Magnetic Stimulation Accessories CatalogueEMG AccessoriesMEP Monitor, 1 channel EMG amplifier• 1 channel EMG amplifier to be mountedon the back of the MagPro system.• Measurement of Motor Evoked Potentials(MEP).• Specially designed for determination anddocumentation of Motor Threshold.• Includes MEP Electrode Cable and onepack of Surface Electrodes (12pcs.)Technical DataDimensionsWeightNumber of InputsSound(HxWxD:) 184 x 94 x 40mm0.7kg1 input protected against electrostaticdischarge. Balanced inputs.1 pc. 5-pole DIN 240° connector forelectrode cableOutput for external loudspeaker,3.5mm jack.Patient Safety EMG channel galvanically isolated1.5 kV RMSInput Impedance 200 MΩ // 100 pF (balanced), >1000MΩ // 50 pF (common mode)Noise LevelCommon ModeRejection RatioIsolation ModeRejection RatioSensitivity FactorsTime ScalesTrigger ModeLower FrequencyLimits (-3dB): DSPUpper FrequencyLimits (-3dB): DSPAnti-AliasingSamplingTypical 0.6 μVrms at bandwidth2 Hz to 20 kHz and shorted inputFrom surface electrode, throughcable and amplifier: >55 dB.Direct: >100 dBFrom input to power ground:>160 dB100, 200, 500 μV/Div,1, 2, 5, 10 mV/Div1, 2, 5, 8, 10 ms/DivLevel, Autotrig on stim1, 2, 5, 10, 20, 50, 100 Hz,1, 2, 5, 10, 20 kHz,20 kHz (-3 dB), 1 st order100 ks/s, 16 bitOrdering Number 9016C070-50 www.MagVenture.com
Magnetic Stimulation Accessories CatalogueElectrode cable and Electrodes for MEP MonitorSurface Electrodes (pack of 12pcs.)Electrode size28 x 20 mmSensor materialSilver / silver chlorideGel systemSolid gelSensor area 490 mm 2Cable length50 cmConnector1.5mm female TPOrdering Number 9016S020-• Pack of Pre-gelled Surface electrodes(12pcs.) with 1.5mm touch-proofconnector. Used for MEP recordings asActive, Reference and Ground electrode.Shielded Electrode cableCable length3 mConnector for MEP Monitor 5-pole DIN 240°Connector for electrodes 1.5mm male TP (3 pcs.)Ordering Number 9016C081-• Shielded Electrode cable for MEP Monitorwith 1.5mm touch-proof connectors forActive, Reference and Ground electrodes.www.MagVenture.com 51
- Page 2 and 3: Magnetic Stimulation Accessories Ca
- Page 6 and 7: Magnetic Stimulation Accessories Ca
- Page 8 and 9: Magnetic Stimulation Accessories Ca
- Page 10 and 11: Symbols andWarningsSymbolsSN xxxP/N
- Page 12 and 13: Magnetic Stimulation Accessories Ca
- Page 14 and 15: Magnetic Stimulation Accessories Ca
- Page 16 and 17: Magnetic Stimulation Accessories Ca
- Page 18 and 19: Magnetic Stimulation Accessories Ca
- Page 20 and 21: Magnetic Stimulation Accessories Ca
- Page 22 and 23: Magnetic Stimulation Accessories Ca
- Page 24 and 25: Magnetic Stimulation Accessories Ca
- Page 26 and 27: Magnetic Stimulation Accessories Ca
- Page 28 and 29: Magnetic Stimulation Accessories Ca
- Page 30 and 31: Magnetic Stimulation Accessories Ca
- Page 32 and 33: Magnetic Stimulation Accessories Ca
- Page 34 and 35: Magnetic Stimulation Accessories Ca
- Page 36 and 37: Magnetic Stimulation Accessories Ca
- Page 38 and 39: Magnetic Stimulation Accessories Ca
- Page 40 and 41: Magnetic Stimulation Accessories Ca
- Page 42 and 43: Magnetic Stimulation Accessories Ca
- Page 44 and 45: Magnetic Stimulation Accessories Ca
- Page 46 and 47: Magnetic Stimulation Accessories Ca
- Page 48 and 49: Magnetic Stimulation Accessories Ca
- Page 52: MagPro and accessories are manufact
Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>EMG <strong>Accessories</strong>MEP Monitor, 1 channel EMG amplifier• 1 channel EMG amplifier to be mountedon the back of the MagPro system.• Measurement of Motor Evoked Potentials(MEP).• Specially designed for determination anddocumentation of Motor Threshold.• Includes MEP Electrode Cable and onepack of Surface Electrodes (12pcs.)Technical DataDimensionsWeightNumber of InputsSound(HxWxD:) 184 x 94 x 40mm0.7kg1 input protected against electrostaticdischarge. Balanced inputs.1 pc. 5-pole DIN 240° connector forelectrode cableOutput for external loudspeaker,3.5mm jack.Patient Safety EMG channel galvanically isolated1.5 kV RMSInput Impedance 200 MΩ // 100 pF (balanced), >1000MΩ // 50 pF (common mode)Noise LevelCommon ModeRejection RatioIsolation ModeRejection RatioSensitivity FactorsTime ScalesTrigger ModeLower FrequencyLimits (-3dB): DSPUpper FrequencyLimits (-3dB): DSPAnti-AliasingSamplingTypical 0.6 μVrms at bandwidth2 Hz to 20 kHz and shorted inputFrom surface electrode, throughcable and amplifier: >55 dB.Direct: >100 dBFrom input to power ground:>160 dB100, 200, 500 μV/Div,1, 2, 5, 10 mV/Div1, 2, 5, 8, 10 ms/DivLevel, Autotrig on stim1, 2, 5, 10, 20, 50, 100 Hz,1, 2, 5, 10, 20 kHz,20 kHz (-3 dB), 1 st order100 ks/s, 16 bitOrdering Number 9016C070-50 www.<strong>MagVenture</strong>.com