SystemPro ® air-cooled condensing unitsCapacity DataHIGH/MED TEMPCapacity (BTU/Hr) at 100° Ambient - Evaporator Temp (°F)Model BOM Refrig. H.P. 0 +10 +15 +20 +25M2FH-0017-SAA 111 134a 1/6 730 830 930 1050M2FH-0020-IAA 111 134a 1/5 890 1010 1120 1250MMFH-0022-IAA 111 22 1/5 1140 1270 1400 1550M4FH-0022-IAA 111 404A 1/5 1230 1340 1460 1590M2FH-0024-SAA 111 134a 1/4 1230 1390 1530 1710M2FH-0026-IAA 072,111,103 134a 1/4 1400 1570 1710 1890MCFH-0027-IAA 111,103,272 22 1/4 1710 1930 2150 2380M4FH-0025-IAA 103,272 404A 1/4 1700 1870 2030 2220M2FH-A033-IAA, IAV 111,103,272 134a 1/3 1690 1920 2150 2420MCFH-0036-IAA 111,103,272 22 1/3 2080 2330 2600 2890M4FH-A036-IAA, IAV 111,103,272 404A 1/3 2330 2580 2840 3100M2FH-0049-IAA, IAV 111,103,272 134a 1/2 2410 2710 3020 3350MCFH-0049-CAA, CAV 111,103,272 22 1/2 2910 3260 3630 4010M2FH-0050-IAA-IAV 111,103,272 134a 1/2 2730 3170 3500 3860M4FF-0050-IAA, IAV 212 404A 1/2 2660 3260 3550 3850 4140M4FF-0056-IAA, IAV 103,212,272 404A 1/2 2780 3490 3860 4240 4630M2FH-0056-IAA, IAV 111,103,272 134a 1/2 3010 3430 3880 4220MCFH-0056-IAA, IAV 111,103,272 22 1/2 3270 3660 4070 4520M4FH-0050-CAA, CAV 111,103,272 404A 1/2 2900 3220 3560 3910FTAH-B074-IAA, IAV 212 134a 3/4 3420 3870 4350 4860FTAM-A075-IAA, IAV 020 134a 3/4 3870 4430 5070 5780F3AH-A078-IAA, IAV 020 22 3/4 4020 4620 5220 5860M4FF-0075-CAA, CAV 020 404A 3/4 3540 4470 4960 5460 5980FTAH-A101-CFV, TFC, TFD 020 134a 1 4330 5160 6060 6970F3AH-A100-CAV 020 22 1 4740 5440 6140 6910FJAF-0106-CAV 020 404A 1 4650 5800 6410 7040 7700F3AM-A105-CFV, TFC 020 22 1 5750 6700 7640 8650FTAH-A125-CFV, TFC, TFD 020 134a 1-1/4 6190 7360 8620 9970FJAM-A125-CFV, TFC 020 404A 1-1/4 4770 6070 6750 7470 8250FJAM-A126-CAV, TFC 020 404A 1-1/4 5610 7060 7810 8600 9420FTAH-A150-CFV, TFC, TFD 020 134a 1-1/2 7370 8760 10200 11800FGAH-A151-CFV, TFC, TFD 020 22 1-1/2 6490 7630 8850 10200FGAH-A151-CFV, TFC, TFD 020 407C 1-1/2 4810 6860 7940 9050 10200FJAM-A150-CFV, TFC, TFD 020 404A 1-1/2 5780 7820 8850 9890 10900FTAH-A201-CFV, TFC, TFD 020 134a 2 8880 10700 12600 14600FGAH-A201-CFV, TFC, TFD 015, 020 22 2 8930 10500 12200 13900FGAH-A201-CFV, TFC, TFD 015, 020 407C 2 6110 8820 10200 11700 13300FJAM-A200-CFV, TFC 020 404A 2 7500 10100 11400 12800 14200FJAM-A225-CFV, TFC, TFD 020 404A 2-1/4 9060 11700 13100 14500 15800FGAH-A225-CFV, TFC, TFD 015, 020 22 2-1/4 10100 11800 13600 15500FGAH-A225-CFV, TFC, TFD 015, 020 407C 2-1/4 7120 10300 11900 13600 15400FGAH-A301-CFV, TFC, TFD 015, 020 22 3 15100 17400 19900 22400 25000FGAH-A301-CFV, TFC, TFD 015, 020 407C 3 8360 12900 15200 17600 20100FJAM-A300-CFV, TFC, TFD 020 404A 3 11200 15000 17000 18900 20900FGAH-A325-CFV, TFC, TFD 015, 020 22 3-1/4 16500 19000 21600 24200FGAH-A325-CFV, TFC, TFD 015, 020 407C 3-1/4 9160 14200 16700 19300 22000FJAM-A325-CFV, TFC, TFD 020 404A 3-1/4 12200 16000 18100 20400 22900FGAH-A401-CFV, TFC, TFD 015, 020 22 4 23500 27000 30600 34500FGAH-A401-CFV, TFC, TFD 015, 020 407C 4 12700 19900 23600 27500 31500FJAM-B400-CFV, TFC, TFD 020 404A 4 18100 23700 26800 30000 33500FGAH-A501-CFV, TFC, TFD, TFE 015, 020 22 5 28000 32100 36300 40600FGAH-A501-CFV, TFC, TFD, TFE 015, 020 407C 5 27600 31600 35700 40000FJAM-B500-CFV, TFC 020 404A 5 20400 27000 30300 33600 36700Capacities are at 60 Hertz with 5°F subcooling.HT models are rated at 65°F return gas temperature.MT models are rated at 40°F return gas temperatureNOTE: See appendix for Flex-<strong>Line</strong> hood information2011DS-4 _M&F (4/11)4Emerson Climate Technologies

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!