13.07.2015 Views

Equipment - Hanes Supply, Inc

Equipment - Hanes Supply, Inc

Equipment - Hanes Supply, Inc

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Buffalo - Headquarters: 716.826.2636 FAX: 716.826.4412Albany/NE Division: 518.438.0139 FAX: 518.438.5343Rochester Division: 585.235.0160 FAX: 585.235.0229Estimating the space to be heated:The following formula is used to determine the BTU’s needed to heat abuilding. This calculation would be for an average uninsulated building.Add more BTU’s if the building will have a great deal of heat loss openwindows and weather doors and reduce the BTU’s if the building is wellinsulated and weather tight.CUBIC FEET TOBE HEATEDUniversalDESIREDX .133 X =TEMPERATURE RISE• CUBIC FEET TO BE HEATED- Multiply the length times the width timesthe height of the area to be heated• DESIRED TEMPERATURE RISE- Subtract the lowest expected outsidetemperature from the desired inside temperatureEXAMPLE:A concrete block building 50 feet wide by 200 feet long with 20 feet from thefloor to the ceiling.All window and door openings are temporarily covered with plastic.The outside temperature is 15 degrees and we want the inside temperature tobe 55 degrees.Cubic Feet = 50 x 200 x 20- 200,000 cubic feetTemperature Rise = 55 - 15 = 40 degreesBTU’s Needed: 200,000 x .133 x 40 = 1,064,000 BTU’s per hourHeaters Needed: Four 250,000 BTU Convection Heaters or Three 375,000 BTUForced Air heaters will heat this job.ALWAYS VENTILATE THE HEATING AREAUniversalBTU’S/HOUR<strong>Hanes</strong> <strong>Supply</strong> of SC, <strong>Inc</strong>.CCISCO: 843.238.1338FAX: 843.238.8337<strong>Equipment</strong>Model 80-FAC(80,000 BTU/HR) Forced Air HeaterAutomatic solid state ignition, over temperaturelimiting switch, high velocity fanand many more safety and performancefeatures. Can be operated with accessorythermostat (#6184) for maximum fuel savings and uniform temperaturecontrol. Ideal for medium size jobs up to 15,000 cu. ft. Recommended foruse with 40 lb. or larger propane tank. AGA & CGA Certified.Model 85-FAC(adjustable 50,000 to 85,000 BTU/HR)Forced Air HeaterFeatures continuous electronic ignition andadjustable heat output from 50,000 to85,000 BTU/HR for buildings from 9,000 to16,000 cu. ft. High output fan for better distributionof heated air. Ignition will not take place unless heater is pluggedin. Propane flow stops if heater is accidentally unplugged. Can be operatedfor hours (at low setting) from a standard 20 lb. tank. Powder coatedfinish. Patent #5,553,220/AGA & CGA Certified.Model 125-FAC(adjustable 75,000 to 125,000 BTU/HR)Forced Air HeaterSimilar to the 85-FAC, but with higherheating output. Adjustable from 75,000to 125,000 BTU/HR and heats from 14,000to 24,000 cu. ft. Ignition will not take placeunless heater is plugged in. Can be operated for hours (at low setting)from a 40 lb. or larger propane tank. Powder coated finish. Patent #5,553,220 AGA & CGA Certified.PROPANE & NATURAL GAS FORCED AIRModel 30-FAS(30,000 BTU/HR) Blower Type Forced AirHeaterIdeal for shops, work areas, farm, ranch andcraftsmen. Features push button electronicignition, stainless steel burner, high performancesquirrel cage blower. Compact boxdesign heats up to 5,000 cu.ft. of space.Ignition will not take place unless heater isplugged in. Propane flow stops if heater isaccidentally unplugged. Operates for hoursfrom a standard 20 lb. propane tank. Powdercoated finish. Patent No. 4,848,313. AGA & CGA Certified.Model 35-FAC(35,000 BTU/HR) Forced Air HeaterEconomy model - low cost - high heat output.Keeps shops and work areas of up to6,000 cu. ft. comfortable in the coldestweather. Push button piezoelectric ignitionstandard. Light weight, compact and operatesfor hours from a standard 20 lb propane tank.Aluminized steel finish. Certification Pending.Model 45-FAC(adjustable 25,000 to 45,000 BTU/HR)Forced Air HeaterThis adjustable heater is designed for heatoutput from 25,000 to 45,000 BTU/HR anda range of heating space from 4,000 to8,000 cu. ft. Automatic electronic ignition. Propane flow stops if heateris accidentally unplugged. Can operate for hours from a standard 20 lb.propane tank. Powder coated finish. Patent # 5,553,220/AGA & CGACertified.Model 150-FAST(150,000 BTU/HR) Forced Air Heater with ThermostatThis high output heater is designed for big jobs. Lightweight and featuresautomatic ignition. This unit has a built in thermostat for most economicaloperation. Heats up to 29,000 cu. ft. Operates from one or more 100 lb.propane tanks. Powder coated finish.AGA & CGA Certified.Model 150-FANG(150,000 BTU/HR) Natural Gas FueledForced Air HeaterSimilar to 150-FAST, but designed tooperate on natural gas. Does not include built-in thermostat. <strong>Inc</strong>ludes 4"WC regulator. Does not include hose. AGA & CGA Certified.Model 3500-FACV(adjustable 175,000 to 350,000 BTU/HR) Forced Air Heater withThermostatFor the big heating jobs. Commercial, industrial, warehouse, constructionand agriculture. Heating output can be adjusted from 175,000 to 350,000BTU/HR to meet the job requirement and a built-in thermostat offers mosteconomical operation. Heats in a range of 34,000 up to 69,000 cu. ft. Thelong life “Starfire” ® ceramic burner offers quiet operation and better mixingand distribution of heated air. Recommended for use with two or more 100lb. propane cylinders. Powder coated finish. Patents #5,017,129 and#5,553,220. AGA & CGA Certified.Model 3500-FACNG(adjustable to 175,000 to 350,000BTU/HR) Natural Gas Fueled ForcedAir Heater with Thermostat)Similar to 3500-FACV, but designed tooperate from a minimum of 15 PSIGhigh pressure natural gas. <strong>Inc</strong>ludes 5 - 20 PSIG regulator.Does not include hose. Patent #5,017,129.30WWW.HANESSUPPLY.COM30-37<strong>Equipment</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!