Now you can further extend that value and the <strong>life</strong> of your centrifuge through <strong>Eppendorf</strong>service and support.For more information go to www.eppendorfna.com/service3 | Service | CentrifugationExtended WarrantyYour new <strong>Eppendorf</strong> Centrifuge comes <strong>with</strong> a 2-yearwarranty which covers all parts and labor should thesystem ever need repair. When you purchase yourcentrifuge or when the warranty period is over 1 youmay also purchase up to 3 additional years of warrantycoverage. Most systems are returned to our ServiceCenter for repair and Field Service is available <strong>with</strong>travel zone charge for larger multipurpose centrifuges.1-year Extended Warranty for: Catalog No. List USDMiniSpin/plus 901510561 $ 180.00Centrifuge 5418 901510562 250.00Centrifuge 5418 R 901510661 700.00Centrifuge 5424 901510563 295.00Centrifuge 5424 R 901510649 690.00Centrifuge 5430 901510644 425.00Centrifuge 5430 R 901510646 925.00Centrifuge 5415 R 901510565 700.00Centrifuge 5417 R 901510571 935.00Centrifuge 5702 901510566 250.00Centrifuge 5702 R 901510567 620.00Centrifuge 5702 RH 901510568 730.00Centrifuge 5804 901510569 570.00Centrifuge 5804 R 901510640 975.00Centrifuge 5810 901510577 735.00Centrifuge 5810 R 901510642 1,150.00Advantage Repair ServiceAn easy to use value packaged service option when arepair is needed for systems not covered under a warrantyor extended warranty. All it takes is one call to our ServiceCenter and for a single fee we will repair the instrument,complete a full preventive maintenance, repair anythingelse we find, plus include a full year warranty on the wholesystem, not just the repair. <strong>In</strong>strument return shipment isalso included.Advantage Repair Service for: Catalog No. List USDMiniSpin/plus 901520000 $ 348.00Centrifuge 5418 901520010 540.00Centrifuge 5418 R 901520074 1,392.00Centrifuge 5424 901520012 634.00Centrifuge 5424 R 901520072 1,372.00Centrifuge 5430 901520014 923.00Centrifuge 5430 R 901520016 1,973.00Centrifuge 5415 R 901520004 1,511.00Centrifuge 5417 R 901520008 2,022.00Centrifuge 5702 901520018 546.00Centrifuge 5702 R 901520020 1,339.00Centrifuge 5702 RH 901520022 1,581.00Centrifuge 5804 901520024 1,235.00Centrifuge 5804 R 901520026 2,103.00Centrifuge 5810 901520028 1,591.00Centrifuge 5810 R 901520030 2,461.001An extended warranty can be purchased during the manufacturer’s warranty period.<strong>In</strong>struments that are no longer under manufacturer’s warranty require a preventivemaintenance evaluation, before an extended warranty can be purchased.On-demand Repair ServiceService is available on demand when a repair is neededto restore a system’s performance. Parts and labor arecharged at prevailing rates. Shipping to and from theService Repair Center is not included and Field Service isavailable upon request for an additional zone travel charge.A 90-day warranty is provided on the repair.For On-demand Repair Service, call 800-645-3050,menu option 1.Order direct from <strong>Eppendorf</strong> North America.Product appearance, specifications, and/or prices are subject to change <strong>with</strong>out notice.


Service products191Value of ServiceQuality management systems increasingly ask for regularinspections of centrifuges and rotors to guaranteeperformance according to manufacturer’s specifications andensure a safe work environment. <strong>Eppendorf</strong> recommendsan annual inspection by an <strong>Eppendorf</strong> certified servicetechnician. The services presented below provide assurancethat your centrifuge and rotors are performing properly.Whether it’s a professional installation at the start orrecommended annual reviews of performance, we havethe right service and documentation to support your needs.Your benefits‡‡Maximum safety for you and your samples‡‡Longer <strong>life</strong>time of your centrifuge‡‡Regulatory compliance for GLP, GMP, ISO 9001or other quality management systemsPreventive Maintenance (PM)PM is recommended annually to ensure centrifugesare performing to manufacturer’s specifications for anextensive <strong>life</strong>time. Centrifuge preventive maintenanceprovides cleaning, lubricating and a standard visual checkof all sensitive parts. This includes a detailed hardware andelectronic evaluation by visual inspection, function check,and a software update if required. A visual inspection of arotor for any defects is also included. A subsequent testrun is performed. During this process, labor is includedfor any additional repairs identified for the instrument tomeet specification. Additional repair parts are not includedbut provided at a discount. A service report is provided; adated and signed sticker is affixed to the centrifuge.Preventive Maintenance for: Catalog No. List USDNON-Refrigerated Centrifuge 901510520 $195.00Refrigerated Centrifuge 901510522 245.00CertificationFor more specific information and documentation,a Certification will meet clinical and most regulatedlaboratory needs for annual inspection. All the elementsof Preventive Maintenance are included. Additionally,specific performance results are measured by NISTtraceable equipment and documented on a numberedcertificate according to <strong>Eppendorf</strong> manufacturer’sspecifications. The Certification is valid for 1-yearand an electronic record is maintained for 3-years.<strong>In</strong>stallation Qualification andOperational Qualification (IQ/OQ)Designed to support customers in regulated environments,IQ/OQ assures and documents instrument installationand operation for performance and defined functions.Testing is completed at the customer location accordingto <strong>Eppendorf</strong> ® manufacturer’s specification. Documentedtraining for a key operator is also included. Operationalqualification includes a full function test of: speed, overspeedcut-off, acceleration, deceleration, braking efficiency,temperature, imbalance cut-off, timer and lid latch.IQ/OQ for: Catalog No. List USDNON-Refrigerated Centrifuge 901510510 $ 950.00Refrigerated Centrifuge 901510512 1,050.00Rotor inspectionTo maintain safety and performance, rotors should alsobe regularly inspected to ensure their integrity. Rotorsundergo significant stress forces and depending on theusage and application their condition and suitability foroperation can vary. A documented proactive cleaning andvisual inspection by a qualified <strong>Eppendorf</strong> technician canhelp prolong the safe and consistent performance of bothyour rotor and centrifuge. A rotor inspection is included<strong>with</strong>in the other services on this page for one rotor whilethis service is made available for additional rotors youmay have.3 | Service | CentrifugationCertification for: Catalog No. List USDNON-Refrigerated Centrifuge 901510725 $300.00Refrigerated Centrifuge 901510723 350.00Rotor inspection for: Catalog No. List USDFixed-angle rotors 901510693 $85.00Swing-bucket rotors 901510695 85.00<strong>In</strong> the U.S.: <strong>Eppendorf</strong> North America 800-645-3050 · <strong>In</strong> Canada: <strong>Eppendorf</strong> Canada Ltd. 800-263-8715E-mail: info@eppendorf.com · www.eppendorf.com


Support and Services DirectoryContact <strong>In</strong>formationUnited StatesCanadaBusiness Hours: 8:30 a.m. to 6:00 p.m. EST 8:30 a.m. to 5:00 p.m. ESTPhone: 800-645-3050516-334-7500800-263-8715905-826-5525Fax: 516-334-7506 905-826-5424Address:<strong>Eppendorf</strong> North America, <strong>In</strong>c.102 Motor ParkwayHauppauge, NY 11788-5178<strong>Eppendorf</strong> Canada Ltd.2810 Argentia RoadUnit #2Mississauga, ONT L5N 8L2Website: www.eppendorfna.com www.eppendorf.caEmail: info@eppendorf.com canada@eppendorf.comCustomer Support: 800-645-3050, menu option 1custserv@eppendorf.com800-263-8715, menu option 1canadacustserv@eppendorf.comTechnical Service: 800-645-3050, menu option 2techserv@eppendorf.com800-263-8715, ext. 3231canadaservice@eppendorf.com800-645-3050, menu option 2techserv@eppendorf.comwww.eppendorf.com • Email: info@eppendorf.com<strong>In</strong> the U.S.: <strong>Eppendorf</strong> North America, <strong>In</strong>c. 800-645-3050 • <strong>In</strong> Canada: <strong>Eppendorf</strong> Canada Ltd. 800-263-8715