Double-Dry-nOn-cooled-Probe - Webshop, Gas Analysis Technology

Double-Dry-nOn-cooled-Probe - Webshop, Gas Analysis Technology

Double-Dry-nOn-cooled-Probe - Webshop, Gas Analysis Technology

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Unit Operation InstructionDDOP <strong>Probe</strong>Pressure:Temperature:Bar°C (degrees Celsius)For general use the following approximations can be used for conversion:Length: mm to inch factor 0,04Pressure: Bar to PSI (US) factor 14,5Temperature: °C to °F °F = °C × 1.8 + 322.2.3 DDOP PROBEDDOP<strong>Probe</strong>BBFilter<strong>Double</strong>-<strong>Dry</strong>-<strong>nOn</strong>-cOoled-<strong>Probe</strong>Extracts sample gas from a specific point in process.Blow-back cleaning air for filter cleaning.Filters sample gas from dust particles to protect the system.2.3 HOW TO READ THIS MANUALRead the instructions in this manual carefully before installing the system.FLSmidth Airloq A/S cannot accept any liability for damages due to nonobservanceof this manual.Sign:Before doing anything to the system, read warnings in section 2.4.This manual must be used in conjunction with the appendix. The document map in section2.1 shows an overview of the complete gas analysis system. This document covers theSDSP <strong>Probe</strong> only. For e.g. electrical wiring, the reader must use the appendix “Circuitdiagram”. All issues related to system performance must be found in the system manual.No part of this manual may be reproduced or transmitted in any form or by any means,electronic or printed, without the prior written permission of FLSmidth Airloq A/S. If thismanual is translated, the English version is to be considered as the original one.2.4 WARNING2.4.1 WARNING – HAZARDOUS VOLTAGES!Sign:All electrical installations must be in accordance with national and local regulations, andqualified personnel who are aware of these regulations must perform the electricalinstallation.Voltage must not be applied to the system until all electrical connections have been madeand checked and then only by qualified personnel who are aware of the risks involved.Any disconnection of the earthed conductor inside or outside the device or the release of theearthed conductor connection can make the device hazardous to life. Deliberatedisconnection is inadmissible/prohibited.All connections must be made in accordance with the drawings in this manual.Drawing no: 53895-DDOP-450-20 Page 4 of 14

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!