62 Sample Safety-Shutdown ProgramsInput ParametersThe table below describes the input parameters for the TR_SHUTDOWN function block.ParameterCIIO_COIO_TMRIO_GE_DUALIO_GE_SINGLEIO_NO_VOTER_FLTSIO_ERRORMAX_TIME_DUALMAX_TIME_SINGLEMAX_SCAN_TIMEDescriptionControl inIf CI is false, then CO is false—no change in the output valueIf CI is true and ERROR_NUM is 0, then CO is trueCritical I/O control outAll critical I/O points are operating in triple modular redundant modeAll critical I/O points are operating are operating in dual or TMR modeAll critical I/O points are operating are operating in single, dual, or TMR modeIf true, then no voter faults exist on a critical I/O moduleIf false, then a voter fault exists on a critical I/O moduleError number—zero indicates no error. Non-zero indicates a programming orconfiguration errorMaximum time with only two channels operatingMaximum time with only one channel operating50% of the maximum response timeTricon Safety Considerations Guide

Sample Safety-Shutdown Programs 63Output ParametersThe table below describes the output parameters for the TR_SHUTDOWN function block.ParameterCOOPERATINGTMRDUALSINGLZEROTIMER_RUNNINGTIME_LEFTALARM_PROGRAMMING_PERMITTEDALARM_REMOTE_ACCESSALARM_RESPONSE_TIMEALARM_DISABLED_POINTSERROR_NUMDescriptionControl outWhen OPERATING is true, all safety-critical modules areoperating properlyWhen OPERATING is false, the time in degraded operationexceeds the specified limits; therefore, the control programshould shut down the processSystem is operating in triple modular redundant modeAt least one safety-critical point is controlled by two channelsAt least one safety-critical point is controlled by one channelAt least one safety-critical point is not controlled by anychannelTime left to shutdown is decreasingTime remaining before shutdownTrue if application changes are permittedTrue if remote-host writes are enabledTrue if actual scan time is greater than MAX_SCAN_TIMETrue if one or more points are disabledError Number:0 = No error1 = Error in maximum time2 = I/O function block error—IO_ERROR is non-zero3 = Function block error—system status or MP StatusChapter 4Application Development

62 Sample <strong>Safety</strong>-Shutdown ProgramsInput ParametersThe table below describes the input parameters for the TR_SHUTDOWN function block.ParameterCIIO_COIO_TMRIO_GE_DUALIO_GE_SINGLEIO_NO_VOTER_FLTSIO_ERRORMAX_TIME_DUALMAX_TIME_SINGLEMAX_SCAN_TIMEDescriptionControl inIf CI is false, then CO is false—no change in the output valueIf CI is true and ERROR_NUM is 0, then CO is trueCritical I/O control outAll critical I/O points are operating in triple modular redundant modeAll critical I/O points are operating are operating in dual or TMR modeAll critical I/O points are operating are operating in single, dual, or TMR modeIf true, then no voter faults exist on a critical I/O moduleIf false, then a voter fault exists on a critical I/O moduleError number—zero indicates no error. Non-zero indicates a programming orconfiguration errorMaximum time with only two channels operatingMaximum time with only one channel operating50% of the maximum response time<strong>Tricon</strong> <strong>Safety</strong> <strong>Considerations</strong> <strong>Guide</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!