• Digital signal processing makes the <strong>MSLC</strong> resistantto power line distortions <strong>and</strong> harmonics• Digital communications across the LON reducesusceptibility to noise on the load sharing lines• Three-phase true RMS power sensing makes the<strong>MSLC</strong> accurate even with unbalanced phase loading<strong>and</strong> voltage fluctuations• Local Area Network carries plant parameters for usein a distributed control systemOPERATING MODESSynchronizing—The <strong>MSLC</strong> controls all DSLC-equippedgenerators to match both frequency <strong>and</strong> voltage betweenthe local bus <strong>and</strong> the main, <strong>and</strong> then closes the utility tiebreaker when they are synchronized.Base <strong>Load</strong>—The <strong>MSLC</strong> talks over its LON to set allDSLC-equipped generators in isochronous load sharing toa chosen percentage of their individual rated loads <strong>and</strong>power factor.Import/Export <strong>Control</strong>—The<strong>MSLC</strong> controls real load <strong>and</strong>reactive power across theutility tie. Real load (kW) iscontrolled by changing theload levels; reactive load(kVAR) is controlled bychanging the power factorreference on all DSLCequippedsystem generatorswhich are in isochronous loadsharing.Process <strong>Control</strong>—The<strong>MSLC</strong> control adjusts thereal load on the plantgenerators to maintain aprocess at a chosen level.ADJUSTMENTSThe Woodward H<strong>and</strong> Held Programmer makes alladjustments quickly <strong>and</strong> easily through the control’s tenconvenient menus. The control saves all set points inpermanent memory, which does not require batteries orother power sources to retain data. The H<strong>and</strong> HeldProgrammer prevents tampering with set points, yetallows entries to be changed at any time. The H<strong>and</strong> HeldProgrammer displays in plain English, so there are nocodes to look up or memorize.• Menu 1–<strong>Synchronizer</strong>• Menu 2–<strong>Load</strong> <strong>Control</strong>• Menu 3–<strong>Load</strong> Limits <strong>and</strong> Switches• Menu 4–Process <strong>Control</strong>• Menu 5–Configuration• Menu 6–Calibration• Menu 7–Electric Parameters• Menu 8–<strong>Control</strong> Status Monitor• Menu 9–Discrete Inputs/Outputs• Menu 0–DiagnosticsTypical Wiring Connections


SPECIFICATIONSEnvironmental SpecificationsOperating Temperature.....................................................–40 to +70 °C (–40 to +158 °F)Storage Temperature ........................................................–55 to +105 °C (–67 to +221 °F)Humidity...............................................................................95% at 38 °CElectromagnetic Susceptibility.........................................ANSI/IEEE C37.90.2; ANSI C37.90.1-1989Mechanical Shock ..............................................................US MIL-STD 810C, Method 516.2, Procedures I, II, VVibration ...............................................................................US MIL-STD 167, Type IElectrical Specifications<strong>Control</strong> Power Supply InputOperating .............................................................................8–32 Vdc continuous (as low as 10 Vdc, 1.8 A max, or as high as 77 Vdc for upto 5 min)Reverse................................................................................–56 Vdc continuousBurden..................................................................................18 W, 1 A maximumVoltage Sensing Inputs120 Vac Input (L-N) Wye PT Configuration....................65–150 Vac, terminals 4–5, 7–12, 9–12, <strong>and</strong> 11–12240 Vac Input (L-N) Wye PT Configuration....................150–300 Vac, terminals 3–5, 6–12, 8–12, <strong>and</strong> 10–12120 Vac Open Delta PT Configuration ...........................65–150 Vac, terminals 3–5, 6–8, 8–10, <strong>and</strong> 10–6240 Vac Open Delta PT Configuration ...........................150–300 Vac, terminals 3–5, 6–8, 8–10, <strong>and</strong> 10–6Phases .................................................................................Three phase utility bus, single phase generator busFrequency............................................................................45–66 HzBurden..................................................................................Less than 0.1 VA per phaseAccuracy...............................................................................0.1% of full scaleCurrent Transformer Inputs (CTs)Current..................................................................................0–5 Arms, 7 Arms max.Frequency............................................................................56 to 66 HzBurden..................................................................................Less than 0.1 VA per phaseAccuracy...............................................................................0.1% of full scalePhases .................................................................................Three phase utility busDiscrete Inputs ...................................................................18–40 Vdc @ 10 mAAnalog Inputs ......................................................................4–20 mA @ 243 A or 1-5 Vdc @ 10 kAAnalog Outputs ...................................................................Speed Bias: ±2.5 Vdc, 0.5–4.5 Vdc, 1–5 Vdc across 243 A, or 500 Hz PWMVoltage Bias: high in ±9 Vdc, low in ±3 Vdc, current 50 mARelay Driver Outputs ..........................................................18–40 Vdc @ 200 mA sinkLocal Area Network ...........................................................Echelon® LonWorks Technology, St<strong>and</strong>ard Protocol, 1.25 MBPSCalibration <strong>and</strong> Diagnostics Port ...................................RS-422ComplianceUL/cUL..................................................................................Listed<strong>MSLC</strong>PartVersionNumberWye, 120 or 240 Vac 9907-004Open delta, 120 Vac 9907-005Open delta, 240 Vac 9907-006<strong>MSLC</strong>/DSLC H<strong>and</strong> Held Programmer 9907-205


PO Box 15191000 East Drake RoadFort Collins CO, USA80522-1519Ph: (1)(970) 482-5811Fax: (1)(970) 498-3058www.woodward.comPlants & SubsidiariesAustralia (New South Wales)Brazil (Campinas)China (Tianjin)Germany (Aken/Elbe)India (Haryana)Japan (Tomisato & Kobe)Netherl<strong>and</strong>s (Hoofddorp &Rotterdam)SingaporeUK (Reading, Engl<strong>and</strong>, &Prestwick, Scotl<strong>and</strong>)US (Colorado, Illinois,Michigan, New York, SouthCarolina, Tennessee)Branch/Regional OfficesChina (Beijing)Czech Republic (Plzen)Germany (Tettnang)Korea (Pusan)Mexico (Mexico City)New Zeal<strong>and</strong> (Christchurch)Pol<strong>and</strong> (Warsaw)UAE (Abu Dhabi)UK (Dundee, Scotl<strong>and</strong>)US (Alabama, California,Illinois, Pennsylvania,Texas, Washington)<strong>MSLC</strong> Outline DrawingDistributors & ServiceWoodward has aninternational network ofdistributors <strong>and</strong> servicefacilities. For your nearestrepresentative call(1)(800) 835-5182 or see theWorldwide Directory on ourweb site (www.woodward.com).CORPORATEHEADQUARTERSRockford IL, USAPh: (1)(815) 877-7441This document is distributed forinformational purposes only. It isnot to be construed as creating orbecoming part of any WoodwardGovernor Company contractual orwarranty obligation unlessexpressly stated in a written salescontract.DSLC <strong>Control</strong> in a Parallel Bus/Utility Parallel Applicationwith an <strong>MSLC</strong> (<strong>Master</strong> <strong>Synchronizer</strong> <strong>and</strong> <strong>Load</strong> <strong>Control</strong>)For more information contact:© Woodward GovernorCompany, 1993All Rights Reserved99/7/F

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!