Unit Operation InstructionDDOP <strong>Probe</strong>3 TECHNICAL INFORMATION DDOP PROBEDimensions:Total, LxWxHSample Filter:MaterialFilter size640x330x220mmAISI 316L20µm ,102xØ50/40Process conditions:Available length for insertion in process400mmTemperature Max. 400°CDust load Max. 200 g/m 3Weight:Weight, dry:26 kgTemperatures:Ambient temperature: -10°C to 55°C 1Storage temperature: -15°C to 55°CEquipment must be protected against heatradiationConnections:Sample line connection:6 mm stainless steel SwagelokBlow Back hoses10 mm stainless steel SwagelokHose clampsSpecified according to actual sample gas hosediameter.Flange for mounting probeSee Drawing “DDOP <strong>Probe</strong>”Flange is supplied by FLSmidth AirloqCompressed air:Pressure:600 kPaRange 550-750 kPaConsumption:1 Nm3/h at 600 kPaQuality: 3-3-3 according to ISO 8573-1Maximum 5 mm (size) 5 mg/m3 particlesMinimum -20° water pressure dew point**Pressure dew point must be minimum -10°Cbelow minimum ambient temperature at anytime.Maximum 1 mg/m3 oil3.1 PHYSICAL DISTANCE BETWEEN EQUIPMENTThis information is covered by the system manual.1 <strong>Probe</strong> must be protected to prevent condensation and freezing.Drawing no: 53895-DDOP-450-20 Page 6 of 14