13.07.2015 Views

210-MS, 220-MS, or 225-MS Ion Trap Mass Spectrometer Pre ...

210-MS, 220-MS, or 225-MS Ion Trap Mass Spectrometer Pre ...

210-MS, 220-MS, or 225-MS Ion Trap Mass Spectrometer Pre ...

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Ammonia, Anhydrous (CAS Number 7664-41-7)Anhydrous Ammonia gas is highly toxic. Inhalation may cause irritation to eyes and throat andmay cause pulmonary edema, which can result in serious injury <strong>or</strong> death. Repeated exposureto Anhydrous Ammonia may cause permanent lung damage.• Refer to the Material Safety Data Sheet (<strong>MS</strong>DS) f<strong>or</strong> Anhydrous Ammonia f<strong>or</strong> exposurecontrol/personal protection, handling/st<strong>or</strong>age, accidental release, first aid, and firefighting measure requirements.• Only use anhydrous ammonia with an appropriate ventilation system f<strong>or</strong> theinstrument, the exhaust from the f<strong>or</strong>eline pump, and the gas cylinder. Use appropriatesafety shutoff valves f<strong>or</strong> the anhydrous ammonia supply and interconnecting lines.You are responsible f<strong>or</strong> determining and implementing appropriate precautions whenusing anhydrous ammonia and f<strong>or</strong> compliance with all governmental regulations. You areresponsible f<strong>or</strong> understanding and adhering to all safe lab<strong>or</strong>at<strong>or</strong>y practices concerning theuse of toxic gases, including anhydrous ammonia.Check the checklist box: CI reagent gas (methane, isobutane <strong>or</strong> ammonia:99.99% pure), regulat<strong>or</strong>, and gas lines are installed.GC Carrier GasesHeliumHelium is required as a carrier gas f<strong>or</strong> the GC, with a minimum of 99.999% ultra-high purity, andless than 1.0 ppm each of water, oxygen, and total hydrocarbons. The minimum requirement isone 257 ft 3 tank with an Alltech regulat<strong>or</strong> #AL8111, <strong>or</strong> equivalent tank. Use a two-stage 0-100 psipressure regulat<strong>or</strong> with a stainless steel diaphragm.Check the checklist box: Helium (at least 99.999% pure), regulat<strong>or</strong>, and gas linesare installed.A carrier gas supply that has greater than 1 ppm oxygen <strong>or</strong> watermay significantly affect the perf<strong>or</strong>mance of the GC/<strong>MS</strong>. It mayalso damage components such as the capillary column,filaments, and multiplier. Verify that your gas suppliers usecontrolled tanks to ensure that purity standards are maintained. Ifyou purchase pure gases in contaminated tanks, your systemmay become contaminated and require costly and timeconsuming repairs.Carrier Gas FilterThe carrier gas filter protects your system from potential contamination and ensures optimumperf<strong>or</strong>mance. F<strong>or</strong> replacement procedures, please refer to the instructions enclosed with thefilter. The easy-to-remove gas filter cartridge combines three highly ads<strong>or</strong>ptive materials in onefilter to remove water, oxygen, and <strong>or</strong>ganic compounds. Install the carrier gas filter so that theindicat<strong>or</strong> is visible. Replace the filter when the indicat<strong>or</strong> shows that the filter is saturated, <strong>or</strong> afterone year of service, depending on which comes first.395414200:5 12 of 14 <strong>Pre</strong>-installation Instructions

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!