Quick Coupling Products - LSR Distribuidor
Quick Coupling Products - LSR Distribuidor Quick Coupling Products - LSR Distribuidor
Pneumatic Quick CouplingsNipplesFemale Pipe ThreadDEFGGeneral Purpose – Manual Connect10 SeriesBody Part Part Thread Dimensions (in.)Size No. No. Size Overall Exposed Hex Largest Wt. (LB)(in.) Brass Steel NPTF Length Length* Size Diameter P/PieceD E F G1/4 – 1C 1/8-27 1.28 0.55 0.50 0.58 0.051/4 B3C 3C 1/4-18 1.47 0.74 0.62 0.72 0.051/4 – 3C-E 3/8-18 1.50 0.77 0.81 0.94 0.073/8 – 1E 1/4-18 1.60 0.67 0.62 0.72 0.073/8 – 3E 3/8-18 1.68 0.77 0.81 0.94 0.101/2 – 1F 3/8-18 2.05 0.83 0.81 0.94 0.131/2 – 3F 1/2-14 2.27 1.05 1.00 1.16 0.181/2 – H3F-G 3/4-14 2.38 1.13 1.25 1.44 0.26A PneumaticsMale Pipe ThreadDEFG* This dimension represents portion of nipple that is exposed when nipple is inserted in a Parker 10 Series coupler.Body Part Part Part No. Thread Dimensions (in.)Size No. No. Type 303 Size Overall Exposed Hex Largest Wt. (LB)(in.) Brass Steel Stainless NPTF Length Length* Size Diameter P/PieceD E F G1/4 – 0C – 1/8-27 1.47 0.74 0.50 0.58 0.041/4 B2C 2C S2C 1/4-18 1.62 0.89 0.56 0.65 0.061/4 – 2C-E – 3/8-18 1.72 0.99 0.69 0.80 0.053/8 – 0E – 1/4-18 1.88 0.95 0.62 0.72 0.083/8 – 2E – 3/8-18 1.90 0.98 0.69 0.80 0.091/2 – 0F – 3/8-18 2.33 1.12 0.69 0.79 0.131/2 – 2F – 1/2-14 2.48 1.27 0.88 1.01 0.171/2 – H2F-G – 3/4-14 2.53 1.29 1.13 1.30 0.24* This dimension represents portion of nipple that is exposed when nipple is inserted in a Parker 10 Series coupler.Standard Hose BarbDEPush-Lok Hose Barb**DEGGBody Part Dimensions (in.)Size No. Hose Overall Exposed Largest Wt. (LB)(in.) Steel I.D. Length Length* Diameter P/PieceD E G1/4 8C 1/4 1.63 .090 0.45 0.041/4 9C 3/8 2.00 1.27 0.55 0.053/8 5E 3/8 1.81 0.89 0.59 0.071/2 H4F 3/8 2.53 1.29 0.69 0.081/2 5F 1/2 2.81 1.60 0.81 0.111/2 H5F-G 3/4 3.16 1.91 0.94 0.18* This dimension represents portion of nipple that is exposed when nipple is inserted in a Parker 10 Series coupler.Body Part Dimensions (in.)Size No. Hose Overall Exposed Largest Wt. (LB)(in.) Steel I.D. Length Length* Diameter P/PieceD E G1/4 8CP 1/4 1.66 0.93 0.45 0.041/4 9CP 3/8 1.98 1.25 0.86 0.053/8 5EP 3/8 1.98 1.06 0.59 0.081/2 H4FP 3/8 2.52 1.27 0.86 0.111/2 H5FP 1/2 2.66 1.42 0.97 0.11* This dimension represents portion of nipple that is exposed when nipple is inserted in a Parker 10 Series coupler.** Push-Lok hose barbs are designed for use with Parker Push-Lok hose and do not require clamps.A-11Quick Coupling Division8145 Lewis Road • Minneapolis, MN 55427www.parker.com/quickcouplings
A PneumaticsPneumatic Quick CouplingsFeatures• Parker 20 Series sleeve type couplers accept industrialinterchange nipples manufactured by Parker and othermanufacturers.• Standard seals are Nitrile. See the Coupling Selection andOrdering Information Guide at the beginning of Section Aand the Fluid Compatibility Chart at the end of this catalogfor optional materials.SpecificationsGeneral Purpose – Manual Connect20 Series Industrial InterchangeHow to Order InformationThe standard 1/4" 20 Series is a brass coupler with a steelvalve. The larger sizes are an all steel construction with brassavailable as an option. To order a 3/8" or 1/2" body sizecoupler with a brass body and a steel sleeve and valve, addthe prefix “B” to the steel part number. Example: B16.Add the suffix “N” as well as the “B” prefix to order an allbrass coupler with stainless steel locking balls and springs,Example: B25N. All-brass couplings should be used to avoidcorrosion from moisture. Consult factory for specificrecommendations.Available with Sleeve-Lok (See Coupler Options at thebeginning of Section A). To order, add “-SL” as a suffix to thepart number, Example: 25-SL.Available for 1/4" 20 Series couplers is a Grip-Ring sleeve(See Coupler Options). To order, add the suffix “R” to the partnumber, Example: B23R.ApplicationsSleeve type couplings are widely used to connect air linesand can also be used with low pressure fluids.Their compact and economical design uses a ball lockingmechanism consisting of captive steel balls that engage thelocking groove on the mating nipple. The sliding spring loadedsleeve on the coupler must be manually retracted in order toconnect or disconnect the nipple. It is easy to do, but twohands are normally required.Common applications include: compressed air, water, grease,paint, limited vacuum and limited gases.Body Size (in.) 1/4 3/8 1/2Rated Pressure (psi) 300 300 300Temperature Range (Std. seals)* -40° to +250° F.Locking Device 4 balls 8 balls 8 ballsVacuum Data (inches Hg)Disconnected (coupler only)Not recommendedConnected 27.4 27.4 27.4* See Coupling Selection and Ordering Guide for Optional SealsSee Coupling Repair Kits Table on introduction page to GeneralPurpose - Manual Connect CouplersPerformanceAir Flow in SCFM1601401201008060402020 Series (1/4", 3/8", 1/2" sizes)1/2"3/8"1/4"00 5 10 15 20Pressure Drop in PSID100 PSI Inlet Pressure80 PSI Inlet PressureA-12Quick Coupling Division8145 Lewis Road • Minneapolis, MN 55427www.parker.com/quickcouplings
- Page 1: Quick CouplingProductsCatalog 3800
- Page 5: A PneumaticsPneumatic Quick Couplin
- Page 11 and 12: A PneumaticsPneumatic Quick Couplin
- Page 13: A PneumaticsPneumatic Quick Couplin
- Page 17 and 18: A PneumaticsPneumatic Quick Couplin
- Page 20 and 21: Pneumatic Quick Couplings3General P
- Page 22 and 23: Pneumatic Quick CouplingsCouplersFe
- Page 24 and 25: Pneumatic Quick CouplingsGeneral Pu
- Page 26 and 27: Pneumatic Quick Couplings1/4" and 3
- Page 28 and 29: Pneumatic Quick CouplingsGeneral Pu
- Page 30 and 31: Pneumatic Quick Couplings7General P
- Page 32 and 33: Pneumatic Quick CouplingsCouplersFe
- Page 34 and 35: Pneumatic Quick CouplingsGeneral Pu
- Page 36 and 37: Pneumatic Quick CouplingsSpecial Pu
- Page 38 and 39: Pneumatic Quick CouplingsSpecial Pu
- Page 40 and 41: Pneumatic Quick CouplingsOperationP
- Page 42 and 43: Pneumatic Quick CouplingsSpecial Pu
- Page 44 and 45: Pneumatic Quick CouplingsMale Reusa
- Page 46 and 47: Pneumatic Quick CouplingsPartMeets
- Page 48 and 49: HydraulicB HydraulicsQuickCouplings
- Page 50 and 51: Hydraulic Quick CouplingsTable of C
- Page 52 and 53: Hydraulic Quick CouplingsGeneral Pu
- Page 54 and 55: Hydraulic Quick CouplingsGeneral Pu
- Page 56 and 57: Hydraulic Quick CouplingsGeneral Pu
- Page 58 and 59: Hydraulic Quick CouplingsGeneral Pu
- Page 60 and 61: Hydraulic Quick CouplingsGeneral Pu
- Page 62 and 63: Hydraulic Quick CouplingsGeneral Pu
Pneumatic <strong>Quick</strong> <strong>Coupling</strong>sNipplesFemale Pipe ThreadDEFGGeneral Purpose – Manual Connect10 SeriesBody Part Part Thread Dimensions (in.)Size No. No. Size Overall Exposed Hex Largest Wt. (LB)(in.) Brass Steel NPTF Length Length* Size Diameter P/PieceD E F G1/4 – 1C 1/8-27 1.28 0.55 0.50 0.58 0.051/4 B3C 3C 1/4-18 1.47 0.74 0.62 0.72 0.051/4 – 3C-E 3/8-18 1.50 0.77 0.81 0.94 0.073/8 – 1E 1/4-18 1.60 0.67 0.62 0.72 0.073/8 – 3E 3/8-18 1.68 0.77 0.81 0.94 0.101/2 – 1F 3/8-18 2.05 0.83 0.81 0.94 0.131/2 – 3F 1/2-14 2.27 1.05 1.00 1.16 0.181/2 – H3F-G 3/4-14 2.38 1.13 1.25 1.44 0.26A PneumaticsMale Pipe ThreadDEFG* This dimension represents portion of nipple that is exposed when nipple is inserted in a Parker 10 Series coupler.Body Part Part Part No. Thread Dimensions (in.)Size No. No. Type 303 Size Overall Exposed Hex Largest Wt. (LB)(in.) Brass Steel Stainless NPTF Length Length* Size Diameter P/PieceD E F G1/4 – 0C – 1/8-27 1.47 0.74 0.50 0.58 0.041/4 B2C 2C S2C 1/4-18 1.62 0.89 0.56 0.65 0.061/4 – 2C-E – 3/8-18 1.72 0.99 0.69 0.80 0.053/8 – 0E – 1/4-18 1.88 0.95 0.62 0.72 0.083/8 – 2E – 3/8-18 1.90 0.98 0.69 0.80 0.091/2 – 0F – 3/8-18 2.33 1.12 0.69 0.79 0.131/2 – 2F – 1/2-14 2.48 1.27 0.88 1.01 0.171/2 – H2F-G – 3/4-14 2.53 1.29 1.13 1.30 0.24* This dimension represents portion of nipple that is exposed when nipple is inserted in a Parker 10 Series coupler.Standard Hose BarbDEPush-Lok Hose Barb**DEGGBody Part Dimensions (in.)Size No. Hose Overall Exposed Largest Wt. (LB)(in.) Steel I.D. Length Length* Diameter P/PieceD E G1/4 8C 1/4 1.63 .090 0.45 0.041/4 9C 3/8 2.00 1.27 0.55 0.053/8 5E 3/8 1.81 0.89 0.59 0.071/2 H4F 3/8 2.53 1.29 0.69 0.081/2 5F 1/2 2.81 1.60 0.81 0.111/2 H5F-G 3/4 3.16 1.91 0.94 0.18* This dimension represents portion of nipple that is exposed when nipple is inserted in a Parker 10 Series coupler.Body Part Dimensions (in.)Size No. Hose Overall Exposed Largest Wt. (LB)(in.) Steel I.D. Length Length* Diameter P/PieceD E G1/4 8CP 1/4 1.66 0.93 0.45 0.041/4 9CP 3/8 1.98 1.25 0.86 0.053/8 5EP 3/8 1.98 1.06 0.59 0.081/2 H4FP 3/8 2.52 1.27 0.86 0.111/2 H5FP 1/2 2.66 1.42 0.97 0.11* This dimension represents portion of nipple that is exposed when nipple is inserted in a Parker 10 Series coupler.** Push-Lok hose barbs are designed for use with Parker Push-Lok hose and do not require clamps.A-11<strong>Quick</strong> <strong>Coupling</strong> Division8145 Lewis Road • Minneapolis, MN 55427www.parker.com/quickcouplings