13.07.2015 Views

SINAMICS drives - Siemens

SINAMICS drives - Siemens

SINAMICS drives - Siemens

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Technical specifications power modules for the <strong>SINAMICS</strong> G120PM240 FS A-F (400 V)UnfilteredPM240 FS B-F (400 V)FilteredPM250 FS C-F (400 V)FilteredPM260 FS D-F (690 V)Filtered/UnfilteredSelection characteristicsPower output0.37–110 kW(for high overload - HO)0.37–132 kW(for low overload - LO)2.2–75 kW (HO)2.2–90 kW (LO)5.5–75 kW(for high overload – HO)7.5–90 kW(for low overload – LO)7,5–37 kW(for high overload – HO)11–55 kW(for low overload – LO)Rated input current (at ambient 1.7–204 A 7.6–204 A 13.2–135 A 12–46 Atemperature of 50 °C) 2Rated output current (at ambienttemperature of 50 °C)1.3–210 A (HO)1.3–250 A (LO)1.3–145 A (HO)1.3–178 A (LO)13.2–145 A (HO)18–178 A (LO)10–42 A (HO)14–62 A (LO)Mounting dimensions (W x H x D)in mm (information for PM:dimensions PM and CU)A: 73 x 173 x 210B: 153 x 270 x 230C: 189 x 334 x 250D: 275 x 419 x 260E: 275 x 499 x 260F: 350 x 634 x 372–B: 153 x 270 x 230C: 189 x 334 x 250D: 275 x 512 x 260E: 275 x 635 x 260F: 350 x 934 x 372––C: 189 x 334 x 250D: 275 x 512 x 260E: 275 x 635 x 260F: 350 x 934 x 372–––D: 275 x 512 x 260–F: 350 x 634 x 372Safety functionsIntegrated safety functions in accor d-ance with Category 3 of EN 954-1 orin accordance with SIL 2 of IEC 61508Safe Brake Control (SBC)Electrical dataLine voltage 3 AC 380 ... 480 V ± 10% 3 AC 380 ... 480 V ± 10% 3 AC 380 ... 480 V ± 10% 3 AC 660 … 690 V ± 10% 3Line frequency 47–63 Hz 47–63 Hz 47–63 Hz 47–63 HzOverload capability(in the event of high overload)0.37–75 kW:1.5 x rated current for 1 minwithin 5 min2 x rated current for 3 swithin 5 min1.5 x rated current for 1 min within 5 min2 x rated current for 3 s within 5 min90–110 kW:1.36 x rated current for 1 minwithin 5 min1.6 x rated current for 3 swithin 5 minOverload capability(in the event of light overload)0.37–90 kW:1.1 x rated current for 1 minwithin 5 min1.5 x rated current for 3 swithin 5 min1.1 x rated current for 1 min within 5 min1.5 x rated current for 3 s within 5 min110–132 kW:1.1 x rated current for 1 minwithin 5 min1.5 x rated current for 1 swithin 5 minOutput frequency0–650 Hz(U/f and FCC types of control)0–200 Hz(Vector type of control)0–650 Hz(U/f and FCC types of control)0–200 Hz(Vector type of control)0–650 Hz(U/f and FCC types of control)0–200 Hz(Vector type of control)0–200 HzPulse frequency4 kHz (standard),or 4–16 kHz in steps of 2 kHz (derating)C–E: 4 kHz (standard) or 4–16 kHzin steps of 2 kHz (derating)F: 4 kHz (standard) or 4–8 kHz insteps of 2 kHz (derating)16 kHz (standard)Converter efficiency 96–97 % 96–97 % 95–97 % 95–97 %FunctionsBraking functionsMechanical dataDynamic braking, DC braking, electromechanical braking,motor holding braking, instant braking, electronic braking,compound brakingEnergy recovery in regenerative modeDegree of protection IP20 IP20 IP20 IP20SoftwareSTARTER x x x x2The input current depends on the motor load and line impedance3500 to 600 V possible with derating11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!