13.07.2015 Views

M and F Line - HVAC and Refrigeration Information Links

M and F Line - HVAC and Refrigeration Information Links

M and F Line - HVAC and Refrigeration Information Links

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SystemPro ® air-cooled condensing unitsCapacity DataHIGH/MED TEMPCapacity (BTU/Hr) at 110° Ambient - Evaporator Temp (°F)Model BOM Refrig. H.P. 0 +10 +15 +20 +25M2FH-0017-SAA 111 134a 1/6 660 760 840 950M2FH-0020-IAA 111 134a 1/5 820 930 1040 1170MMFH-0022-IAA 111 22 1/5 1050 1170 1300 1440M4FH-0022-IAA 111 404A 1/5 1130 1230 1350 1480M2FH-0024-SAA 111 134a 1/4 1140 1290 1420 1590M2FH-0026-IAA 072,111,103 134a 1/4 1330 1470 1570 1740MCFH-0027-IAA 111,103,272 22 1/4 1540 1750 1970 2180M4FH-0025-IAA 103,272 404A 1/4 1530 1690 1840 2020M2FH-A033-IAA, IAV 111,103,272 134a 1/3 1520 1740 1970 2220MCFH-0036-IAA 111,103,272 22 1/3 1880 2120 2370 2640M4FH-A036-IAA, IAV 111,103,272 404A 1/3 2110 2340 2590 2840M2FH-0049-IAA, IAV 111,103,272 134a 1/2 2210 2490 2790 3100MCFH-0049-CAA, CAV 111,103,272 22 1/2 2690 3020 3370 3750M2FH-0050-IAA-IAV 111,103,272 134a 1/2 2470 2890 3210 3560M4FF-0050-IAA, IAV 212 404A 1/2 2320 2860 3110 3370M4FF-0056-IAA, IAV 103,212,272 404A 1/2 2430 3070 3400 3750 4100M2FH-0056-IAA, IAV 111,103,272 134a 1/2 2750 3120 3520 3870MCFH-0056-IAA, IAV 111,103,272 22 1/2 2960 3320 3710 4130M4FH-0050-CAA, CAV 111,103,272 404A 1/2 2660 2940 3240 3530FTAH-B074-IAA, IAV 212 134a 3/4 3030 3450 3880 4350FTAM-A075-IAA, IAV 020 134a 3/4 3520 3940 4460 5070F3AH-A078-IAA, IAV 020 22 3/4 3540 4100 4660 5270M4FF-0075-CAA, CAV 020 404A 3/4 3120 3960 4400 4850 5310FTAH-A101-CFV, TFC, TFD 020 134a 1 3680 4450 5310 6160F3AH-A100-CAV 020 22 1 4230 4870 5520 6210FJAF-0106-CAV 020 404A 1 4120 5150 5700 6270 6860F3AM-A105-CFV, TFC 020 22 1 3050 4940 5830 6720 7670FTAH-A125-CFV, TFC, TFD 020 134a 1-1/4 5230 6330 7500 8750FJAM-A125-CFV, TFC 020 404A 1-1/4 4070 5230 5820 6440 7100FJAM-A126-CAV, TFC 020 404A 1-1/4 4850 6150 6820 7530 8260FTAH-A150-CFV, TFC, TFD 020 134a 1-1/2 6220 7520 8900 10400FGAH-A151-CFV, TFC, TFD 020 22 1-1/2 5400 6470 7620 8850FGAH-A151-CFV, TFC, TFD 020 407C 1-1/2 6100 7120 8170 9270FJAM-A150-CFV, TFC, TFD 020 404A 1-1/2 4680 6520 7450 8380 9310FTAH-A201-CFV, TFC, TFD 020 134a 2 7480 9150 10900 12800FGAH-A201-CFV, TFC, TFD 015, 020 22 2 7780 9270 10800 12500FGAH-A201-CFV, TFC, TFD 015, 020 407C 2 7840 9190 10600 12000FJAM-A200-CFV, TFC 020 404A 2 6230 8530 9740 11000 12300FJAM-A225-CFV, TFC, TFD 020 404A 2-1/4 7730 10100 11300 12500 13700FGAH-A225-CFV, TFC, TFD 015, 020 22 2-1/4 8970 10500 12200 14000FGAH-A225-CFV, TFC, TFD 015, 020 407C 2-1/4 9120 10700 12300 14000FGAH-A301-CFV, TFC, TFD 015, 020 22 3 13100 15400 17800 20200FGAH-A301-CFV, TFC, TFD 015, 020 407C 3 10900 13100 15300 17600FJAM-A300-CFV, TFC, TFD 020 404A 3 9410 12800 14500 16300 18000FGAH-A325-CFV, TFC, TFD 015, 020 22 3-1/4 14800 17200 19600 22000FGAH-A325-CFV, TFC, TFD 015, 020 407C 3-1/4 11900 14300 16800 19300FJAM-A325-CFV, TFC, TFD 020 404A 3-1/4 10100 13500 15400 17500 19800FGAH-A401-CFV, TFC, TFD 015, 020 22 4 21100 24400 27800 31400FGAH-A401-CFV, TFC, TFD 015, 020 407C 4 16800 20300 23900 27700FJAM-B400-CFV, TFC, TFD 020 404A 4 15600 20500 23200 26100 29300FGAH-A501-CFV, TFC, TFD, TFE 015, 020 22 5 24900 28900 33000 37100FGAH-A501-CFV, TFC, TFD, TFE 015, 020 407C 5 24600 28500 32500 36600FJAM-B500-CFV, TFC 020 404A 5 17700 23600 26600 29500 32300Capacities are at 60 Hertz with 5°F subcooling.HT models are rated at 65°F return gas temperature.MT models are rated at 40°F return gas temperatureNOTE: See appendix for Flex-<strong>Line</strong> hood information2011DS-4 _M&F (4/11)6Emerson Climate Technologies

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!