13.07.2015 Views

Safety Considerations Guide, Tricon v9.0 - Tuv-fs.com

Safety Considerations Guide, Tricon v9.0 - Tuv-fs.com

Safety Considerations Guide, Tricon v9.0 - Tuv-fs.com

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Guide</strong>lines for <strong>Tricon</strong> Controllers 29SIL3/AK6 <strong>Guide</strong>linesFor SIL3/ AK6 applications, the following guidelines should be followed:• DIN V VDE 19250/AK6 applications that require continued operation afterdetecting an output failure must have a secondary means of operating theoutput. A secondary means may be an external group relay or a single pointon an independent output module that controls a group of outputs. If a relayis used, it should be checked at least every six months, manually orautomatically.• If non-approved modules are used, the inputs and outputs should be checkedto verify that they do not affect safety-critical functions of the controller.• Two modes control write operations from external hosts:– Remote Mode—When the keyswitch setting is REMOTE, externalhosts, such as Modbus master, DCS, etc., can write aliased data in thecontroller. When false, writes are prohibited.– Program Mode—When the keyswitch setting is PROGRAM, TriStationcan make program changes, including operations that modify thebehavior of the programs currently running. (For example, DownloadAll, Download Change, declaring variables, enabling/disablingvariables, changing values of variables and scan time, etc.)Remote mode and program mode are independent of each other. In safetyapplication, operation in these modes is not re<strong>com</strong>mended. In other words,write operations to the controller from external hosts should be prohibited. Ifremote mode or program mode be<strong>com</strong>es true, the application programshould include the following safeguards:– When remote mode is true:• A program should turn on an alarm. For example, if using theTR_SHUTDOWN function block, the ALARM_REMOTE_ACCESSoutput could be used.• Aliased variables should be checked for adherence to the guidelinesdescribed in section “Maintenance Overrides” on page 32.– When program mode is true:• A program should turn on an alarm. For example, if using theTR_SHUTDOWN function block, theALARM_PROGRAMMING_PERMITTED output could be used.• Wiring and grounding procedures outlined in the <strong>Tricon</strong> Planning &Installation <strong>Guide</strong> should be followed.Chapter 2Application <strong>Guide</strong>lines

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!