Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>GeneralInformationEnvironmentThe devices have been designed for indooruse at operating ambient temperatures rangingfrom +10°C to +30°C (from +50°F to +86°F).The storage temperature is ranging from 0°Cto 50°C (+32°F to +120°F).The operating ambient humidity is rangingfrom RH 40% to 70%. Storage humidity fromRH 10% to 90%The coils have a thermo sensor, which turnsthe stimulator off, when the coil surfacereaches a temperature of 41°C (106°F).Intended useSee the accompanying documentation and theUser Guide for the magnetic stimulatordevice.ContraindicationsSee the accompanying documentation and theUser Guide for the magnetic stimulatordevice.General WarningsSee the accompanying documentationand carefully read the followingwarningsWarnings• Do not use this equipment for anything elsethan it is intended for by the manufacturer.• The device is not compatible for use in anMR magnetic field. Please consult themanufacturer for available special solutionssuch as the MRi-B90 II system.• Rapid cortical stimulation can induceseizures. Ensure that appropriate safetymeasures are taken, before using theequipment.• To protect patients from excessiveexposure to magnetic gradients keep thenumber of stimulations as low as possible.• The device is not intended for use withanesthetic gases or any other flammablemedia – danger of electrical ignition.• The operator must be protected againstlong-term magnetic fields (e.g. by using aholding device as the Flexible Arm).• Hearing protection is recommended if thecoil is used near the head or whenoperating with more than 100 stimuli aday.• Not to be used on small children.• Keep out of reach of children.• Precautions should be taken whenstimulating patients with suspected ordiagnosed labile or hypertensive bloodpressure.• The field produced by this device candamage a cochlear implant, cardiacpacemaker and implanted electronicdevices.• The MagPro must only be used under theconstant supervision of qualified medicalpersonnel, only on patients who are notanaesthetized and only for short term use.6 www.<strong>MagVenture</strong>.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!