13.07.2015 Views

Agilent 7694E Headspace Sampler - Agilent Technologies

Agilent 7694E Headspace Sampler - Agilent Technologies

Agilent 7694E Headspace Sampler - Agilent Technologies

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

SpecificationsSample HandlingCarousel: holds twelve 10-mL or20-mLvials at near-ambient; shaking may be Off,Low, or High in 1-min increments from1–999 min.Incubation: vials are individually lifted upinto the heating zone for constant heatingtime (CHT) and immediately returned tothe carousel after injection.Vial heating: a vial can be heating duringthe GC run for the previous vial specifiedin the method.Analysis ConditionsVial heating: from 0–999 mins in 0.1-minincrements at temperatures from 40 to200 °C.Injection volume: 1-mL standard using agas sampling valve; a 3-mL loop is shippedwith the instrument.Valve and loop temperature range:50 to 200 °C.Transfer line to the GC, temperature range:50 to 220 °C. (The line is made of nickel.)Loop fill and loop equilibration times: settablefrom 0–99 mins in 0.01-min increments.(A short fill time permits injectionof a pressurized sample.)Injection time (carrier flows through loop):0–99 min in 0.01-min increments.Vial pressurization time: adjustable from0–99 min in 0.01-min increments. Pressurerange: 0–30 psi.<strong>Headspace</strong> MethodsFour methods may be stored in memoryand chained in sequence. A method mayspecify any sequential carousel positions.A method may include automatic vial heatingtemperature increments or time increments(1 °C or 1-min units) to determinethe optimum setting.GC cycle time: 1 to 999 min. (An <strong>Agilent</strong>GC-Ready signal can be sensed or ignored.)BCD output: provides vial number to an<strong>Agilent</strong> integrator.Physical SpecificationsPower required:Line voltage :Dimensions :300 VA maximum120 Vac single phase(± 10%), 50/60 Hz,4.5 A240 Vac single phase(± 10%), 50/60 Hz,2.5 Aheight, 43.5 cmwidth, 36 cmdepth, 39 cmweight, 27 KgEnvironmental: temperature, 5 to 40 °Chumidity, 0 to 95%altitude, 2,000m maxpollution degree, 2indoor useinstallation category, 2<strong>Agilent</strong> shall not be liable for errors contained herein or for incidentalor consequential damages in connection with the furnishing,performance, or use of this material.Information, descriptions, and specifications in this publicationare subject to change without notice.© <strong>Agilent</strong> <strong>Technologies</strong>, Inc., 2008Published in the USADecember 9, 20085965-9081E

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!